Entity Name: | MIDASCO, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
MIDASCO, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 24 Apr 2012 (13 years ago) |
Date of dissolution: | 09 Nov 2022 (2 years ago) |
Last Event: | LC VOLUNTARY DISSOLUTION |
Event Date Filed: | 09 Nov 2022 (2 years ago) |
Document Number: | L12000055254 |
FEI/EIN Number |
20-3908361
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 200 HARRY S TRUMAN PARKWAY, ANNAPOLIS, MD, 21401, US |
Mail Address: | 200 HARRY S TRUMAN PARKWAY, ANNAPOLIS, MD, 21401, US |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
CORPORATION SERVICE COMPANY | Agent | - |
Sadaka Shanon | Othe | 200 HARRY S TRUMAN PARKWAY, ANNAPOLIS, MD, 21401 |
Fernandez Alberto | President | 200 HARRY S TRUMAN PARKWAY, ANNAPOLIS, MD, 21401 |
Kleiss Jeffrey | Regi | 200 HARRY S TRUMAN PARKWAY, ANNAPOLIS, MD, 21401 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
LC VOLUNTARY DISSOLUTION | 2022-11-09 | - | - |
REGISTERED AGENT NAME CHANGED | 2021-12-14 | CORPORATION SERVICE COMPANY | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2021-09-24 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2020-06-16 | 200 HARRY S TRUMAN PARKWAY, SUITE 402, ANNAPOLIS, MD 21401 | - |
CHANGE OF MAILING ADDRESS | 2020-06-16 | 200 HARRY S TRUMAN PARKWAY, SUITE 402, ANNAPOLIS, MD 21401 | - |
Name | Date |
---|---|
LC Voluntary Dissolution | 2022-11-09 |
ANNUAL REPORT | 2022-01-26 |
REINSTATEMENT | 2021-12-14 |
ANNUAL REPORT | 2020-06-16 |
ANNUAL REPORT | 2019-03-27 |
ANNUAL REPORT | 2018-03-09 |
ANNUAL REPORT | 2017-03-17 |
ANNUAL REPORT | 2016-03-09 |
ANNUAL REPORT | 2015-04-24 |
AMENDED ANNUAL REPORT | 2014-11-03 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342695848 | 0418800 | 2017-10-11 | 1550 NW 37TH AVENUE, MIAMI, FL, 33126 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1272908 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-03-23 |
Current Penalty | 11641.0 |
Initial Penalty | 11641.0 |
Final Order | 2018-03-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall and struck-by hazards: On 10/11/2017, at the above addressed work site, the truck mounted crane's automatic rotation lock out system had been modified (hotwired) providing a constant 12-Volts to the turn motor solenoid, which allowed the boom to continue to operate when a pick is being conducted with the outriggers not fully extended. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 01001B |
Citaton Type | Other |
Standard Cited | 19261412 D01 I |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-03-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1412(d)(1)(i): Control mechanisms were not checked for maladjustments which would interfere with proper operation each shift: On or about 10/11/2017, at the above addressed work site, the employer did not ensure a competent person conducted daily inspections that included checking the control mechanisms for the boom not to exceed its swing radius when outriggers are not fully extended. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261416 E05 I |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-03-23 |
Current Penalty | 11641.0 |
Initial Penalty | 11641.0 |
Final Order | 2018-03-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1416(e)(5)(i): The operator did not verify that the position of the outriggers or stabilizers was correct (in accordance with manufacturer procedures) before beginning operations requiring outrigger or stabilizer deployment: On or about 10/11/2017, at the above addressed work site, an employee operating a crane mounted truck did not position the outriggers on the side of the pick in accordance with the manufacturer's procedures. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 01002B |
Citaton Type | Other |
Standard Cited | 19261417 U02 I |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-03-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1417(u)(2)(i): A competent person did not supervise the operation, determine if it was necessary to reduce rated capacity, or made determinations regarding the load position, boom location, ground support, travel route, overhead obstructions, and speed of movement necessary to ensure safety: On or about 10/11/2017, at the above addressed work site, the competent person supervising the operation did not make determination to stop the operation and have the crane operator move his truck in the center of the road to be able to fully extend the outriggers on both sides of the truck mounted crane. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 02001A |
Citaton Type | Other |
Standard Cited | 19261427 B01 III |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-04-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-26 |
Nr Instances | 1 |
Nr Exposed | 9 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1427(b)(1)(iii): The employer did not have procedures for operators to re-apply and be re-tested in the event an operator applicant fails a test or is decertified: On or about 10/11/2017, at the above addressed work site, the employer did not implement procedures for operators to re-apply and be re-tested when failing the certification tests in September of 2017. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 02001B |
Citaton Type | Other |
Standard Cited | 19261430 G02 |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-04-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-26 |
Nr Instances | 1 |
Nr Exposed | 9 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1430(g)(2): The employer did not provide refresher training in relevant topics for each employee when, based on the conduct of the employee or an evaluation of the employee's knowledge, there is an indication that retraining is necessary: On or about 10/11/2017, at the above addressed work site, the employer did not provide refresher training in relevant topics for each employee that failed the exams in September of 2017. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |