Entity Name: | ATLANTIC RENOVATION & CONTRACTING SERVICES LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
ATLANTIC RENOVATION & CONTRACTING SERVICES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 12 Nov 2013 (11 years ago) |
Document Number: | L13000158445 |
FEI/EIN Number |
46-4108258
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 156 N. FLORIDA AVE., INVERNESS, FL, 34453, US |
Mail Address: | 156 N. FLORIDA AVE., INVERNESS, FL, 34453, US |
ZIP code: | 34453 |
County: | Citrus |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
HUBBARD MICHAEL R | Managing Member | 156 N. FLORIDA AVE., INVERNESS, FL, 34453 |
UNITED STATES CORPORATION AGENTS, INC. | Agent | - |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G13000124662 | ATLANTIC RENOVATION & CONTRACTING SERVICES LLC | ACTIVE | 2013-12-19 | 2028-12-31 | - | 156 N. FLORIDA AVE, INVERNESS, FL, 34453 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT ADDRESS CHANGED | 2023-02-02 | 476 RIVERSIDE AVE., JACKSONVILLE, FL 32202 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-07 |
ANNUAL REPORT | 2023-02-01 |
ANNUAL REPORT | 2022-01-26 |
ANNUAL REPORT | 2021-02-19 |
ANNUAL REPORT | 2020-01-13 |
ANNUAL REPORT | 2019-04-01 |
ANNUAL REPORT | 2018-04-26 |
ANNUAL REPORT | 2017-01-09 |
ANNUAL REPORT | 2016-03-25 |
ANNUAL REPORT | 2015-01-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342656246 | 0419700 | 2017-09-22 | 4553 SW 65TH PLACE, OCALA, FL, 34474 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1266092 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2017-09-29 |
Current Penalty | 1303.8 |
Initial Penalty | 2173.0 |
Final Order | 2017-10-24 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a. On or about September 22, 2017 one employee was observed using a pneumatic nail gun to secure plywood sheathing to the roof trusses without wearing any eye protection. The same employee was observed using a DeWalt brand circular saw to cut the plywood to size without wearing any eye protection. The employee was exposed to impact eye injuries from debris and saw dust because he was not protected by appropriate eye or face protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-09-29 |
Current Penalty | 1738.2 |
Initial Penalty | 2897.0 |
Final Order | 2017-10-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about September 22, 2017 one employee was observed working on the roof of a single story residential dwelling with a 5:12 pitch, steep slope roof installing roof sheathing and truss blocking and was not protected from falling by any means of personal fall protection, guardrails, or safety nets, exposing him to a fall of more than 9 feet to the ground below. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2017-09-29 |
Current Penalty | 1303.8 |
Initial Penalty | 2173.0 |
Final Order | 2017-10-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about September 22, 2017 the employees were using an 8 foot Werner brand fiberglass step ladder, in the closed position, leaning against the exterior concrete wall to gain access to the roof trusses to climb up and access the roof. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2017-09-29 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-10-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a. On or about September 22, 2017 one employee had used an 8 foot Werner brand stepladder, to gain access to the roof surface, 10 feet above the ground. The employee used the top step as a step in order to climb up onto and through the roof trusses. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7788617802 | 2020-06-04 | 0491 | PPP | 156 N. Florida Ave., INVERNESS, FL, 34453-1607 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
6123648906 | 2021-05-01 | 0491 | PPS | 156 N Florida Ave, Inverness, FL, 34453-1607 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 02 Apr 2025
Sources: Florida Department of State