Search icon

PROTOTYPE PLASTICS, LLC - Florida Company Profile

Company Details

Entity Name: PROTOTYPE PLASTICS, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

PROTOTYPE PLASTICS, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 10 May 2012 (13 years ago)
Date of dissolution: 26 Mar 2018 (7 years ago)
Last Event: LC VOLUNTARY DISSOLUTION
Event Date Filed: 26 Mar 2018 (7 years ago)
Document Number: L12000063423
FEI/EIN Number 45-5252326

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3637 131ST ST AVE N, CLEARWATER, FL, 33762, US
Mail Address: 3637 131ST ST AVE N, CLEARWATER, FL, 33762, US
ZIP code: 33762
County: Pinellas
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Tisdale Michael P Manager 1523 Edgar Pl, Sarasota, FL, 34240
WALTER MIKE J Agent 3909 E BAY DR, HOLMES BEACH, FL, 34217

Events

Event Type Filed Date Value Description
LC VOLUNTARY DISSOLUTION 2018-03-26 - -

Documents

Name Date
LC Voluntary Dissolution 2018-03-26
AMENDED ANNUAL REPORT 2017-11-08
ANNUAL REPORT 2017-02-27
ANNUAL REPORT 2016-02-11
ANNUAL REPORT 2015-04-01
ANNUAL REPORT 2014-01-09
ANNUAL REPORT 2013-02-13
Florida Limited Liability 2012-05-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340932268 0420600 2015-09-18 3637 131ST. AVE. N., CLEARWATER, FL, 33762
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-09-18
Emphasis L: EISAOF, L: EISAX, N: AMPUTATE, P: AMPUTATE
Case Closed 2015-12-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2015-11-04
Abatement Due Date 2015-12-02
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-12-01
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) At the site - in the manufacturing plant area the Focus Saw was not attached to the floor to prevent tipping during operation, on or about 09/18/2015. (b) At the site - in the manufacturing area the Delta Drill Press was not attached to the floor to prevent tipping during operation, on or about 09/8/2015.
Citation ID 02001
Citaton Type Other
Standard Cited 19100133 A01
Issuance Date 2015-11-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-01
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) At the site - in the manufacturing area the employer did not provide employees with eye protection when using the grinder, on or about 09/18/2015.
Citation ID 02002
Citaton Type Other
Standard Cited 19100305 B01
Issuance Date 2015-11-04
Abatement Due Date 2015-12-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-01
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) At the site - in the manufacturing area the floor fan was plugged into a metal outlet with open knockouts, on or about 09/18/2015.

Date of last update: 01 Apr 2025