Search icon

3 D SOLAR LLC - Florida Company Profile

Company Details

Entity Name: 3 D SOLAR LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

3 D SOLAR LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 17 Jan 2013 (12 years ago)
Date of dissolution: 24 Sep 2021 (4 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 24 Sep 2021 (4 years ago)
Document Number: L13000009620
FEI/EIN Number 461874239

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 13266 BYRD DR, ODESSA, FL, 33556, US
Mail Address: 13266 BYRD DR, ODESSA, FL, 33556, US
ZIP code: 33556
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RINGO DAVID Manager 13266 BYRD DR, ODESSA, FL, 33556
RINGO DAVID Agent 686 Richmond Close, Tarpon Springs, FL, 34688

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
REGISTERED AGENT ADDRESS CHANGED 2019-11-07 686 Richmond Close, Tarpon Springs, FL 34688 -
REINSTATEMENT 2019-11-07 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2018-01-28 13266 BYRD DR, #1071, ODESSA, FL 33556 -
CHANGE OF MAILING ADDRESS 2018-01-28 13266 BYRD DR, #1071, ODESSA, FL 33556 -
REINSTATEMENT 2015-10-05 - -
REGISTERED AGENT NAME CHANGED 2015-10-05 RINGO, DAVID -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -
REINSTATEMENT 2014-10-05 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J22000150476 ACTIVE 2021-CA-002290-CAAX-WS PASCO COUNTY, FLORIDA 2022-02-17 2027-03-30 $261,604.37 FC MARKETPLACE, LLC, A DELAWARE LIMITED LIABILITY CO., 747 FRONT STREET, 4TH FLOOR, SAN FRANCISCO, CA 94111
J21000635338 ACTIVE 2021 SC 052527 O ORANGE CO 2021-11-19 2026-12-10 $6125.60 CITY ELECTRIC SUPPLY COMPANY, P.O. BOX 609521, ORLANDO, FLORIDA 32860
J21000475503 ACTIVE 2021-CA-001335 CIRCUIT COURT FOR PASCO COUNTY 2021-08-24 2026-09-22 $802,060.51 SYNOVUS BANK, 1111 BAY AVENUE, SYNOVUS CENTER, SUITE 401, COLUMBUS, GA 31901
J19000013258 ACTIVE 1000000809182 PASCO 2018-12-26 2039-01-02 $ 1,005.74 STATE OF FLORIDA, DEPARTMENT OF REVENUE, TAMPA SERVICE CENTER, 5483 W WATERS AVE STE 1210, TAMPA FL336341236

Documents

Name Date
ANNUAL REPORT 2020-04-05
REINSTATEMENT 2019-11-07
ANNUAL REPORT 2018-01-28
ANNUAL REPORT 2017-01-24
ANNUAL REPORT 2016-05-11
REINSTATEMENT 2015-10-05
REINSTATEMENT 2014-10-05
Florida Limited Liability 2013-01-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344637475 0420600 2020-02-19 3077 BROOK STONE TERRACE, DAVENPORT, FL, 33837
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2020-02-19
Emphasis L: FALL
Case Closed 2022-03-01

Related Activity

Type Referral
Activity Nr 1543088
Safety Yes
Type Complaint
Activity Nr 1543898
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2020-08-06
Abatement Due Date 2020-09-03
Current Penalty 6000.0
Initial Penalty 9446.0
Final Order 2020-09-03
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) On or about February 11, 2020, employees without personal protection were exposed to falls while performing tasks such as but not limited taking measurements and installing solar panels on a two story residential building approximately 10-24 feet from the ground
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2020-08-06
Abatement Due Date 2020-09-03
Current Penalty 6000.0
Initial Penalty 9446.0
Final Order 2020-09-03
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6): Ladders were used on surfaces which were not stable and level: a) On or about February 11, 2020, employees were exposed to falls while using two Werner Portable Ladders for accessing upper levels. One ladder was placed on top of a brick paver driveway to access first story overhang with S Tiles and the other ladder was placed on top of the first floor overhang with S Tiles to the second story roof.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B22
Issuance Date 2020-08-06
Abatement Due Date 2020-09-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-09-03
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: (a) On or about February 11, 2020, employees were exposed to falls when climbing portable ladders while carrying supplies and equipment needed for solar panel installation on a two story residential roof.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2020-08-06
Abatement Due Date 2020-08-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-09-03
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about February 11, 2020, for employees without fall protection installing solar panels on a two story residential roof with "S" style tiling.
Citation ID 02002
Citaton Type Other
Standard Cited 19261060 A
Issuance Date 2020-08-06
Abatement Due Date 2020-08-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-09-03
Nr Instances 2
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) On or about February 11, 2020, employees were exposed to falls while using two Werner Portable Ladders for accessing upper levels of a two story residential roof. For accessing to the first story, a ladder was placed on top of brick pavers driveway to "S" Tile overhang and the other ladder was placed on top of the first floor "S" Tile overhang to the second story roof.
343057907 0420600 2018-03-30 12048 LAKE BLVD, NEW PORT RICHEY, FL, 34652
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Close Conference 2018-03-30
Case Closed 2018-04-20

Related Activity

Type Complaint
Activity Nr 1323040
Safety Yes

Date of last update: 01 Apr 2025

Sources: Florida Department of State