Search icon

T. ESCOBAR CONSTRUCTION LLC

Company Details

Entity Name: T. ESCOBAR CONSTRUCTION LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Company
Status: Active
Date Filed: 21 Nov 2013 (11 years ago)
Document Number: L13000163436
FEI/EIN Number 46-4163847
Address: 10261 CODY LN, ORLANDO, FL 32825
Mail Address: 10261 CODY LN, ORLANDO, FL 32825
ZIP code: 32825
County: Orange
Place of Formation: FLORIDA

Agent

Name Role Address
ADELMY, TEJADA A Agent 10261 CODY LN, ORLANDO, FL 32825

Managing Member

Name Role Address
ADELMY, TEJADA A Managing Member 10261 CODY LN, ORLANDO, FL 32825

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2022-02-09 ADELMY, TEJADA A No data
CHANGE OF PRINCIPAL ADDRESS 2017-02-28 10261 CODY LN, ORLANDO, FL 32825 No data
CHANGE OF MAILING ADDRESS 2017-02-28 10261 CODY LN, ORLANDO, FL 32825 No data
REGISTERED AGENT ADDRESS CHANGED 2017-02-28 10261 CODY LN, ORLANDO, FL 32825 No data

Documents

Name Date
ANNUAL REPORT 2024-04-08
ANNUAL REPORT 2023-04-19
ANNUAL REPORT 2022-02-09
ANNUAL REPORT 2021-03-02
ANNUAL REPORT 2020-03-26
ANNUAL REPORT 2019-03-28
ANNUAL REPORT 2018-02-07
ANNUAL REPORT 2017-02-28
ANNUAL REPORT 2016-03-10
ANNUAL REPORT 2015-03-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343722898 0418800 2019-01-17 5785 SE PINEHURST TRAIL, HOBE SOUND, FL, 33455
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-01-17
Emphasis P: FALL, L: FALL
Case Closed 2020-04-28

Related Activity

Type Inspection
Activity Nr 1372366
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2019-04-05
Abatement Due Date 2019-04-24
Current Penalty 2122.0
Initial Penalty 3031.0
Final Order 2019-04-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about January 17, 2019, at the edge of a roof on the west exterior elevation of a building located at 5785 SE Pinehurst Trail in Hobe Sound, Florida, employees were exposed to a fall of approximately 14 feet when applying grout between masonry wall capstones at the unprotected edge of a walking/working surface prior to being provided with a training program that would enable them to recognize the hazards associated with falls.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B01
Issuance Date 2019-04-05
Abatement Due Date 2019-04-24
Current Penalty 4250.0
Initial Penalty 6062.0
Final Order 2019-04-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about January 17, 2019, at the edge of a roof on the west exterior elevation of a building located at 5785 SE Pinehurst Trail in Hobe Sound, Florida, employees were exposed to a fall of approximately 14 feet when applying grout between masonry wall capstones at the unprotected edge of a walking/working surface while not being protected from falling to the lower level. T. Escobar Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(15), which was contained in OSHA inspection number 1159305, citation number 1, item number 2 and was affirmed as a final order on 08/18/2016, with respect to a workplace located at 297 Sparrow Hawk Drive in Groveland, Florida 34736.
341593051 0420600 2016-06-30 297 SPARROW HAWK DR, GROVELAND, FL, 34736
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-06-30
Emphasis L: FALL, P: FALL
Case Closed 2016-08-25

Related Activity

Type Inspection
Activity Nr 1159293
Safety Yes
Type Inspection
Activity Nr 1159298
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2016-07-21
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a. At the site, frequent inspections were not conducted to assure that stucco work around a window on a two story building was conducted safely with the use of fall protection equipment, on or about 06/30/2016.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B15
Issuance Date 2016-07-21
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: a. At the site, an employee was exposed to a 9 foot fall hazard, in that, no fall protection was implemented while on the roof of a two story building during stucco repair work around a window, on or about 06/30/2016.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2016-07-21
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. At the site, employees were exposed to a fall hazard, in that, a ladder used to gain access to the roof of the building extended 20 inches above the landing surface, on or about 06/30/2016.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2016-07-21
Abatement Due Date 2016-09-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for employees using ladders and stairways, that enabled each employee to recognize hazards related to ladders and stairways, and the procedures to be followed to minimize these hazards: a. At the site, employees used ladders to access the roof where stucco was conducted around a window on the second floor, without being provided ladder training to include at a minimum the following: 1. The nature of fall hazards in the work area. 2. The correct procedures for erecting, maintaining and disassembling the fall protection systems to be used. 3. The proper construction, use, placement, and care of handling of all stairways and ladders. 4. The maximum intended load-carrying capacities of ladders used and. 5. The OSHA standards on ladders and stairways.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2016-07-21
Abatement Due Date 2016-09-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) a. At the site, employees were exposed to masonry cement containing silicates used for stucco work, in that, a written hazard communication program was not developed, maintained and implemented at the workplace, on or about 06/30/2016.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2016-07-21
Abatement Due Date 2016-09-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical: (Construction Reference: 1926.59) a. At the site, employees were exposed to masonry cement containing silicates used for stucco work, in that, safety data sheets were not maintained at the workplace, on or about 06/30/2016.
Citation ID 02003
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2016-07-21
Abatement Due Date 2016-09-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a. At the site, employees were exposed to masonry cement containing silicates used for stucco work, in that, employees were not provided training and education on the hazardous chemicals at the workplace, on or about 06/30/2016.
Citation ID 02004
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2016-07-21
Abatement Due Date 2016-09-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-18
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer/employee responsibilities, on or about 06/30/2016.

Date of last update: 21 Feb 2025

Sources: Florida Department of State