Entity Name: | PACIFIC STUCCO LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
PACIFIC STUCCO LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 23 Oct 2012 (13 years ago) |
Date of dissolution: | 23 Sep 2016 (9 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 23 Sep 2016 (9 years ago) |
Document Number: | L12000134946 |
FEI/EIN Number |
46-1243856
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 12472 LAKE UNDERHILL RD, 157, ORLANDO, FL, 32828 |
Mail Address: | 12472 LAKE UNDERHILL RD, 157, ORLANDO, FL, 32828 |
ZIP code: | 32828 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ACEVEDO MARCO A | Manager | 12472 LAKE UNDERHILL RD STE 157, ORLANDO, FL, 32828 |
ACEVEDO MARCO A | Agent | 12472 LAKE UNDERHILL RD, ORLANDO, FL, 32828 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2016-09-23 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2015-03-20 |
ANNUAL REPORT | 2014-01-09 |
ANNUAL REPORT | 2013-04-10 |
Florida Limited Liability | 2012-10-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340037068 | 0420600 | 2014-10-24 | 2681 ROOSEVELT BLVD., CLEARWATER, FL, 33760 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Repeat |
Standard Cited | 19260453 B02 V |
Issuance Date | 2014-10-30 |
Abatement Due Date | 2014-11-26 |
Current Penalty | 6160.0 |
Initial Penalty | 6160.0 |
Final Order | 2014-11-28 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. Building 600 - during soffit operations, employees were not attached to the Genie S-65 S6012-22973 aerial lift basket and were exposed up to a 30' fall hazard. Violation observed on or about 10/24/14. The Pacific Stucco, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.453(b)(2)(v), which was contained in OSHA inspection number 944099, citation number 01, item number 001 and was affirmed as a final order on 12/18/13, with respect to a workplace located at 1600 Rinehart Rd. Sanford, Florida 32771. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100134 C01 |
Issuance Date | 2014-10-30 |
Abatement Due Date | 2014-12-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-11-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. Building 600 - the employer did not implement a written respiratory protection program when employees were required to wear respirators. Violation observed on or about 10/24/14. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100134 E01 |
Issuance Date | 2014-10-30 |
Abatement Due Date | 2014-12-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-11-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Building 600 - the employer did not provide medical evaluations when employees were required to wear respirators. Violation observed on or about 10/24/14. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19100134 F01 |
Issuance Date | 2014-10-30 |
Abatement Due Date | 2014-12-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-11-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. Building 600 - the employer did not provide fit testing when employees were required to wear respirators. Violation observed on or about 10/24/14. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2014-04-08 |
Emphasis | L: EISAOF, L: EISAX, L: FALL, P: FALL |
Case Closed | 2014-06-09 |
Related Activity
Type | Inspection |
Activity Nr | 967058 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2014-05-08 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-06-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a). At building A of the Trader Joes construction site the third section of the supported scaffold where an employee was spraying was not fully planked exposing him to a 15-foot fall hazard on or about April 9, 2014. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2013-11-06 |
Emphasis | N: CTARGET, L: FALL, L: EISAOF, P: CTARGET |
Case Closed | 2014-07-09 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2013-12-17 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-01-15 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about 11-06-2013 at bldg #6405, a pump jack scaffold without any end guardrails was being used to install aluminium siding on the building. Employees were not attached by lanyard to the lifeline and were exposed to a 25 ft. fall hazard. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2013-09-26 |
Emphasis | L: EISAOF, L: FALL, L: EISAX, P: FALL |
Case Closed | 2013-12-18 |
Related Activity
Type | Inspection |
Activity Nr | 944082 |
Safety | Yes |
Type | Inspection |
Activity Nr | 944074 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2013-11-21 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-12-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: (a) At the Clubhouse location an employee was elevated in the basket of the aerial lift without the use of fall protection while preparing to apply exterior siding as observed on or about September 25, 2013. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State