Search icon

JSI CONSTRUCTION SERVICES LLC - Florida Company Profile

Company Details

Entity Name: JSI CONSTRUCTION SERVICES LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

JSI CONSTRUCTION SERVICES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 19 Oct 2012 (13 years ago)
Document Number: L12000133642
FEI/EIN Number 46-1207319

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2105 fairfield ave, Brandon, FL, 33510, US
Mail Address: 2105 fairfield ave, Brandon, FL, 33510, US
ZIP code: 33510
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CALVO-ALVAREZ JOHAN Managing Member 8352 alafia pointe dr, rivervew, FL, 33578
MONSALVE ISABEL Managing Member 8352 alafia pointe dr, Riverview, FL, 33578
MONSALVE ISABEL Agent 2105 Fairfield ave, Brandon, FL, 33510

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2025-02-08 2105 Fairfield ave, Brandon, FL 33510 -
CHANGE OF PRINCIPAL ADDRESS 2016-01-22 2105 fairfield ave, Brandon, FL 33510 -
CHANGE OF MAILING ADDRESS 2016-01-22 2105 fairfield ave, Brandon, FL 33510 -
REGISTERED AGENT ADDRESS CHANGED 2016-01-22 2105 Fairfield ave, Brandon, FL 33510 -

Documents

Name Date
ANNUAL REPORT 2025-02-08
ANNUAL REPORT 2024-04-29
ANNUAL REPORT 2023-01-18
ANNUAL REPORT 2022-03-02
ANNUAL REPORT 2021-02-03
ANNUAL REPORT 2020-03-17
ANNUAL REPORT 2019-03-30
ANNUAL REPORT 2018-03-07
ANNUAL REPORT 2017-02-10
ANNUAL REPORT 2016-01-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341228724 0420600 2016-02-03 25356 COPPERLEAF DRIVE, VENICE, FL, 34293
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-02-03
Emphasis L: FALL, P: FALL
Case Closed 2017-04-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-03-17
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. At the jobsite, the tubular welded scaffolding employees were working from was missing approximately 20 inches of planking on the working levels, exposing the employees to 5 foot fall hazard, on or about 2/3/16.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B04
Issuance Date 2016-03-17
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm): a. At the jobsite, the planking on the tubular welded scaffolding employees were working from extended approximately 2-1/2 inches past the support beam of the scaffold frame itself, exposing the employees to 5 foot fall hazard, on or about 2/3/16.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2016-03-17
Abatement Due Date 2016-03-29
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a. At the jobsite, employees erected, moved and worked from tubular welded scaffolding without a competent supervising the work, exposing the employees to a 5 foot fall hazard, on or about 2/3/16.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F14
Issuance Date 2016-03-17
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: a. At the jobsite, an employee working from a scaffold was standing on a concrete block so he could reach over the concrete wall that he was building, exposing the employee to a 7 foot fall hazard, on or about 2/3/16.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2016-03-17
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. At the jobsite, the tubular welded scaffolding employees were working from was not square and was missing bracing, exposing the employees to a 5 foot fall hazard, on or about 2/3/16.
Citation ID 02001
Citaton Type Other
Standard Cited 19261053 B04
Issuance Date 2016-03-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-29
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. At the jobsite, an employee was standing on the fourth step of a step ladder that was braced against a concrete wall, exposing the employee to a 3 foot fall hazard, on or about 2/3/16.