Entity Name: | TREMRON, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
TREMRON, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 21 Dec 2012 (12 years ago) |
Last Event: | LC STMNT OF RA/RO CHG |
Event Date Filed: | 28 Aug 2017 (8 years ago) |
Document Number: | L12000160109 |
FEI/EIN Number |
65-0238002
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5 Concourse Pkwy, ATLANTA, GA, 30328-6111, US |
Mail Address: | 5 Concourse Pkwy, ATLANTA, GA, 30328-6111, US |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
David T. Jones | Manager | 5 Concourse Pkwy, ATLANTA, GA, 303286111 |
CORPORATE CREATIONS NETWORK INC. | Agent | - |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G13000047892 | TREMRON GROUP | EXPIRED | 2013-05-21 | 2018-12-31 | - | 2885 ST. CLAIR STREET, JACKSONVILLE, FL, 32254 |
G13000047893 | TREMRON ARCADIA | EXPIRED | 2013-05-21 | 2018-12-31 | - | 2885 ST. CLAIR STREET, JACKSONVILLE, FL, 32254 |
G13000047894 | TREMRON MIAMI | EXPIRED | 2013-05-21 | 2018-12-31 | - | 2885 ST. CLAIR STREET, JACKSONVILLE, FL, 32254 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT ADDRESS CHANGED | 2020-03-25 | 801 US HIGHWAY 1, NORTH PALM BEACH, FL 33408 | - |
LC STMNT OF RA/RO CHG | 2017-08-28 | - | - |
REGISTERED AGENT NAME CHANGED | 2017-08-28 | CORPORATE CREATIONS NETWORK INC. | - |
CHANGE OF PRINCIPAL ADDRESS | 2017-04-24 | 5 Concourse Pkwy, SUITE 1900, ATLANTA, GA 30328-6111 | - |
CHANGE OF MAILING ADDRESS | 2017-04-24 | 5 Concourse Pkwy, SUITE 1900, ATLANTA, GA 30328-6111 | - |
MERGER | 2016-12-22 | - | CORPORATION WAS A MERGER RESULT. TOTAL NUMBER OF QUALIFIED CORPORATION(S) INVOLVED WAS 2. MERGER NUMBER 900000166999 |
LC STMNT OF RA/RO CHG | 2016-05-24 | - | - |
CONVERSION | 2012-12-21 | - | CORPORATION WAS A CONVERSION RESULT. CONVERTING CORPORATION WAS S06378. CONVERSION NUMBER 300000127643 |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-15 |
ANNUAL REPORT | 2023-03-24 |
ANNUAL REPORT | 2022-03-11 |
ANNUAL REPORT | 2021-04-05 |
ANNUAL REPORT | 2020-03-12 |
ANNUAL REPORT | 2019-04-15 |
ANNUAL REPORT | 2018-03-02 |
CORLCRACHG | 2017-08-28 |
ANNUAL REPORT | 2017-04-24 |
Merger | 2016-12-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345566178 | 0419700 | 2021-10-06 | 2885 SAINT CLAIR STREET, JACKSONVILLE, FL, 32254 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1819149 |
Safety | Yes |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-07-20 |
Case Closed | 2015-11-27 |
Related Activity
Type | Inspection |
Activity Nr | 1080458 |
Safety | Yes |
Type | Referral |
Activity Nr | 1000735 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2015-10-26 |
Current Penalty | 2695.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-11-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to unguarded conveyor belt nip points: a) At the weigh belt area between the Block Plant and Paver Plant in the facility located on 1030 Airport Road, Lakeland, FL, an employee was pulled into the moving conveyor belt as he was performing general clean-up under the belt, on or about 07/13/2015. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100147 C04 I |
Issuance Date | 2015-10-26 |
Abatement Due Date | 2015-11-20 |
Current Penalty | 2695.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-11-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the weigh belt area between the Block Plant and Paver Plant in the facility located on 1030 Airport Road, Lakeland, FL, an employee was pulled into the moving conveyor belt as he was performing general clean-up under the belt. No procedures were implemented and/or enforced, on or about, 07/13/2015. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100147 C06 I |
Issuance Date | 2015-10-26 |
Abatement Due Date | 2015-11-20 |
Current Penalty | 2695.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-11-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the facility located on 1030 Airport Road, Lakeland, FL, the employer did not conduct periodic inspection when employees were authorized to perform maintenance/repair work in equipment, such as but not limited to, conveyor, on or about 07/13/15. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100147 C07 I B |
Issuance Date | 2015-10-26 |
Abatement Due Date | 2015-11-20 |
Current Penalty | 2695.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-11-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) At the facility located on 1030 Airport Road, Lakeland, FL, employees involved in the clean-up process under the weigh belt were not provided lock-out / tag-out training, on or about, 07/13/2015. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State