Search icon

FLORIDA INNOVATION BUILDERS LLC - Florida Company Profile

Company Details

Entity Name: FLORIDA INNOVATION BUILDERS LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

FLORIDA INNOVATION BUILDERS LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Aug 2012 (13 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 17 Oct 2024 (5 months ago)
Document Number: L12000105689
FEI/EIN Number 46-0803933

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1306 WOODS LANDING DR, MINNIOLA, FL, 34715, US
Mail Address: 1306 WOODS LANDING DR, MINNIOLA, FL, 34715, US
ZIP code: 34715
County: Lake
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GODOI MERITON L Auth 1306 WOODS LANDING DR, MINNIOLA, FL, 34715
GODOI MERITON L Agent 1306 WOODS LANDING DR, MINNIOLA, FL, 34715

Events

Event Type Filed Date Value Description
REINSTATEMENT 2024-10-17 - -
REGISTERED AGENT NAME CHANGED 2024-10-17 GODOI, MERITON L -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
REGISTERED AGENT ADDRESS CHANGED 2019-04-29 1306 WOODS LANDING DR, MINNIOLA, FL 34715 -
CHANGE OF PRINCIPAL ADDRESS 2017-04-28 1306 WOODS LANDING DR, MINNIOLA, FL 34715 -
CHANGE OF MAILING ADDRESS 2017-04-28 1306 WOODS LANDING DR, MINNIOLA, FL 34715 -

Documents

Name Date
REINSTATEMENT 2024-10-17
ANNUAL REPORT 2023-04-24
ANNUAL REPORT 2022-03-08
ANNUAL REPORT 2021-08-24
ANNUAL REPORT 2020-06-18
ANNUAL REPORT 2019-04-29
ANNUAL REPORT 2018-05-01
ANNUAL REPORT 2017-04-28
ANNUAL REPORT 2016-09-14
ANNUAL REPORT 2015-04-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339030512 0419700 2013-04-25 500 PALM COAST PARKWAY SW, PALM COAST, FL, 32137
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-04-25
Emphasis N: CTARGET, P: CTARGET
Case Closed 2018-09-12

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-07-05
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: a. On or about April 25, 2013, all three levels of the scaffold system were not fully planked, exposing employees to a 16 feet fall hazard. Abatement Certification and Documentation are not required
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2013-07-05
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a. On or about April 25, 2013, the scaffold system legs and frames did not have base plates and mud sills, exposing employees to crushing hazards. Abatement Certification and Documentation are not required
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2013-07-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: a. On or about April 25, 2013, the scaffold system was not plumb in that two of the scaffold legs were in holes which left the scaffold system unlevel, exposing employees to a 16 feet fall hazard. Abatement Certification and Documentation are not required
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-07-05
Abatement Due Date 2013-08-21
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a. On or about April 25, 2013, the scaffold system was not erected, moved, dismantled or altered by a competent person. Abatement Certification and Documentation are required
Citation ID 01001E
Citaton Type Serious
Standard Cited 19260451 H01
Issuance Date 2013-07-05
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall: a. On or about April 25, 2013, all levels of the scaffold system did not have toeboards to protect employees from falling debris. Abatement Certification and Documentation are not required
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-07-05
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: On or about April 25, 2013, employees climbed the scaffold rungs because there was no ladder, exposing employees to a 16 feet fall hazard. Abatement Certification and Documentation are not required
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2013-07-05
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. On or about April 25, 2013, the scaffold system did not have endrails, exposing employees to a 16 feet fall hazard. Abatement Certification and Documentation are not required
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2013-07-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-06
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a. On or about April 25, 2013, guardrails were not installed along all open sides and ends of the scaffold platform system, exposing employees to a 16 feet fall hazard. Abatement Certification and Documentation are not required

Date of last update: 03 Mar 2025