Search icon

LION CONSTRUCTION JAX LLC - Florida Company Profile

Company Details

Entity Name: LION CONSTRUCTION JAX LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

LION CONSTRUCTION JAX LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 04 Sep 2013 (12 years ago)
Date of dissolution: 25 Sep 2015 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (9 years ago)
Document Number: L13000125006
FEI/EIN Number 46-3566967

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6653 POWERS AVE, JACKSONVILLE, FL, 32217, US
Mail Address: 6653 POWERS AVE, JACKSONVILLE, FL, 32217, US
ZIP code: 32217
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ESTRADA SANCHEZ NAPOLEON Managing Member 10960 BEACH BLVD STE 11, JACKSONVILLE, FL, 32246
TAXSMART ACCOUNTING SERVICES LLC Agent -

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -
CHANGE OF PRINCIPAL ADDRESS 2014-07-03 6653 POWERS AVE, STE 241, JACKSONVILLE, FL 32217 -
CHANGE OF MAILING ADDRESS 2014-07-03 6653 POWERS AVE, STE 241, JACKSONVILLE, FL 32217 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J15000785903 ACTIVE 1000000687397 DUVAL 2015-07-15 2025-07-22 $ 1,171.02 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825

Documents

Name Date
ANNUAL REPORT 2014-07-03
Florida Limited Liability 2013-09-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339823486 0419700 2014-06-25 14950 VENOSA CIR., JACKSONVILLE, FL, 32258
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-06-25
Emphasis L: FALL, P: FALL
Case Closed 2018-09-19

Related Activity

Type Inspection
Activity Nr 982360
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 A02 II J
Issuance Date 2014-08-13
Current Penalty 3500.0
Initial Penalty 3500.0
Final Order 2014-09-17
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not of the three-wire type: a. On or about June 25, 2014, at the temporary power service post, the extension cord used to power the microwave oven did not have a grounding prong, exposing employees to a 115-Volt, 8-Amp shock hazard from the ungrounded microwave oven.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-08-13
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2014-09-17
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Employees engaged in residential construction activities 6 feet (1.8m) or more above the lower levels were not protected by guardrail systems, safety net systems, or personal fall arrest systems: a. On or about June 25, 2014, at the top of the stairs in the left duplex unit, employees who accessed the second-floor were exposed to and 11 feet fall hazard in that a guardrail system was not installed on the stairs. b. On or about June 25, 2014, in the roof trusses of the second-story of the left duplex unit, an employee installing bracing was exposed to a 9 feet fall hazard to the floor in that he was not protected by a fall protection system.