Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-05-14
|
Case Closed |
2020-08-25
|
Related Activity
Type |
Referral |
Activity Nr |
1453096 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1398771 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2019-09-09 |
Abatement Due Date |
2019-11-25 |
Current Penalty |
1515.5 |
Initial Penalty |
3031.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) At the boat production facility, for employees applying chemical products and paints, such as but not limited to industrial grade acetone, and polyester gel coat. Employees were allowed to use 3M, tight fit half face, Cartridge Respirators, 6200, on or about June 20, 2019. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 II |
Issuance Date |
2019-09-09 |
Abatement Due Date |
2019-10-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1)(ii): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) At the boat manufacturing facility, for employees applying chemical products, such as but not limited to, industrial grade acetone, and polyester gel coat. Employees were allowed to use 3M , tight fit, half face, Cartridge Respirators, 6200, on or about June 20, 2019. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2019-09-09 |
Abatement Due Date |
2019-10-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) At the boat production facility, for employees applying chemical products and paints such as but not limited to industrial grade acetone, polyester gel coat , employees were using the half face, 3M, Cartridge Respirators, 6200 without being fit tested prior to use, on or about June 20, 2019. |
|
Citation ID |
02001A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2019-09-09 |
Abatement Due Date |
2019-10-03 |
Current Penalty |
1515.5 |
Initial Penalty |
3031.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59) (a) At the boat manufacturing facility, employees used chemicals, such as but not limited to, acetone, titanium dioxide, and polyester resin, on or about June 20, 2019. |
|
Citation ID |
02001B |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2019-09-09 |
Abatement Due Date |
2019-10-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) At the boat manufacturing facility, employees used chemicals, such as but not limited to, acetone, titanium dioxide, and polyester resin, on or about June 20, 2019. |
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-07-12
|
Case Closed |
2020-08-25
|
Related Activity
Type |
Referral |
Activity Nr |
1451755 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1404161 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100106 D04 I |
Issuance Date |
2019-09-09 |
Abatement Due Date |
2020-02-25 |
Current Penalty |
2652.0 |
Initial Penalty |
5304.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(d)(4)(i): Openings to other rooms or buildings was not provided with approved self-closing fire doors. a. At the boat manufacturing building, employees were exposed to fire and smoke inhalation hazards, in that, the flammable liquid storage room was not equipped with approved self-closing fire doors, on or about May 7, 2019. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100106 E02 IV C |
Issuance Date |
2019-09-09 |
Current Penalty |
2652.0 |
Initial Penalty |
5304.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(2)(iv)(c): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were used where there were open flames or other sources of ignition within the possible path of vapor travel. a. At the assembly building, employees were exposed to fire and smoke inhalation hazards, in that, flammables liquids, such as but not limited to, acetone were used near open flames, on or about April 19, 2019, |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100106 H08 III |
Issuance Date |
2019-09-09 |
Abatement Due Date |
2019-10-25 |
Current Penalty |
2652.0 |
Initial Penalty |
5304.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(h)(8)(iii): Combustible waste and residues including rags used for wiping combustible and/or flammable liquids were not stored in closed metal waste cans. a. At the boat assembly building, employees were exposed to fire and smoke inhalation, in that, rags that had been previously soaked with flammable chemicals, such as but not limited to, acetone, isopropyl alcohol and mineral spirits were placed in a netted blue bag and disposed once a week, on or about May 7, 2019. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100157 G01 |
Issuance Date |
2019-09-09 |
Current Penalty |
2652.0 |
Initial Penalty |
5304.0 |
Final Order |
2019-09-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a. At the establishment, employees were allowed to use fire extinguishers were exposed to burns and smoke inhalation, on or about May 7, 2019. |
|
|