Entity Name: | ESCALANTE CONSTRUCTION LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
ESCALANTE CONSTRUCTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 06 Aug 2013 (12 years ago) |
Last Event: | LC AMENDMENT |
Event Date Filed: | 02 Dec 2016 (8 years ago) |
Document Number: | L13000110516 |
FEI/EIN Number |
46-3367011
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 180 CALDWELL ST., APOPKA, FL, 32712, US |
Mail Address: | 180 CALDWELL ST., APOPKA, FL, 32712, US |
ZIP code: | 32712 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ESCALANTE HUGO R | Managing Member | 180 CALDWELL ST., APOPKA, FL, 32712 |
OJEDA ARVELO KRISTY D | Vice President | 180 CALDWELL ST., APOPKA, FL, 32712 |
ESCALANTE HUGO R | Agent | 180 CALDWELL ST., APOPKA, FL, 32712 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2022-04-05 | 180 CALDWELL ST., APOPKA, FL 32712 | - |
CHANGE OF MAILING ADDRESS | 2022-04-05 | 180 CALDWELL ST., APOPKA, FL 32712 | - |
REGISTERED AGENT ADDRESS CHANGED | 2022-04-05 | 180 CALDWELL ST., APOPKA, FL 32712 | - |
LC AMENDMENT | 2016-12-02 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-21 |
ANNUAL REPORT | 2024-04-18 |
ANNUAL REPORT | 2023-04-21 |
ANNUAL REPORT | 2022-04-05 |
ANNUAL REPORT | 2021-01-09 |
ANNUAL REPORT | 2020-05-25 |
AMENDED ANNUAL REPORT | 2019-08-21 |
ANNUAL REPORT | 2019-04-26 |
ANNUAL REPORT | 2018-05-01 |
ANNUAL REPORT | 2017-04-29 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346509029 | 0419730 | 2023-02-16 | 1320 W OAK RIDGE RD, ORLANDO, FL, 32809 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2000538 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2023-08-04 |
Current Penalty | 2009.4 |
Initial Penalty | 3349.0 |
Final Order | 2023-08-21 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. a) At 1320 West Oak Ridge Rd, Orlando FL 32809: On or about February 16, 2023, employees were exposed to fall hazards of approximately 15-feet to the lower level while performing roofing work on a commercial building with a 3:12 pitch roof without fall protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2023-08-04 |
Abatement Due Date | 2023-08-23 |
Current Penalty | 2009.4 |
Initial Penalty | 3349.0 |
Final Order | 2023-08-21 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Jobsite: At 1320 West Oak Ridge Rd, Orlando FL 32809: On or about February 16, 2023, the Gorilla extension ladder being used to access the roof was extended approximately 1 foot over the roof landing, exposing employees to fall hazards of approximately 8 feet. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-03-28 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2017-07-20 |
Related Activity
Type | Inspection |
Activity Nr | 1220881 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-05-24 |
Current Penalty | 1955.4 |
Initial Penalty | 3259.0 |
Final Order | 2017-06-12 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about March 28, 2017 two employees were stripping old roof materials from a one story 5;12 pitch steep slope roof surface and were not protected by any means of personal fall protection, guardrails, or safety nets, exposing them to falls in excess of 8 feet o the ground below. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 2017-05-24 |
Abatement Due Date | 2017-07-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-06-12 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): A Safety and Health Program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard: a. On or about March 28, 2017, at the worksite, a safety and health program had not been intiated and maintained which addressed the following basic elements; 1. Management Commitment and Leadership A. Policy statement: goals established, issued, and communicated to employees. B. Program Reviewed Annually. C. Participation in safety meetings, inspections; agenda item in meetings. D. Adequate commitment of resources. E. Safety rules and procedures incorporated into site operations. F. Management observations of safety rules. 2. Assignment of Responsibility A. Safety designee on site, knowledgeable, and accountable. B. Supervisors' (including foremen) safety and health responsibilities understood. C. Employees adherence to safety rules. 3. Identification and Control of Hazards A. Periodic site inspection program involving supervisors. B. Preventive controls in place (PPE, Maintenance, Engineering Controls). C. Action taken to address hazards. D. Safety Committee, where appropriate. E. Technical reference materials available. 4. Training and Education A. Supervisors receive basic safety and health training. B. Specialized training taken when needed. C. Existence of an employee training program, which is ongoing and effective. 5. Recordkeeping and Hazard Analysis A. Records maintained of employee illnesses/injuries, and posted. B. Supervisors perform incident investigations, determine causes, propose corrective action. C. Injuries, near misses, and illnesses are evaluated for trends, similar causes; corrective action initiated. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State