Search icon

BRANCO PREMIER STUCCO LLC - Florida Company Profile

Company Details

Entity Name: BRANCO PREMIER STUCCO LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

BRANCO PREMIER STUCCO LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 09 Apr 2012 (13 years ago)
Date of dissolution: 30 Mar 2022 (3 years ago)
Last Event: LC VOLUNTARY DISSOLUTION
Event Date Filed: 30 Mar 2022 (3 years ago)
Document Number: L12000048282
FEI/EIN Number 45-5007909

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 9484 BOGGY CREEK ROAD, ORLANDO, FL, 32824, US
Mail Address: 9484 BOGGY CREEK ROAD, ORLANDO, FL, 32824, US
ZIP code: 32824
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BRANCO MICHAEL B President 9484 BOGGY CREEK ROAD, ORLANDO, FL, 32824
B1 HOLDCO LLC Managing Member -
LOSEY PLLC Agent -

Events

Event Type Filed Date Value Description
LC VOLUNTARY DISSOLUTION 2022-03-30 - -
REGISTERED AGENT NAME CHANGED 2020-05-18 Losey PLLC -
REGISTERED AGENT ADDRESS CHANGED 2020-05-18 1420 Edgewater Dr., Orlando, FL 32804 -
CHANGE OF PRINCIPAL ADDRESS 2018-10-04 9484 BOGGY CREEK ROAD, ORLANDO, FL 32824 -
CHANGE OF MAILING ADDRESS 2018-10-04 9484 BOGGY CREEK ROAD, ORLANDO, FL 32824 -
LC AMENDMENT 2012-04-30 - -

Documents

Name Date
LC Voluntary Dissolution 2022-03-30
ANNUAL REPORT 2021-03-12
AMENDED ANNUAL REPORT 2020-05-18
ANNUAL REPORT 2020-02-24
ANNUAL REPORT 2019-04-01
ANNUAL REPORT 2018-03-07
ANNUAL REPORT 2017-04-07
ANNUAL REPORT 2016-02-03
ANNUAL REPORT 2015-01-13
ANNUAL REPORT 2014-03-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340728070 0419700 2015-06-24 10135 BEDFORD LAKES CT., JACKSONVILLE, FL, 32222
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-06-24
Emphasis L: EISAOF, L: FALL, P: FALL
Case Closed 2015-11-25

Related Activity

Type Inspection
Activity Nr 1072819
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2015-07-09
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2015-07-03
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a. On or about June 24, 2015, an employee using a NR83A2 Hitachi pneumatic nail gun was not wearing safety glasses, exposing himself to being hit by nails or flying debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-07-09
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-07-03
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about June 24, 2015, on a 4:12 pitch gable, an employee performing lathing operations was not protected from a 9-foot 10-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2015-07-09
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-07-03
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about June 24, 2015, an employee used a 6-foot a-frame improperly, in that the ladder was positioned on a 4:12 pitch lower roof, being used in the closed position, exposing the employee to a 9-foot 10-inch fall hazard.
339859258 0420600 2014-07-21 9260 CORTEZ BLVD., SPRING HILL, FL, 34613
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-07-21
Emphasis L: FALL, P: FALL
Case Closed 2014-09-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-08-15
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-09-09
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds used was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) On or about 07/21/2014 at the west corner of building #9260, the scaffold was not fully planked while the employees were applying stucco to the walls of the shopping center building. Employees were exposed to a 19 ft. fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2014-08-15
Abatement Due Date 2014-08-21
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-09-09
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: On or about 07/21/2014 at the west corner of building #9260, a sectional scaffold system had missing ends and mid-guardrails on all levels while employees were applying stucco to the building. Employees were exposed to a 19 ft. fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260451 H02 II
Issuance Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-09
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about 07/21/2014 at the west corner of building #9260, employees were exposed to a struck-by hazard, in that, toe boards were missing where there were employees working on the lower levels of a scaffold system.
337285845 0420600 2012-11-08 4508 SAVANNAH HOLLY PL, TAMPA, FL, 33619
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-11-08
Emphasis L: FALL, L: EISAX, P: FALL, L: EISAOF
Case Closed 2013-01-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2012-11-28
Abatement Due Date 2012-12-04
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2013-01-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). (a) At the site, employees were exposed to a 12 foot fall hazards, in that, a tubular welded frame scaffold two frames high was not fully planked during stucco operations.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-11-28
Abatement Due Date 2012-12-04
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2013-01-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: (a) At the site, employees were exposed to a 12 foot fall hazard while gaining access to a tubular welded frame scaffold two frames high, in that, a ladder or any other means of access was not provided.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2012-11-28
Abatement Due Date 2012-12-04
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2013-01-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. (a) At the site, employees were exposed to a 12 foot fall hazard while working from a tubular welded frame scaffold, two frames high, that was not protected with guardrails.

Date of last update: 01 Apr 2025