Entity Name: | CANAVERAL PLASTERING SERVICES LLC |
Jurisdiction: | FLORIDA |
Filing Type: | Florida Limited Liability Co. |
Status: | Active |
Date Filed: | 18 Jun 2012 (13 years ago) |
Document Number: | L12000080863 |
FEI/EIN Number | 45-5615038 |
Address: | 4528 Sir Page Ln, TITUSVILLE, FL, 32796, US |
Mail Address: | 4528 Sir Page Ln, TITUSVILLE, FL, 32796, US |
ZIP code: | 32796 |
County: | Brevard |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
BENI JOHN | Agent | 4528 SIR PAGE LANE, TITUSVILLE, FL, 32796 |
Name | Role | Address |
---|---|---|
BENI JOHN | President | 4528 SIR PAGE LANE, TITUSVILLE, FL, 32796 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2023-04-26 | 4528 Sir Page Ln, TITUSVILLE, FL 32796 | No data |
CHANGE OF MAILING ADDRESS | 2023-04-26 | 4528 Sir Page Ln, TITUSVILLE, FL 32796 | No data |
Name | Date |
---|---|
ANNUAL REPORT | 2024-08-25 |
ANNUAL REPORT | 2023-04-26 |
ANNUAL REPORT | 2022-04-25 |
ANNUAL REPORT | 2021-04-19 |
ANNUAL REPORT | 2020-02-13 |
ANNUAL REPORT | 2019-03-19 |
ANNUAL REPORT | 2018-04-16 |
ANNUAL REPORT | 2017-04-28 |
ANNUAL REPORT | 2016-04-26 |
ANNUAL REPORT | 2015-02-26 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345585962 | 0419730 | 2021-10-05 | 605 CENTRAL BLVD W, CAPE CANAVERAL, FL, 32920 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1818227 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1556516 |
Safety | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2013-11-29 |
Emphasis | L: EISAOF, L: FALL, P: FALL |
Case Closed | 2016-12-13 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2014-02-11 |
Current Penalty | 1200.0 |
Initial Penalty | 1200.0 |
Final Order | 2014-03-11 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) At the site - an employee was walking on two wood planks carrying buckets of cement 7 feet high, creating a fall hazard on or about 11/29/13 |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2012-11-19 |
Emphasis | L: EISAOF, P: FALL, L: FALL |
Case Closed | 2017-12-04 |
Related Activity
Type | Inspection |
Activity Nr | 748988 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 I |
Issuance Date | 2013-01-08 |
Current Penalty | 1020.0 |
Initial Penalty | 1020.0 |
Final Order | 2013-02-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a.) On or about November 13, 2012, the tubular supported scaffold erected to a height of 16 feet was not fully planked exposing employees to fall hazards from the first and second level scaffold platforms. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2013-01-08 |
Current Penalty | 1020.0 |
Initial Penalty | 1020.0 |
Final Order | 2013-02-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. (a.) On or about November 13, 2012, the tubular scaffold erected to a height of 7 feet was not provided with a complete guardrail system exposing employees to a fall hazard. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3028818101 | 2020-07-14 | 0455 | PPP | 1763 Robinhood Avenue, Titusville, FL, 32796 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|