Search icon

OCEAN ROOFING OF FLORIDA LLC - Florida Company Profile

Company Details

Entity Name: OCEAN ROOFING OF FLORIDA LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

OCEAN ROOFING OF FLORIDA LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 20 Jun 2014 (11 years ago)
Document Number: L14000099288
FEI/EIN Number NOT APPLICABLE

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 14422 Shoreside Way, SUITE 110-157, WINTER GARDEN, FL, 34787, US
Mail Address: 14422 Shoreside Way, SUITE 110-157, WINTER GARDEN, FL, 34787, US
ZIP code: 34787
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PROSPERITY UNITED OF CFL, INC Agent -
WESTERN JOE A Auth 14422 Shoreside Way, winter garden, FL, 34787

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2024-02-08 PROSPERITY UNITED OF CFL, INC -
CHANGE OF PRINCIPAL ADDRESS 2023-04-13 14422 Shoreside Way, SUITE 110-157, WINTER GARDEN, FL 34787 -
CHANGE OF MAILING ADDRESS 2023-04-13 14422 Shoreside Way, SUITE 110-157, WINTER GARDEN, FL 34787 -
REGISTERED AGENT ADDRESS CHANGED 2023-04-13 3425 Laurel Drive, Mount Dora, FL 32757 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J17000287724 TERMINATED 16-8019-CI PINELLAS COUNTY CIRCUIT CIVIL 2017-05-09 2022-05-25 $25,036.49 GULFSIDE SUPPLY, INC., 2900 EAST 7TH AVENUE, TAMPA, FL 33605

Documents

Name Date
ANNUAL REPORT 2025-02-13
ANNUAL REPORT 2024-02-08
ANNUAL REPORT 2023-04-13
AMENDED ANNUAL REPORT 2022-12-26
ANNUAL REPORT 2022-04-28
ANNUAL REPORT 2021-03-29
ANNUAL REPORT 2020-06-18
AMENDED ANNUAL REPORT 2019-12-06
ANNUAL REPORT 2019-04-30
AMENDED ANNUAL REPORT 2018-12-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343449179 0420600 2018-09-06 4575 EMERSON PARK DRIVE, ORLANDO, FL, 32839
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2018-09-07
Emphasis L: FORKLIFT, L: FALL, P: FALL
Case Closed 2022-10-31

Related Activity

Type Complaint
Activity Nr 1371926
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2018-11-28
Abatement Due Date 2018-12-06
Current Penalty 2439.0
Initial Penalty 4878.0
Final Order 2019-01-16
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about 09/06/2018, at the job site, employees were not provided hard hats while roofing material was being thrown from the roof of a 3 story building into trash container that was being lifted by an aerial lift. The employees on the ground were picking up debris & trash directly under the area where the old roofing materials were being thrown into the container. b. On or about 09/07/2018, at the job site, employees were not provided hard hats while roofing material was being thrown from the roof of a 3 story building into trash container that was being lifted by an aerial lift. The employees on the ground were picking up debris & trash directly under the area where the old roofing materials were being thrown into the container.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G03 IV
Issuance Date 2018-11-28
Abatement Due Date 2018-12-06
Current Penalty 2845.5
Initial Penalty 5691.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(3)(iv): Vertical lifelines, independent support lines, and suspension ropes were attached to the same point on the scaffold or personal fall arrest system: a. On or about 09/06/18, on the roof of building 4575, employees attached two lifelines to a single temper roof anchor.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2018-11-28
Abatement Due Date 2018-12-06
Current Penalty 2845.5
Initial Penalty 5691.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a. On or about 09/06/2018, at the jobsite, the operator of JLG aerial lift was not wearing a safety harness or body belt while operating the lift.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2018-11-28
Abatement Due Date 2018-12-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-16
Nr Instances 2
Nr Exposed 14
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a. On or about 09/06/2018, at the jobsite, untrained employees were allowed to operate a JLG aerial lift. b. On or about 09/07/2018, at the jobsite, untrained employees were allowed to operate a JLG aerial lift.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19260502 D16 III
Issuance Date 2018-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a. On or about 9/7/2018, at the jobsite, an employee operating an aerial lift used rope as safety lanyard for his personal fall arrest system and the rope was rigged where the employee could fall more than 6 feet.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2018-11-28
Abatement Due Date 2018-12-06
Current Penalty 2032.5
Initial Penalty 4065.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 14
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee: a. On or about 09/06/2018, at the jobsite, the Guardian temper roof anchors being used by employees doing roofing work were not installed per the manufacture's recommendation, in that, the required number of fasteners (12) were not used.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2018-11-28
Abatement Due Date 2018-12-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-16
Nr Instances 2
Nr Exposed 14
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a. On or about 09/06/2018, at the jobsite, employees working on a 5:12 pitched roof were not trained on fall protection and the employees were exposed to a 30 foot fall hazard. b. On or about 09/07/2018, at the jobsite, employees working on a 5:12 pitched roof were not trained on fall protection and the employees were exposed to a 30 foot fall hazard.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-11-28
Abatement Due Date 2018-12-06
Current Penalty 2845.5
Initial Penalty 5691.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 14
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about 08/21/2018, at the job site - the rails of the ladder used to access the roof of the building did not extend at least 3 foot above the upper landing surface, exposing the employees to about an 10 foot fall hazard.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19261060 A01
Issuance Date 2018-11-28
Abatement Due Date 2018-12-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 14
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1): The employer did not provide a training program for each employee using ladders as necessary, enabling each employee to recognize hazards related to ladders and the procedures to be followed to minimize these hazards. a. On or about 08/21/2018, at the job site - employees required to use a ladder to access the roof of the building were not provided with training. The employees were exposed to about a 10 foot fall hazard.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2018-11-28
Abatement Due Date 2018-12-06
Current Penalty 28454.0
Initial Penalty 56908.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 14
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about 09/06/2018, at the jobsite, employees doing residential roofing work on a 5:12 pitch roof were not protected from falling approximately 30 feet to the ground below. OCEAN ROOFING OF FLORIDA LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1114746, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 06/13/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 3140 57TH AVE CIRCLE EAST, BRADENTON, FL 34203.
Citation ID 03001
Citaton Type Other
Standard Cited 19260502 D21
Issuance Date 2018-11-28
Abatement Due Date 2018-12-06
Current Penalty 228.0
Initial Penalty 456.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a. On or about 09/06/2018, at the jobsite, the fall protection equipment provided to employees was not inspected prior to the equipment being installed and used on a 5:12 pitch roof.
343404943 0420600 2018-08-21 LOUISA MAY LN. AND CONCORD LANDING DR., ORLANDO, FL, 32839
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2018-08-21
Emphasis L: FALL
Case Closed 2023-02-07

Related Activity

Type Complaint
Activity Nr 1371926
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2018-11-13
Current Penalty 3880.0
Initial Penalty 7760.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 9
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about 08/21/2018, at the job site - employees working from 5:12 roof were exposed to 34 feet fall hazards while conducting roofing work, in that, fall protection was not used. OCEAN ROOFING OF FLORIDA LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1114746, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 06/13/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 3140 57TH AVE CIRCLE EAST, BRADENTON, FL 34203.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-11-13
Abatement Due Date 2018-11-26
Current Penalty 1940.0
Initial Penalty 3880.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about 08/21/2018, at the job site - the rails of the ladder used to access the second floor of the building did not extend at least 3 foot above the upper landing surface, exposing the employees to about a 10 feet fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2018-11-13
Abatement Due Date 2018-11-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a. On or about 08/21/2018, at the job site - employees conducting roofing work were exposed to a 34 feet fall hazards, and the employer did not provided written certification of fall protection training.
Citation ID 02002
Citaton Type Other
Standard Cited 19261060 A01
Issuance Date 2018-11-13
Abatement Due Date 2018-11-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-01-16
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1): The employer did not provide a training program for each employee using ladders as necessary, enabling each employee to recognize hazards related to ladders and the procedures to be followed to minimize these hazards. a. On or about 08/21/2018, at the job site - employees required to use a ladder to access the roof of the building were not provided with training. The employees were exposed to about a 10 feet fall hazard.
341147460 0420600 2015-12-30 3140 57TH AVE CIRCLE EAST, BRADENTON, FL, 34203
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-12-30
Emphasis L: FALL, P: FALL
Case Closed 2019-07-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-05-16
Abatement Due Date 2016-05-26
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2016-06-13
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at 3140 57th Avenue Circle east located in Bradenton, as observed on or about 30 December, 2015. Employees were installing roofing materials on a 5:12 pitch roof without the use of fall protection. Employees were exposed to an approximate 8 foot 4 inch fall.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
8422778506 2021-03-09 0491 PPP 14422 Shoreside Way Ste 110-157, Winter Garden, FL, 34787-4938
Loan Status Date 2023-07-28
Loan Status Paid in Full
Loan Maturity in Months 40
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 80345
Loan Approval Amount (current) 29582
Undisbursed Amount 0
Franchise Name -
Lender Location ID 58771
Servicing Lender Name Legacy Bank
Servicing Lender Address 101 W Main St, HINTON, OK, 73047
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Winter Garden, ORANGE, FL, 34787-4938
Project Congressional District FL-10
Number of Employees 5
NAICS code 238160
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 58771
Originating Lender Name Legacy Bank
Originating Lender Address HINTON, OK
Gender Unanswered
Veteran Unanswered
Forgiveness Amount -
Forgiveness Paid Date -

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
3364782 Intrastate Non-Hazmat 2019-12-03 - - 1 1 Private(Property)
Legal Name OCEAN ROOFING OF FLORIDA LLC
DBA Name -
Physical Address 8172 COMMON TEAL CT , WINTER GARDEN, FL, 34787-4939, US
Mailing Address 8172 COMMON TEAL CT , WINTER GARDEN, FL, 34787-4939, US
Phone (407) 575-0022
Fax -
E-mail OCEANROOFINGLLC@GMAIL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 1
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 1
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 1
Vehicle Maintenance BASIC Roadside Performance measure value 23
Total Number of Vehicle Inspections for the measurement period 1
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 1
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 1
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 1
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Inspections

Unique report number of the inspection 2545004746
State abbreviation that indicates the state the inspector is from FL
The date of the inspection 2023-12-20
ID that indicates the level of inspection Walk-around
State abbreviation that indicates where the inspection occurred FL
Time weight of the inspection 1
Number of Out-Of-Service violations related to Driver 0
Number of Out-Of-Service violations related to vehicle 1
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 1
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit STRAIGHT TRUCK
Description of the make of the main unit FRHT
License plate of the main unit P1959C
License state of the main unit FL
Vehicle Identification Number of the main unit 1FVHCYBS9CDBN9501
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Vehicle Maintenance BASIC inspection Y
Total number of BASIC violations 5
Number of Unsafe Driving BASIC violations 0
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 1
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 4
Number of Hazardous Materials Compliance BASIC violations 0

Violations

The date of the inspection 2023-12-20
Code of the violation 3939
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 1
The description of a violation Inoperable Required Lamp
The description of the violation group Clearance Identification Lamps/Other
The unit a violation is cited against Vehicle main unit
The date of the inspection 2023-12-20
Code of the violation 39375COOS
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 8
The time weight that is assigned to a violation 1
The description of a violation Tire-other tread depth less than 1/32 of inch measured in 2 adjacent major tread grooves 3 separate locations 8 inches apart
The description of the violation group Tires
The unit a violation is cited against Vehicle main unit
The date of the inspection 2023-12-20
Code of the violation 39375C
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 8
The time weight that is assigned to a violation 1
The description of a violation Tire-other tread depth less than 2/32 of inch measured in a major tread groove
The description of the violation group Tires
The unit a violation is cited against Vehicle main unit
The date of the inspection 2023-12-20
Code of the violation 393110B
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 3
The time weight that is assigned to a violation 1
The description of a violation Insufficient tiedowns to prevent forward movement for load not blocked by headerboard bulkhead or other cargo
The description of the violation group Tiedown
The unit a violation is cited against Vehicle main unit
The date of the inspection 2023-12-20
Code of the violation 39145B
Name of the BASIC Driver Fitness
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 1
The time weight that is assigned to a violation 1
The description of a violation Expired medical examiner's certificate
The description of the violation group Medical Certificate
The unit a violation is cited against Driver

Date of last update: 03 May 2025

Sources: Florida Department of State