Entity Name: | PROJECTS UNLIMITED SERVICES LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
PROJECTS UNLIMITED SERVICES LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 31 Jul 2012 (13 years ago) |
Date of dissolution: | 27 Sep 2019 (6 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2019 (6 years ago) |
Document Number: | L12000098607 |
FEI/EIN Number |
460699312
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5832 FISH CROW PL, LAND O LAKES, FL, 34638, US |
Mail Address: | 5832 FISH CROW PL, LAND O LAKES, FL, 34638, US |
ZIP code: | 34638 |
County: | Pasco |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
BONELLI CESAR | Managing Member | 5832 FISH CROW PL, LAND O LAKES, FL, 34638 |
Bonelli Cesar | Agent | 5860 150TH AV N, CLEARWATER, FL, 33760 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
REGISTERED AGENT NAME CHANGED | 2018-01-24 | Bonelli, Cesar | - |
REINSTATEMENT | 2018-01-23 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2016-09-23 | - | - |
REINSTATEMENT | 2014-12-09 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2014-12-09 | 5832 FISH CROW PL, LAND O LAKES, FL 34638 | - |
CHANGE OF MAILING ADDRESS | 2014-12-09 | 5832 FISH CROW PL, LAND O LAKES, FL 34638 | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2014-09-26 | - | - |
Name | Date |
---|---|
AMENDED ANNUAL REPORT | 2018-01-24 |
REINSTATEMENT | 2018-01-23 |
ANNUAL REPORT | 2015-05-20 |
REINSTATEMENT | 2014-12-09 |
AMENDED ANNUAL REPORT | 2013-10-30 |
ANNUAL REPORT | 2013-05-01 |
Florida Limited Liability | 2012-07-31 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339935090 | 0420600 | 2014-09-05 | ON BURYL COURT IN MEADWOOD SUBDIVISION, TEMPLE TERRACE, FL, 33637 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2014-09-17 |
Abatement Due Date | 2014-09-24 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-10-24 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For the roofing work being done on Buryl Court in Meadowood subdivision, Temple Terrace, FL as observed on or about 09/05/2014, employees were exposed to fall hazards of up to 17ft. 11in. No fall protection was being used on site. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2014-09-17 |
Abatement Due Date | 2014-10-06 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-10-24 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) For the roofing jobsite on Buryl Court in Meadowood subdivision, Temple Terrace, FL as observed on or about 09/05/2014, employees working on the roof and exposed to fall hazards had not received fall protection training and were not able to recognize fall hazards on site. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2014-09-17 |
Abatement Due Date | 2014-10-06 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-10-24 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) For the roofing work being done at Buryl Court in Meadowood subdivision, Temple Terrace, FL as observed on or about 09/05/2014, employees were not provided with ladder safety training and were observed using extension ladders to access roofs when the ladders did not extend three feet above the roof edge. Ladders were also setup on sloped roof sections where they could potentially slide resulting in fall hazards to employees. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State