Entity Name: | YARIS CONSTRUCTION, LLC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
YARIS CONSTRUCTION, LLC. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 20 Mar 2013 (12 years ago) |
Document Number: | L13000042188 |
FEI/EIN Number |
46-2421100
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5832 CREEK STATION DR, PENSACOLA, FL, 32504, US |
Mail Address: | 5832 CREEK STATION DR, PENSACOLA, FL, 32504, US |
ZIP code: | 32504 |
County: | Escambia |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ALVARADO AYARIS | Managing Member | 5832 CREEK STATION DR, PENSACOLA, FL, 32504 |
ALVARADO AYARIS | Agent | 5832 CREEK STATION DR, PENSACOLA, FL, 32504 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2021-01-19 | 5832 CREEK STATION DR, PENSACOLA, FL 32504 | - |
CHANGE OF MAILING ADDRESS | 2021-01-19 | 5832 CREEK STATION DR, PENSACOLA, FL 32504 | - |
REGISTERED AGENT ADDRESS CHANGED | 2021-01-19 | 5832 CREEK STATION DR, PENSACOLA, FL 32504 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-02 |
ANNUAL REPORT | 2023-02-09 |
ANNUAL REPORT | 2022-03-14 |
ANNUAL REPORT | 2021-01-19 |
ANNUAL REPORT | 2020-06-05 |
ANNUAL REPORT | 2019-03-13 |
ANNUAL REPORT | 2018-03-27 |
ANNUAL REPORT | 2017-04-06 |
ANNUAL REPORT | 2016-02-02 |
ANNUAL REPORT | 2015-04-28 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345352207 | 0418600 | 2021-06-09 | 2636 PLEASANT VALLEY DR., CANTONMENT, FL, 32533 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2021-07-15 |
Abatement Due Date | 2021-07-27 |
Current Penalty | 3511.0 |
Initial Penalty | 3511.0 |
Final Order | 2021-08-10 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 2636 Pleasant Valley Drive, Cantonment, Florida: On or about June 9, 2021 and at times prior; the employer allowed her employees to perform roofing activities without fall protection exposing her employees to a fall hazard of up to 12 feet 10 inches to the ground below. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2021-07-15 |
Abatement Due Date | 2021-07-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-08-10 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) At 2636 Pleasant Valley Drive, Cantonment, Florida: On or about June 9, 2021 and at times prior; the employer allowed her employees to perform roofing activities without first ensuring her employees were trained on the hazards associated with falls to include but not limited to setting up and inspecting fall protection exposing her employees to a fall hazard of up to 12 feet 10 inches to the ground below. |