Entity Name: | TAKA ELEVATOR COMPANY, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
TAKA ELEVATOR COMPANY, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 18 Jan 2013 (12 years ago) |
Last Event: | LC AMENDMENT |
Event Date Filed: | 18 Nov 2013 (11 years ago) |
Document Number: | L13000009538 |
FEI/EIN Number |
46-1806123
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 155 North Spring Trail, Altamonte Springs, FL, 32714, US |
Mail Address: | P.O. BOX 940161, MAITLAND, FL, 32794 |
ZIP code: | 32714 |
County: | Seminole |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
LALCHANDANI PATRICK | Managing Member | P.O. BOX 940161, MAITLAND, FL, 32794 |
Lalchandani Mary | Corp | P.O. BOX 940161, MAITLAND, FL, 32794 |
LALCHANDANI MARY R | Agent | 155 North Spring Trail, Altamonte Springs, FL, 32714 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2025-02-05 | 155 North Spring Trail, Altamonte Springs, FL 32714 | - |
REGISTERED AGENT ADDRESS CHANGED | 2025-02-05 | 155 North Spring Trail, Altamonte Springs, FL 32714 | - |
CHANGE OF PRINCIPAL ADDRESS | 2019-01-24 | 6130 EDGEWATER DR., STE. D, ORLANDO, FL 32810 | - |
REGISTERED AGENT ADDRESS CHANGED | 2019-01-24 | 6130 Edgewater Dr., Suite D, Orlando, FL 32810 | - |
LC AMENDMENT | 2013-11-18 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-02-05 |
ANNUAL REPORT | 2024-01-19 |
ANNUAL REPORT | 2023-01-30 |
ANNUAL REPORT | 2022-01-24 |
ANNUAL REPORT | 2021-03-15 |
ANNUAL REPORT | 2020-01-17 |
ANNUAL REPORT | 2019-01-24 |
AMENDED ANNUAL REPORT | 2018-05-02 |
ANNUAL REPORT | 2018-01-11 |
ANNUAL REPORT | 2017-01-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342972486 | 0419700 | 2018-02-15 | 7500 SW ARCHER DR MAYFAIR APARTMENTS, GAINESVILLE, FL, 32608 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1295539 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260405 A02 II E |
Issuance Date | 2018-03-23 |
Current Penalty | 2328.0 |
Initial Penalty | 3880.0 |
Final Order | 2018-04-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a. On or about February 15, 2018 employees working in the elevator shaft had installed temporary lighting from the first floor to the third floor, that was not protected from accidental contact or breakage. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260405 A02 II F |
Issuance Date | 2018-03-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-04-04 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension: a. On or about February 15, 2018 Employees working inside the elevator shaft had suspended a home made temporary lighting system from a sheet rock screw affixed to the side wall of the shaft on the third floor and draped the wires down the shaft to the first floor. At each light socket spliced to the wire a sheetrock screw affixed the wires to the wall. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260405 A02 II J |
Issuance Date | 2018-03-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-04-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(a)(2)(ii)(J): Flexible cords used with temporary and portable lights were not designed for hard or extra-hard usage: a. On or about February 15, 2018 Employees had utilized a home made temporary lighting system constructed with 16 gauge, 2 conductor non grounded SPT2 lamp wire, with medium base 2 wire temporary light sockets. The electric lamp wire was not deigned for hard or extra hard usage. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260502 B02 |
Issuance Date | 2018-03-23 |
Current Penalty | 3880.2 |
Initial Penalty | 6467.0 |
Final Order | 2018-04-04 |
Nr Instances | 2 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. a. On or about February 15, 2018 Employees working outside the elevator shaft on the 3rd and 2nd floors, were not protected by a guardrail system complete with midrails, exposing them to falls in excess of 30 feet to the pit floor below. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260502 B03 |
Issuance Date | 2018-03-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-04-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a. On or about February 15, 2018 employees working outside the elevator shaft were not protected from falling more than 30 feet to the elevator pit because the guardrail system positioned at the shaft openings were not affixed to the walls or to the shaft opening and could not withstand 200 pounds applied laterally to the guardrail system. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3264848504 | 2021-02-23 | 0491 | PPS | 6130 Edgewater Dr Ste D Ste D, Orlando, FL, 32810-4865 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1838697806 | 2020-05-22 | 0491 | PPP | 155 N SPRING TRAIL, ALTAMONTE SPRINGS, FL, 32714-3462 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 03 May 2025
Sources: Florida Department of State