Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-09-22
|
Emphasis |
L: FALL
|
Related Activity
Type |
Complaint |
Activity Nr |
1949304 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B02 |
Issuance Date |
2022-11-18 |
Abatement Due Date |
2022-12-15 |
Current Penalty |
3729.0 |
Initial Penalty |
3729.0 |
Final Order |
2023-05-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(2):Scaffold platforms and walkways were not at least 18 inches wide a) On the site, located at 4345 Founders Club Dr., Sarasota, FL: On or about 09/22/2022, the employer exposed employees to fall hazards, in that the scaffold platforms on site were approximately 7 inches wide. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 B03 |
Issuance Date |
2022-11-18 |
Abatement Due Date |
2022-12-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-05-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(3):The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling. a) On the site, located at 4345 Founders Club Dr., Sarasota, FL: On or about 09/22/2022, the employer exposed employees to fall hazards, in that the scaffold platforms on site were approximately 19 inches from the face of the work. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2022-11-18 |
Abatement Due Date |
2022-12-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-05-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. a) On the site, located at 4345 Founders Club Dr., Sarasota, FL: On or about 09/22/2022, the employer exposed employees to fall hazards, in that the scaffolding being used on site was not inspected prior to each work shift. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2022-11-18 |
Abatement Due Date |
2022-12-15 |
Current Penalty |
4351.0 |
Initial Penalty |
4351.0 |
Final Order |
2023-05-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) a) On the roof of the site, located at 4345 Founders Club Dr., Sarasota, FL: On or about 09/22/2022, the employer exposed employees to fall hazards, in that employees were conducting work without the use of fall protection. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2022-11-18 |
Abatement Due Date |
2022-12-15 |
Current Penalty |
2486.0 |
Initial Penalty |
2486.0 |
Final Order |
2023-05-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) On the site, located at 4345 Founders Club Dr., Sarasota, FL: On or about 09/22/2022, the employer exposed employees to fall hazards, in that employees were using a ladder that was not extended at least 3 ft. above the landing surface of the scaffolding on site. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2022-11-18 |
Abatement Due Date |
2022-12-15 |
Current Penalty |
2486.0 |
Initial Penalty |
2486.0 |
Final Order |
2023-05-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed. a) On the site, located at 4345 Founders Club Dr., Sarasota, FL: On or about 09/22/2022, the employer exposed employees to fall hazards, in that employees were using an A frame ladder improperly |
|
|