Search icon

CEDILLO'S PROFESSIONAL PAINTING, LLC - Florida Company Profile

Company Details

Entity Name: CEDILLO'S PROFESSIONAL PAINTING, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

CEDILLO'S PROFESSIONAL PAINTING, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Dec 2013 (11 years ago)
Date of dissolution: 25 Sep 2015 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (9 years ago)
Document Number: L13000166706
FEI/EIN Number NOT APPLICABLE

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 219 1 STREET, SANTA ROSA BEACH, FL, 32459, US
Mail Address: 219 1 STREET, SANTA ROSA BEACH, FL, 32459, US
ZIP code: 32459
County: Walton
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
JIMENEZ CRUZ ANDRES M Manager 219 1 STREET, SANTA ROSA BEACH, FL, 32459
CASTELLANOS JORGE Agent 219 1 STREET, SANTA ROSA BEACH, FL, 32459

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -
CHANGE OF PRINCIPAL ADDRESS 2014-03-27 219 1 STREET, SANTA ROSA BEACH, FL 32459 -
CHANGE OF MAILING ADDRESS 2014-03-27 219 1 STREET, SANTA ROSA BEACH, FL 32459 -
REGISTERED AGENT NAME CHANGED 2014-03-27 CASTELLANOS, JORGE -
REGISTERED AGENT ADDRESS CHANGED 2014-03-27 219 1 STREET, SANTA ROSA BEACH, FL 32459 -
LC DISSOCIATION MEM 2014-01-21 - -

Documents

Name Date
AMENDED ANNUAL REPORT 2014-12-08
AMENDED ANNUAL REPORT 2014-03-27
ANNUAL REPORT 2014-01-28
CORLCDSMEM 2014-01-21
Florida Limited Liability 2013-12-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345273742 0418600 2021-04-27 1424 BLACKBIRD COURT LOT 294 SWEETBAY, PANAMA CITY, FL, 32405
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2021-04-27
Emphasis L: FALL
Case Closed 2023-09-19

Related Activity

Type Referral
Activity Nr 1761094
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 3700.0
Initial Penalty 5461.0
Final Order 2021-07-19
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) At 1424 Blackbird Court, Lot 294 Sweetbay (Rear of House), Panama City, Florida: On or about April 27, 2021 and at times prior; the employer allowed his employees to perform painting activities from a ladder jack scaffold without ensuring the scaffold had a ladder for employees to use to get on and off the scaffold exposing his employee to a fall hazard of 22 feet 6 inches to the ground below.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-07-19
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) At 1424 Blackbird Court, Lot 294 Sweetbay (Rear of House), Panama City, Florida: On or about April 27, 2021 and at times prior; the employer allowed his employees to perform painting activities from a ladder jack scaffold without using fall protection properly exposing his employee to a fall hazard of 22 feet 6 inches to the ground below. b) At 1424 Blackbird Court, Lot 294 Sweetbay (West Side of House), Panama City, Florida: On or about April 27, 2021 and at times prior; the employer allowed his employee to perform painting activities from a ladder jack scaffold without using fall protection exposing his employee to a fall hazard of 15 feet 6 inches to the ground below.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260452 K01
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m): a) At 1424 Blackbird Court, Lot 294 Sweetbay (Rear of House), Panama City, Florida: On or about April 27, 2021 and at times prior; the employer allowed his employees to perform painting activities from a ladder jack scaffold raised to a height greater than 20 feet exposing his employee to a fall hazard of 22 feet 6 inches to the ground below.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) At 1424 Blackbird Court, Lot 294 Sweetbay (Rear of House), Panama City, Florida: On or about April 27, 2021 and at times prior; the employer allowed his employees to perform painting activities from a ladder jack scaffolds without first ensuring his employees were trained on the hazards associated with scaffolds such as erecting, dismantling and the requirement to use fall protection exposing his employee to a fall hazard of up to 22 feet 6 inches to the ground below.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 3000.0
Initial Penalty 4681.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 1424 Blackbird Court, Lot 294 Sweetbay, Panama City, Florida: On or about April 24, 2021 and at times prior; the employer allowed his employee to perform painting prepping activities from a roof without fall protection exposing his employee to a fall hazard of 12 feet 7 inches to the ground below.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) At 1424 Blackbird Court, Lot 294 Sweetbay, Panama City, Florida: On or about April 24, 2021 and at times prior; the employer allowed his employee to perform painting prepping activities from a roof without first ensuring his employee was trained on the hazards associated with falls to include but not limited to setting up and inspecting fall protection exposing his employee to a fall hazard of 12 feet 7 inches to the ground below.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 3000.0
Initial Penalty 5461.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) At 1424 Blackbird Court, Lot 294 Sweetbay (Rear of House), Panama City, Florida: On or about April 27, 2021 and at times prior; the employer allowed his employees to perform painting activities from a ladder jack scaffold and the ladders used to support the scaffolds were not set up as required by the regulations exposing his employee to a fall hazard of 22 feet 6 inches to the ground below.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) At 1424 Blackbird Court, Lot 294 Sweetbay, Panama City, Florida: On or about April 24, 2021 and at times prior; the employer allowed his employee to work from a six foot a-frame ladder on a roof leaned against the second floor wall exposing his employee to a fall hazard of 12 feet 7 inches to the ground below.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2021-05-14
Abatement Due Date 2021-05-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a) At 1424 Blackbird Court, Lot 294 Sweetbay, Panama City, Florida: On or about April 24, 2021 and at times prior; the employer allowed his employee to work from a six foot a-frame ladder on a low slope roof leaned against the second floor wall exposing his employee to a fall hazard of 12 feet 7 inches to the ground below.
Citation ID 02001
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2021-05-14
Current Penalty 2000.0
Initial Penalty 3901.0
Final Order 2021-07-19
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: a) At 1424 Blackbird Court, Lot 294 Sweetbay, Panama City, Florida: On April 24, 2021 ; the employer failed to report an in-patient hospitalization of an employee who suffered work related injuries due to a fall to OSHA within 24 hours .
340071323 0419700 2014-11-08 202 CANNONBALL LANE, SANTA ROSA BEACH, FL, 32459
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-11-08
Emphasis L: FALL, P: FALL
Case Closed 2018-03-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-11-17
Current Penalty 2640.0
Initial Penalty 2640.0
Final Order 2014-12-15
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about November 8, 2014, an employee using a Makita 5007F handsaw to cut plywood pieces was not wearing safety glasses, exposing himself to being hit by flying debris. b. On or about November 8, 2014, an employee using a Hitachi NR83A2 pneumatic nail gun to nail plywood pieces was not wearing safety glasses, exposing himself to being hit by nails or flying debris.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260100 A
Issuance Date 2014-11-17
Current Penalty 5280.0
Initial Penalty 5280.0
Final Order 2014-12-15
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about November 8, 2014, employees at the jobsite were not wearing protective helmets, exposing themselves to overhead hazards. The Cedillo's Professional Painting, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.100(a), which was contained in OSHA inspection number 979532, citation number 01, item number 001 and was affirmed as a final order on August 13, 2014, with respect to a workplace located at east Royal Fern way, Santa Rosa Beach, Florida 32459.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2014-11-17
Current Penalty 5280.0
Initial Penalty 5280.0
Final Order 2014-12-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 8, 2014, an employee performing framing operations was not protected from a 10-foot 2-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection. The Cedillo's Professional Painting, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 979532, citation number 01, item number 003 and was affirmed as a final order on August 13, 2014, with respect to a workplace located at east Royal Fern way, Santa Rosa Beach, Florida 32459.
339795320 0419700 2014-06-05 EAST ROYAL FERN WAY LOT 21, SANTA ROSA BEACH, FL, 32459
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-06-05
Emphasis L: FALL, P: FALL
Case Closed 2018-11-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-07-14
Current Penalty 4200.0
Initial Penalty 4200.0
Final Order 2014-08-14
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about June 5, 2014, on the east side of a framed house, an employee working beneath employees building a framed structure was not wearing a hard hat, exposing the employee to the hazard of being struck by falling debris. a. On or about June 5, 2014, on the south side of a framed house, an employee working beneath employees building a framed structure was not wearing a hard hat, exposing the employee to the hazard of being struck by falling debris.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2014-07-14
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-14
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. On or about June 5, 2014, on the north side of the house, an employee installing framing was using 2 inch by 10 inch wood planks as a scaffold platform, exposing the employee to an 8 feet, 5 inch fall hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2014-07-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-14
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about June 5, 2014, on the north side of the house, the carpenter's scaffold did not have adequate firm foundations, exposing employees to a 8 feet 4 inch fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-07-14
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-08-14
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a. On or about June 5, 2014, on the second level of a framed house, employees installing framing material were not protected from a 16 feet fall hazard by the use of a personal fall protection system.