Entity Name: | SUNSHINE VALET, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
SUNSHINE VALET, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 15 Jul 2014 (11 years ago) |
Document Number: | L14000111163 |
FEI/EIN Number |
47-1507613
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 610 E Zack Street, Tampa, FL, 33602, US |
Mail Address: | 610 E Zack Street, Tampa, FL, 33602, US |
ZIP code: | 33602 |
County: | Hillsborough |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
GREMER BRIAN | Managing Member | 610 E Zack Street, Tampa, FL, 33602 |
STARK KRISTEN J | Manager | 10129 WHITE TROUT LANE, TAMPA, FL, 33618 |
MONROE NEAL | Manager | 610 E Zack Street, Tampa, FL, 33602 |
DILLON BRIAN | Manager | 610 E Zack Street, Tampa, FL, 33602 |
STARK KRISTEN J | Agent | 610 E Zack Street, Tampa, FL, 33602 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2022-05-01 | 610 E Zack Street, Tampa, FL 33602 | - |
CHANGE OF MAILING ADDRESS | 2022-05-01 | 610 E Zack Street, Tampa, FL 33602 | - |
REGISTERED AGENT ADDRESS CHANGED | 2022-05-01 | 610 E Zack Street, Tampa, FL 33602 | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J22000019390 | TERMINATED | 1000000910910 | HILLSBOROU | 2021-12-22 | 2032-01-12 | $ 3,275.76 | STATE OF FLORIDA, DEPARTMENT OF REVENUE, TAMPA SERVICE CENTER, 5483 W WATERS AVE STE 1210, TAMPA FL336341236 |
Name | Date |
---|---|
ANNUAL REPORT | 2024-05-01 |
ANNUAL REPORT | 2023-05-01 |
ANNUAL REPORT | 2022-05-01 |
ANNUAL REPORT | 2021-05-01 |
ANNUAL REPORT | 2020-06-29 |
ANNUAL REPORT | 2019-05-01 |
ANNUAL REPORT | 2018-05-01 |
ANNUAL REPORT | 2017-05-01 |
ANNUAL REPORT | 2016-05-01 |
ANNUAL REPORT | 2015-05-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344145867 | 0420600 | 2019-07-10 | 5700 SADDLEBROOK WAY, WESLEY CHAPEL, FL, 33543 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1414579 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100022 D01 |
Issuance Date | 2019-12-19 |
Abatement Due Date | 2020-01-09 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2020-01-15 |
Nr Instances | 1 |
Nr Exposed | 7 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.22(d)(1): Walking-working surfaces were not maintained in a safe condition: a) On or about July 10, 2019, at the jobsite, employees were exposed to trip and fall hazards, in that a raised section of decking under the door of the valet closet leading outside was not level with the actual floor. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100305 A02 IX |
Issuance Date | 2019-12-19 |
Abatement Due Date | 2019-12-30 |
Current Penalty | 3978.0 |
Initial Penalty | 6630.0 |
Final Order | 2020-01-15 |
Nr Instances | 1 |
Nr Exposed | 7 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(a)(2)(ix): All lamps for general illumination shall be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded: a. The overhead florescent lighting bulbs in the valet closet did not have sleeves or other means of protection from accidental contact. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100141 A03 I |
Issuance Date | 2019-12-19 |
Abatement Due Date | 2020-02-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-01-15 |
Nr Instances | 1 |
Nr Exposed | 7 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: a) On or about July 10, 2019, at the jobsite, the roof of the building called the valet closet leaks when it rains. The water comes through the ceiling and down the walls. Containers are placed on the floor to catch the water and the room has a bad odor. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100303 B02 |
Issuance Date | 2019-12-19 |
Abatement Due Date | 2019-12-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-01-15 |
Nr Instances | 1 |
Nr Exposed | 7 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about July 10, 2019, at the jobsite, various surge protectors, including but not limited to, the APC Surge Arrest Professional surge protector in the valet closet was not secured or mounted in place and multiple power cords were plugged into them. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19100305 G01 IV A |
Issuance Date | 2019-12-19 |
Abatement Due Date | 2019-12-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-01-15 |
Nr Instances | 1 |
Nr Exposed | 7 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about July 10, 2019, at the jobsite, extension cords in the valet closet were continuously connected to equipment and the wall outlets. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3947138404 | 2021-02-05 | 0455 | PPS | 1214 W Cass St, Tampa, FL, 33606-1342 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1132477100 | 2020-04-09 | 0455 | PPP | 1214 CASS ST, TAMPA, FL, 33606-1342 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 01 Mar 2025
Sources: Florida Department of State