Entity Name: | THE ROOF DUCK, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
THE ROOF DUCK, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 19 Feb 2014 (11 years ago) |
Date of dissolution: | 25 Sep 2020 (5 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 25 Sep 2020 (5 years ago) |
Document Number: | L14000029073 |
FEI/EIN Number |
46-4867929
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 3948 3rd Street South, Jacksonville Beach, FL, 32250, US |
Mail Address: | 3948 3rd Street South, Jacksonville Beach, FL, 32250, US |
ZIP code: | 32250 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Alan Ross, Jr. | Owne | 3948 3rd Street South, Jacksonville Beach, FL, 32250 |
ROSS ALAN JR. | Agent | 3948 3rd Street South, Jacksonville Beach, FL, 32250 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G14000117236 | RESCUE ROOFING | EXPIRED | 2014-11-21 | 2019-12-31 | - | 3948 3RD ST S #195, JACKSONVILLE BEACH, FL, 32250 |
G14000069917 | FORD ROOFING SYSTEMS | EXPIRED | 2014-07-07 | 2019-12-31 | - | 183 LANDRUM LANE, SUITE 104, PONTE VEDRA BEACH, FL, 32082 |
G14000047168 | NORTH FLORIDA ROOFING & REPAIR | EXPIRED | 2014-05-13 | 2019-12-31 | - | 221 NORTH ARLINGTON ROAD, JACKSONVILLE, FL, 32211 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2020-09-25 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2015-04-28 | 3948 3rd Street South, Jacksonville Beach, FL 32250 | - |
CHANGE OF MAILING ADDRESS | 2015-04-28 | 3948 3rd Street South, Jacksonville Beach, FL 32250 | - |
REGISTERED AGENT NAME CHANGED | 2015-04-28 | ROSS, ALAN, JR. | - |
REGISTERED AGENT ADDRESS CHANGED | 2015-04-28 | 3948 3rd Street South, Jacksonville Beach, FL 32250 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2019-04-02 |
ANNUAL REPORT | 2018-04-02 |
ANNUAL REPORT | 2017-01-30 |
ANNUAL REPORT | 2016-04-14 |
ANNUAL REPORT | 2015-04-28 |
Florida Limited Liability | 2014-02-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341132876 | 0419700 | 2015-12-17 | 274 AND 286 1ST STREET, JACKSONVILLE BEACH, FL, 32250 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2015-12-24 |
Current Penalty | 816.0 |
Initial Penalty | 1360.0 |
Final Order | 2016-01-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, was not protected by protective helmets: a. On December 17, 2015, two employees working on the ground to support roofing activities are not wearing hard hats, exposing themselves to an overhead hazard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2015-12-24 |
Current Penalty | 1020.0 |
Initial Penalty | 1700.0 |
Final Order | 2016-01-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On December 17, 2015, on the 5:12 pitch roof, two workers installing sheet metal roofing are not protected from a 29 feet fall hazard by the use of an adequate fall protection system. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B22 |
Issuance Date | 2015-12-24 |
Current Penalty | 1020.0 |
Initial Penalty | 1700.0 |
Final Order | 2016-01-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(22): 29 CFR 1926.1053(b)(2): Employee(s) using ladders were carrying object or loads that could cause them to lose balance and fall: a. On December 17, 2015, workers are carrying large pieces of sheet metal when using the extension ladder to access the roof, exposing themselves to a 20 feet to 29 feet fall hazard. |