Search icon

STRONG CONSTRUCTION LLC. - Florida Company Profile

Company Details

Entity Name: STRONG CONSTRUCTION LLC.
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

STRONG CONSTRUCTION LLC. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 10 Jun 2013 (12 years ago)
Last Event: LC AMENDMENT
Event Date Filed: 06 Sep 2016 (9 years ago)
Document Number: L13000083871
FEI/EIN Number 46-2669270

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: HEIMAN AVE, 1656, FORT MYERS, FL, 33905, US
Mail Address: HEIMAN AVE, 1656, FORT MYERS, FL, 33905, US
ZIP code: 33905
County: Lee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CARDENAS FRANCISCO J Managing Member 1656 HEIMAN AVE, FORT MYERS, FL, 33905
CARDENAS FRANCISCO J Agent HEIMAN AVE, FORT MYERS, FL, 33905

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2024-05-14 CARDENAS, FRANCISCO J -
LC AMENDMENT 2016-09-06 - -

Documents

Name Date
ANNUAL REPORT 2025-01-16
AMENDED ANNUAL REPORT 2024-05-14
ANNUAL REPORT 2024-01-03
ANNUAL REPORT 2023-02-15
ANNUAL REPORT 2022-03-04
ANNUAL REPORT 2021-01-12
ANNUAL REPORT 2020-01-20
ANNUAL REPORT 2019-02-13
ANNUAL REPORT 2018-03-05
ANNUAL REPORT 2017-03-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343418349 0418800 2018-08-20 6965 AVALON CIRCLE, NAPLES, FL, 34112
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-08-20
Emphasis L: FALL, P: FALL
Case Closed 2018-11-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2018-10-03
Current Penalty 3104.4
Initial Penalty 5174.0
Final Order 2018-10-29
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about August 20th, 2018, at 6965 Avalon Circle Naples FL, 34112, employees were exposed to 12 feet fall hazards while in the process of performing shell work on a new residential structure. b. On or about August 20th, 2018, at 6965 Avalon Circle Naples FL, 34112, an employee was exposed to 17 feet fall hazards while in the process of performing shell work on a new residential structure.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2018-10-03
Abatement Due Date 2018-10-30
Current Penalty 3104.4
Initial Penalty 5174.0
Final Order 2018-10-29
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about August 20th, 2018, at 6965 Avalon Circle Naples FL, 34112, employees were not knowledgeable in recognizing fall hazards while in the process of performing shell work on a residential structure at a height of approximate 12-17 feet.

Date of last update: 01 Apr 2025