Search icon

ORQUICELY CONSTRUCTION, LLC - Florida Company Profile

Company Details

Entity Name: ORQUICELY CONSTRUCTION, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

ORQUICELY CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 29 Apr 2013 (12 years ago)
Date of dissolution: 25 May 2016 (9 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 25 May 2016 (9 years ago)
Document Number: L13000064690
FEI/EIN Number 46-2594919

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4046 N. GOLDENROD RD., #272, WINTER PARK, FL, 32792
Mail Address: 4046 N. GOLDENROD RD., #272, WINTER PARK, FL, 32792
ZIP code: 32792
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
QUEZADA ORQUIDEA Manager 4046 N. GOLDENROD RD., #272, WINTER PARK, FL, 32792
QUEZADA ORQUIDEA Agent 4046 N. GOLDENROD RD., #272, WINTER PARK, FL, 32792

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2016-05-25 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2016-05-25
ANNUAL REPORT 2015-03-19
ANNUAL REPORT 2014-04-17
Florida Limited Liability 2013-04-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341036796 0419700 2015-11-04 77 SPANISH BAY DR, SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-11-05
Emphasis L: FALL, P: FALL
Case Closed 2017-10-30

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2016-01-21
Abatement Due Date 2016-02-09
Current Penalty 2640.0
Initial Penalty 2640.0
Contest Date 2016-02-17
Final Order 2016-07-25
Nr Instances 5
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a. On or about November 4, 2015, on the second level of the scaffolds at the front side of the house, employees applying stucco cement were exposed to a 13 feet fall hazard in that the scaffolds were not fully planked. b. On or about November 4, 2015, on the second level of the scaffold at the southwest corner of the house, employees applying stucco cement were exposed to a 13 feet fall hazard in that the scaffolds were not fully planked. c. On or about November 4, 2015, on the second level of the scaffold at the north side of the house, employees applying stucco cement were exposed to a 13 feet fall hazard in that the scaffolds were not fully planked.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-01-21
Abatement Due Date 2016-02-09
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-02-17
Final Order 2016-07-25
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Endframes were used as a means of access: a. On or about November 4, 2015, along the south side of the garage, a means of access was not installed for employees who accessed the second level of the scaffold by climbing the endframes, exposing themselves to a 13 feet fall hazard.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-01-21
Abatement Due Date 2016-02-09
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-02-17
Final Order 2016-07-25
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. On or about November 4, 2015, on the second levels of the three scaffolds erected on the east side of the house, employees were exposed to 13 feet fall hazards in that the scaffolds were missing top rails, mid rails, and end rails. b. On or about November 4, 2015, on the second level of the scaffold erected on the southwest corner of the house, employees applying stucco were exposed to a 13 feet fall hazard in that the scaffold was missing an end rail.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2016-01-21
Abatement Due Date 2016-02-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-02-17
Final Order 2016-07-25
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work: a. On or about November 4, 2015, on the job site, plastering employees involved in erecting, moving, operating, repairing, maintaining, and inspecting scaffold systems were not trained to recognize hazards of incomplete guardrails, planking, and ladder access.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2016-01-21
Abatement Due Date 2016-02-02
Current Penalty 3080.0
Initial Penalty 3080.0
Contest Date 2016-02-17
Final Order 2016-07-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a. On or about November 4, 2015, on the 6:12 pitch roof over the garage, a ladder or stairway was not provided to access the second-story roof. An employee was exposed to a 10 feet fall hazard while using an A-frame scaffold frame to climb to the second story roof.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2016-01-21
Abatement Due Date 2016-02-09
Current Penalty 10780.0
Initial Penalty 10780.0
Contest Date 2016-02-17
Final Order 2016-07-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. Employees installing stucco at elevations of six feet or more above the ground are not being protected from fall hazards by a fall protection system. The employer fails to assure effective protection against falls as required by the standard, as demonstrated on November 4, 2015, on the 6:12 pitch roof over the garage, an employee placing a protective tarp was exposed to a 10 feet fall hazard from the eave, and on the 6:12 second story roof above the front entrance, an employee placing a protective tarp was exposed to a 20 feet fall hazard from the eave in that they were not protected by any fall protection systems. Orquicely Construction, LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1042322, citation number 01, item number 001 and was affirmed as a final order on May 12, 2015, with respect to a workplace located at 23 Forest Edge Dr, Saint Johns, Florida.
340423227 0419700 2015-02-20 23 FOREST EDGE DR, SAINT JOHNS, FL, 32259
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2015-02-21
Emphasis P: FALL, L: FALL
Case Closed 2015-05-22

Related Activity

Type Inspection
Activity Nr 1042467
Safety Yes
Type Referral
Activity Nr 964811
Safety Yes
Type Inspection
Activity Nr 1042466
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-04-28
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-05-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about February 20, 2015, at the east side of the building, employees doing sheathing work on a 6:12 pitch roof were not protected from a 22 feet fall hazard by the use of a fall protection system.