Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2014-11-05
|
Emphasis |
N: SILICA
|
Case Closed |
2018-11-13
|
Related Activity
Type |
Complaint |
Activity Nr |
919349 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1008276 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-26 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about November 5, 2014, at the above addressed jobsite, the employer did not affix guards on a bridge saw, that has rotating saw and a nip point, which is used by employees to cut granite slabs during granite countertop fabrication. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2015-04-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. On or about November 5, 2014, at the above addressed worksite, employees were performing granite countertop fabrication tasks in a facility where dust, containing silica, covered work surfaces, eating surfaces, and equipment. |
|
Citation ID |
02002A |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about November 5, 2014, at the above addressed jobsite, the employer did not establish a written respiratory program with worksite specific procedures for employees performing granite countertop fabrication tasks such as, but not limited to, grinding and cutting granite stone, while required to wear tight fitting (filtering facepiece) respirators. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19100134 E01 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about November 5, 2014, at the above addressed jobsite, employees performing granite countertop fabrication tasks such as, but not limited to, grinding and cutting granite stone, without having a medical evaluation to determine if they are medically able to perform these tasks while wearing a respirator. |
|
Citation ID |
02002C |
Citaton Type |
Other |
Standard Cited |
19100134 F02 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: On or about November 5, 2014, at the above addressed jobsite, the employer did not conduct fit testing for employees required to wear tight-fitting (filtering facepiece) respirators, while performing concrete restoration tasks, such as, but not limited to, grinding granite slabs to create countertops. |
|
Citation ID |
02002D |
Citaton Type |
Other |
Standard Cited |
19100134 K01 VII |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(1)(vii): The employer did not ensure that each user could demonstrate knowledge of the general requirements of the standard: On or about November 5, 2015, at the above addressed jobsite, the employer did not ensure that employees who are required to wear respirators during granite fabrication tasks such as grinding granite, were able to properly inspect, check the seals of the respirator, know why proper fit is necessary, and how maintenance could compromise the protective effect of the respirator. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about November 5, 2014, at the above addressed jobsite, the employer did not develop a hazard communication program for employees who use and handle hazardous materials such as, but not limited to, benzoyl peroxide, styrene, and silica, during granite countertop fabrication operations. |
|
|