Search icon

PACIFIC STUCCO LLC - Florida Company Profile

Company Details

Entity Name: PACIFIC STUCCO LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

PACIFIC STUCCO LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 23 Oct 2012 (13 years ago)
Date of dissolution: 23 Sep 2016 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (9 years ago)
Document Number: L12000134946
FEI/EIN Number 46-1243856

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 12472 LAKE UNDERHILL RD, 157, ORLANDO, FL, 32828
Mail Address: 12472 LAKE UNDERHILL RD, 157, ORLANDO, FL, 32828
ZIP code: 32828
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ACEVEDO MARCO A Manager 12472 LAKE UNDERHILL RD STE 157, ORLANDO, FL, 32828
ACEVEDO MARCO A Agent 12472 LAKE UNDERHILL RD, ORLANDO, FL, 32828

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -

Documents

Name Date
ANNUAL REPORT 2015-03-20
ANNUAL REPORT 2014-01-09
ANNUAL REPORT 2013-04-10
Florida Limited Liability 2012-10-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340037068 0420600 2014-10-24 2681 ROOSEVELT BLVD., CLEARWATER, FL, 33760
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-10-24
Emphasis L: FALL, P: FALL
Case Closed 2017-10-25

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260453 B02 V
Issuance Date 2014-10-30
Abatement Due Date 2014-11-26
Current Penalty 6160.0
Initial Penalty 6160.0
Final Order 2014-11-28
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. Building 600 - during soffit operations, employees were not attached to the Genie S-65 S6012-22973 aerial lift basket and were exposed up to a 30' fall hazard. Violation observed on or about 10/24/14. The Pacific Stucco, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.453(b)(2)(v), which was contained in OSHA inspection number 944099, citation number 01, item number 001 and was affirmed as a final order on 12/18/13, with respect to a workplace located at 1600 Rinehart Rd. Sanford, Florida 32771.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2014-10-30
Abatement Due Date 2014-12-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-28
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. Building 600 - the employer did not implement a written respiratory protection program when employees were required to wear respirators. Violation observed on or about 10/24/14.
Citation ID 02002
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2014-10-30
Abatement Due Date 2014-12-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-28
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Building 600 - the employer did not provide medical evaluations when employees were required to wear respirators. Violation observed on or about 10/24/14.
Citation ID 02003
Citaton Type Other
Standard Cited 19100134 F01
Issuance Date 2014-10-30
Abatement Due Date 2014-12-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-28
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. Building 600 - the employer did not provide fit testing when employees were required to wear respirators. Violation observed on or about 10/24/14.
339670531 0420600 2014-04-08 115 NORTH ORLANDO AVE. BLDG A, ORLANDO, FL, 32807
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-04-08
Emphasis L: EISAOF, L: EISAX, L: FALL, P: FALL
Case Closed 2014-06-09

Related Activity

Type Inspection
Activity Nr 967058
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-05-08
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a). At building A of the Trader Joes construction site the third section of the supported scaffold where an employee was spraying was not fully planked exposing him to a 15-foot fall hazard on or about April 9, 2014.
339475139 0420600 2013-11-06 6405 CENTURY WAY, NEW PORT RICHEY, FL, 34654
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-11-06
Emphasis N: CTARGET, L: FALL, L: EISAOF, P: CTARGET
Case Closed 2014-07-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-12-17
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about 11-06-2013 at bldg #6405, a pump jack scaffold without any end guardrails was being used to install aluminium siding on the building. Employees were not attached by lanyard to the lifeline and were exposed to a 25 ft. fall hazard.
339440992 0420600 2013-09-25 1600 RINEHART ROAD, SANFORD, FL, 32771
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-09-26
Emphasis L: EISAOF, L: FALL, L: EISAX, P: FALL
Case Closed 2013-12-18

Related Activity

Type Inspection
Activity Nr 944082
Safety Yes
Type Inspection
Activity Nr 944074
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2013-11-21
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2013-12-17
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: (a) At the Clubhouse location an employee was elevated in the basket of the aerial lift without the use of fall protection while preparing to apply exterior siding as observed on or about September 25, 2013.