347122988
|
0420600
|
2023-11-21
|
3761 NORTHEAST 36TH AVENUE, OCALA, FL, 34479
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-11-21
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2024-01-29
|
Related Activity
Type |
Referral |
Activity Nr |
2101942 |
Safety |
Yes |
|
|
346701626
|
0420600
|
2023-05-15
|
3761 NORTHEAST 36TH AVENUE, OCALA, FL, 34479
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-05-15
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-11-16
|
Related Activity
Type |
Referral |
Activity Nr |
2028318 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-10-02 |
Abatement Due Date |
2023-10-27 |
Current Penalty |
15625.0 |
Initial Penalty |
30938.0 |
Final Order |
2023-10-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. At the Viking Production area, located at 3761 Northeast 36th Avenue, Ocala, FL: On or about May 15, 2023, the employer exposed employees to caught in hazards, in that, reciprocating motion by the nailing gantry component of the Viking pallet assembly machine, model M-304A, Serial # 558C, was not guarded. Phoenix Wood Products, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1623385, citation number 01, item number 001 and was affirmed as a final order on 04/04/2023, with respect to a workplace located at 3761 NE 36th Ave, Ocala, FL 34479. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 II |
Issuance Date |
2023-10-02 |
Abatement Due Date |
2023-10-27 |
Current Penalty |
0.0 |
Initial Penalty |
77344.0 |
Final Order |
2023-10-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(ii):The employer did not certify that periodic inspections of the energy control procedures had been performed: a. For the Viking Production area, located at 3761 Northeast 36th Avenue, Ocala, FL: On or about May 15, 2023, the employer exposed employees to struck by hazards, in that the employer did not certify that periodic inspection of the energy control procedures for the Viking pallet assembly machine, model M-304A, Serial # 558C was performed. Phoenix Wood Products, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1461586, citation number 01, item number 001 and was affirmed as a final order on 06/10/2020, with respect to a workplace located at 3761 NE 36th Ave, Ocala, FL 34479. Phoenix Wood Products, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1623385, citation number 01, item number 001 and was affirmed as a final order on 04/04/2023, with respect to a workplace located at 3761 NE 36th Ave, Ocala, FL 34479. |
|
|
346233851
|
0420600
|
2022-09-20
|
3911 NE 36TH AVE., OCALA, FL, 34479
|
|
Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-09-20
|
Case Closed |
2023-08-30
|
Related Activity
Type |
Accident |
Activity Nr |
1948677 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II B |
Issuance Date |
2023-03-17 |
Abatement Due Date |
2023-04-12 |
Current Penalty |
15625.0 |
Initial Penalty |
15625.0 |
Final Order |
2023-03-30 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) For the Rayco production area, on or about September 19, 2022, and at times prior to, employees were exposed to caught-in hazards, in that, the employer did not have energy control procedures for jam clearing and relied on cycle pause buttons and emergency stop buttons to de-energize the nailing gantry component of the Rayco pallet assembly machine, model Pallet Pro, Serial # P201849. b) For the Rayco production area, on or about September 19, 2022, and at times prior to, employees were exposed to caught-in hazards, in that, the employer did not have energy control procedures for jam clearing and relied on cycle pause buttons and emergency stop buttons to de-energize the nailing gantry component of the Rayco pallet assembly machine, model Pallet Pro, Serial # P201957-0PP. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 D03 |
Issuance Date |
2023-03-17 |
Abatement Due Date |
2023-04-12 |
Current Penalty |
15469.0 |
Initial Penalty |
15469.0 |
Final Order |
2023-03-30 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(3):All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) For the Rayco production area, on or about September 19, 2022, and at times prior to, the employer exposed employees to caught-in hazards, in that, cycle pause buttons and emergency stop buttons and devices were used to de-energize the nailing gantry component of the Rayco pallet assembly machine, model Pallet Pro, Serial # P201849, for pallet jam clearing. b) For the Rayco production area, on or about September 19, 2022 and at times prior to, the employer exposed employees to caught-in hazards, in that, cycle pause buttons and emergency stop buttons and devices were used to de-energize the nailing gantry component of the Rayco pallet assembly machine, model Pallet Pro, Serial # Serial # P201957-0PP, for pallet jam clearing. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-03-17 |
Abatement Due Date |
2023-04-12 |
Current Penalty |
15469.0 |
Initial Penalty |
15469.0 |
Final Order |
2023-03-30 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) For the Rayco production area, on or about September 19, 2022, and at times prior to, the employer exposed employees to caught-in hazards, in that, reciprocating motion by the nailing gantry component of the Rayco pallet assembly machine, model Pallet Pro, Serial # P201849, was not guarded. b) For the Rayco production area, on or about September 19, 2022, and at times prior to, the employer exposed employees to caught-in hazards, in that, reciprocating motion by the nailing gantry component of the Rayco pallet assembly machine, model Pallet Pro, Serial # P201957-0PP, was not guarded. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100147 C06 II |
Issuance Date |
2023-03-17 |
Abatement Due Date |
2023-04-12 |
Current Penalty |
22101.0 |
Initial Penalty |
22101.0 |
Final Order |
2023-03-30 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(ii):The employer did not certify that periodic inspections of the energy control procedures had been performed: a) For the Rayco Production area, on or about September 19, 2022 and at times prior to, the employer did not certify that periodic inspection of the energy control procedures for the Rayco pallet assembly machine, model Pallet Pro, Serial # P201849 was performed. b) For the Rayco Production area, on or about September 19, 2022 and at times prior to, the employer did not certify that periodic inspection of the energy control procedures for the Rayco pallet assembly machine, model Pallet Pro, Serial # P201957-0PP was performed. Phoenix Wood Products LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1461586, citation number 01, item number 001 and was affirmed as a final order on 06/10/2020, with respect to a workplace located at 3761 NE 36th Ave, Ocala, FL 34479. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19040039 A01 |
Issuance Date |
2023-03-17 |
Current Penalty |
0.0 |
Initial Penalty |
11050.0 |
Final Order |
2023-03-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(1):The employer did not report within 8-hours the death of an employee resulting from a work-related incident a) On or about September 19, 2022, the employer did not report a work-related death to OSHA within 8-hours. |
|
|
344615869
|
0419700
|
2020-02-07
|
3761 NE 36TH AVE, OCALA, FL, 34479
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-02-27
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2020-08-17
|
Related Activity
Type |
Referral |
Activity Nr |
1540979 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2020-05-01 |
Current Penalty |
5205.0 |
Initial Penalty |
8675.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about February 7, 2020, the energy control procedures for the Baker Double Notcher was not reviewed annually. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2020-05-01 |
Current Penalty |
7287.0 |
Initial Penalty |
12145.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a. On or about February 7, 2020, at the Baker Double Notcher, an employee trained as an affected employee was working as an authorized employee, but was not provided authorized employee training, exposing the employee to an amputation hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 D05 I |
Issuance Date |
2020-05-01 |
Current Penalty |
7285.0 |
Initial Penalty |
12145.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a. On or about February 7, 2020, the energy control procedures for the Baker Double Notcher did not account for the kinetic energy stored in the machine, exposing an employee to an amputation hazard. |
|
|
342767589
|
0419700
|
2017-11-13
|
3761 NE 36TH AVE, OCALA, FL, 34479
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-11-13
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2018-10-25
|
Related Activity
Type |
Complaint |
Activity Nr |
1281920 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100213 R03 |
Issuance Date |
2017-12-08 |
Current Penalty |
4436.5 |
Initial Penalty |
8873.0 |
Final Order |
2017-12-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(r)(3): For combination or universal woodworking machines each point of operation of any tool shall be guarded as required for such a tool in a separate machine. a. On or about November 13, 2017 the owner did not assure the throat opening of the Whirlwind 212R 18" Upcut saw was guarded to prevent the operators hand from passing across the blade opening in the table. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2017-12-08 |
Abatement Due Date |
2018-01-29 |
Current Penalty |
1616.0 |
Initial Penalty |
3232.0 |
Final Order |
2017-12-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a. On or about November 13, 2017, in the Reman section of the facility the employer did not assure the horizontal shafts of the chain drive exit conveyor belt system positioned 32" above the floor was completely enclosed by a casing, protecting employees from caught in hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100110 D10 |
Issuance Date |
2017-12-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-29 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.110(d)(10): Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic: a. On or about November 13, 2017 the employer did not assure the LP gas tanks in storage for the forklift use was protected from vehicular traffic by barricades or bollards installed around the container racks. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 B07 IV |
Issuance Date |
2017-12-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(iv): There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. a). On or about November 13, 2017 the employer did not assure the 100 Amp Square D, Single Throw Safety switch box located at the Reman chain conveyor belt table had all non used openings effectively closed. |
|
|