Search icon

EL TRONO CONSTRUCTION, LLC.

Company Details

Entity Name: EL TRONO CONSTRUCTION, LLC.
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Company
Status: Inactive
Date Filed: 26 Oct 2012 (12 years ago)
Date of dissolution: 23 Sep 2016 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (8 years ago)
Document Number: L12000136638
FEI/EIN Number 46-1272816
Address: 4839 CLARCONA RD, APT 1, ORLANDO, FL 32810
Mail Address: 4839 CLARCONA RD, APT 1, ORLANDO, FL 32810
ZIP code: 32810
County: Orange
Place of Formation: FLORIDA

Agent

Name Role Address
ECHEVARRIA PAGAN, SANTOS D Agent 3633 LATEMORNING CIR, KISSIMMEE, FL 34744

Manager

Name Role Address
ECHEVARRIA PAGAN, SANTOS D Manager 3633 LATEMORNING CIR, KISSIMMEE, FL 34744

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 No data No data
REINSTATEMENT 2015-08-10 No data No data
REGISTERED AGENT NAME CHANGED 2015-08-10 ECHEVARRIA PAGAN, SANTOS D No data
ADMIN DISSOLUTION FOR ANNUAL REPORT 2014-09-26 No data No data
REINSTATEMENT 2013-10-03 No data No data
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 No data No data

Documents

Name Date
REINSTATEMENT 2015-08-10
REINSTATEMENT 2013-10-03
Florida Limited Liability 2012-10-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339485880 0419700 2013-11-13 11453 JOHNSON CREEK CIRCLE - LOT 131, JACKSONVILLE, FL, 32208
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-11-13
Emphasis L: FALL, P: FALL
Case Closed 2018-09-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2013-12-09
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a. On or about November 13, 2013, the right side scaffold system was not fully planked on the first level and had gaps, exposing the employee to a 7.5 feet fall hazard. Abatement Certification and Documentation are not required
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2013-12-09
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about November 13, 2013, both two buck high scaffold systems were erected in the dirt, exposing the employees to crushing hazards. The legs and posts were not erected with mudsills or base plates. Abatement Certification and Documentation are not required
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-12-09
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-01-21
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a. On or about November 13, 2013, right side of the home, the two buck high scaffold system did not have a ladder. The employee climbed the rungs, exposing himself to a 7.5 feet fall hazard. b. On or about November 13, 2013, left side of the home, the two buck high scaffold system did not have a ladder. The employee climbed the rungs, exposing himself to a 9.5 feet fall hazard. Abatement Certification and Documentation are not required
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-12-09
Abatement Due Date 2014-01-06
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a. On or about November 13, 2013, both two buck high scaffold systems were not erected, moved or dismantled under the supervision of a competent person. Abatement Certification and Documentation are required
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-12-09
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On or about November 13, 2013, roof area, the employee standing on the roof plastering the exterior of a two-story home was not protected from falling 9.5 feet by the use of a guardrail system, safety net system or a personal fall arrest system. Abatement Certification and Documentation are not required

Date of last update: 22 Feb 2025