Entity Name: | ALTERNATIVE CONSTRUCTION LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
ALTERNATIVE CONSTRUCTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 18 Sep 2013 (12 years ago) |
Date of dissolution: | 26 Sep 2014 (11 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 26 Sep 2014 (11 years ago) |
Document Number: | L13000132328 |
Address: | 4926 YORK ST., UNIT A, CAPE CORAL, FL, 33904, US |
Mail Address: | 4926 YORK ST., UNIT A, CAPE CORAL, FL, 33904, US |
ZIP code: | 33904 |
County: | Lee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
LEMON TRAVIS C | Agent | 4926 YORK ST., CAPE CORAL, FL, 33904 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2014-09-26 | - | - |
Name | Date |
---|---|
Florida Limited Liability | 2013-09-18 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346327117 | 0420600 | 2022-11-04 | 14011 US HIGHWAY 301 S, RIVERVIEW, FL, 33578 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1632710 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1632712 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2022-12-14 |
Current Penalty | 4144.0 |
Initial Penalty | 4144.0 |
Final Order | 2023-01-31 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For the construction site at 14011 US Highway 301 S, Riverview, FL 33578, as observed on or about 11/04/2022, the employer exposed employees to fall hazards of approximately 42 feet while they were conducting roofing work on an 81 ft. wide flat roof, in that, conventional fall protection was not being used, and a safety warning line was not in place when a safety monitoring system was being used. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260502 F01 |
Issuance Date | 2022-12-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-01-31 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: a) For the construction site at 14011 US Highway 301 S, Riverview, FL 33578, as observed on or about 11/04/2022, the employer exposed employees to fall hazards of approximately 42 feet while they were conducting roofing work on an 81 ft. wide flat roof, in that, conventional fall protection was not being used, and a safety warning line was not in place when a safety monitoring system was being used. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2022-12-14 |
Current Penalty | 4144.0 |
Initial Penalty | 4144.0 |
Final Order | 2023-01-31 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) For the construction site at 14011 US Highway 301 S, Riverview, FL 33578, as observed on or about 11/04/2022, the employer exposed employees to fall hazards of approximately 10 feet while they were using a job made ladder that did not extend above the upper surface/roof hatch being accessed. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State