Entity Name: | PROTOTYPE PLASTICS, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
PROTOTYPE PLASTICS, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 10 May 2012 (13 years ago) |
Date of dissolution: | 26 Mar 2018 (7 years ago) |
Last Event: | LC VOLUNTARY DISSOLUTION |
Event Date Filed: | 26 Mar 2018 (7 years ago) |
Document Number: | L12000063423 |
FEI/EIN Number |
45-5252326
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 3637 131ST ST AVE N, CLEARWATER, FL, 33762, US |
Mail Address: | 3637 131ST ST AVE N, CLEARWATER, FL, 33762, US |
ZIP code: | 33762 |
County: | Pinellas |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Tisdale Michael P | Manager | 1523 Edgar Pl, Sarasota, FL, 34240 |
WALTER MIKE J | Agent | 3909 E BAY DR, HOLMES BEACH, FL, 34217 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
LC VOLUNTARY DISSOLUTION | 2018-03-26 | - | - |
Name | Date |
---|---|
LC Voluntary Dissolution | 2018-03-26 |
AMENDED ANNUAL REPORT | 2017-11-08 |
ANNUAL REPORT | 2017-02-27 |
ANNUAL REPORT | 2016-02-11 |
ANNUAL REPORT | 2015-04-01 |
ANNUAL REPORT | 2014-01-09 |
ANNUAL REPORT | 2013-02-13 |
Florida Limited Liability | 2012-05-10 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340932268 | 0420600 | 2015-09-18 | 3637 131ST. AVE. N., CLEARWATER, FL, 33762 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 B |
Issuance Date | 2015-11-04 |
Abatement Due Date | 2015-12-02 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2015-12-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) At the site - in the manufacturing plant area the Focus Saw was not attached to the floor to prevent tipping during operation, on or about 09/18/2015. (b) At the site - in the manufacturing area the Delta Drill Press was not attached to the floor to prevent tipping during operation, on or about 09/8/2015. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100133 A01 |
Issuance Date | 2015-11-04 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-12-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) At the site - in the manufacturing area the employer did not provide employees with eye protection when using the grinder, on or about 09/18/2015. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100305 B01 |
Issuance Date | 2015-11-04 |
Abatement Due Date | 2015-12-02 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-12-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) At the site - in the manufacturing area the floor fan was plugged into a metal outlet with open knockouts, on or about 09/18/2015. |
Date of last update: 01 Apr 2025
Sources: Florida Department of State