Search icon

STONY BROOK STRUCTURES OF FLORIDA, L.L.C. - Florida Company Profile

Company Details

Entity Name: STONY BROOK STRUCTURES OF FLORIDA, L.L.C.
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

STONY BROOK STRUCTURES OF FLORIDA, L.L.C. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 21 Oct 2011 (14 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 25 Sep 2017 (8 years ago)
Document Number: L11000120542
FEI/EIN Number 453646604

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2009 Tally Road, Leesburg, FL, 34748, US
Mail Address: 652 Scott Ave, Calverton, NY, 11933, US
ZIP code: 34748
County: Lake
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SCAIFE ELLA Vice President 2950 COUNTY ROAD 561, TAVARES, FL, 32778
Scaife Graham Owne 652 SCOTT AVE, Calverton, NY, 11933
SCAIFE GRAHAM Agent 2009 Tally Road, Leesburg, FL, 34748

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2021-04-02 2009 Tally Road, Leesburg, FL 34748 -
REGISTERED AGENT ADDRESS CHANGED 2021-04-02 2009 Tally Road, Leesburg, FL 34748 -
REINSTATEMENT 2017-09-25 - -
REGISTERED AGENT NAME CHANGED 2017-09-25 SCAIFE, GRAHAM -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 - -
LC AMENDMENT 2016-09-26 - -
CHANGE OF MAILING ADDRESS 2016-01-27 2009 Tally Road, Leesburg, FL 34748 -

Documents

Name Date
ANNUAL REPORT 2024-02-28
ANNUAL REPORT 2023-04-12
ANNUAL REPORT 2022-02-25
ANNUAL REPORT 2021-04-02
ANNUAL REPORT 2020-06-24
ANNUAL REPORT 2019-09-12
ANNUAL REPORT 2018-05-01
REINSTATEMENT 2017-09-25
LC Amendment 2016-09-26
ANNUAL REPORT 2016-01-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346046253 0420600 2022-06-28 2009 TALLY RD., LEESBURG, FL, 34748
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-06-28
Emphasis L: FORKLIFT
Case Closed 2023-01-31

Related Activity

Type Complaint
Activity Nr 1907633
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2022-08-03
Abatement Due Date 2022-08-29
Current Penalty 2175.5
Initial Penalty 4351.0
Final Order 2022-08-30
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that forklifts were operated without seat belts being used or in place. This condition exposed employees to struck-by/crushing hazards. a) For the shop and yard area, on or about 6/28/2022 and at times prior to, the employer exposed employees to struck-by/crushing hazards, in that, forklifts operated on site did not have seat belts.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2022-08-03
Current Penalty 1554.0
Initial Penalty 3108.0
Final Order 2022-08-30
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) For forklift operation in the shop and yard, on or about 06/28/2022 and at times prior to, the employer exposed employees to potential struck-by hazards, in that, an employee operating propane, sit-down forklifts had not been through a training or evaluation within the last three years.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100178 Q01
Issuance Date 2022-08-03
Current Penalty 2175.5
Initial Penalty 4351.0
Final Order 2022-08-30
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(1):Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: a) For the shop and yard area, on or about 06/28/2022 and at times prior to, the employer exposed employees to potential struck-by hazards, in that, forklifts were used with brakes that were in need of adjustment and did not adequately stop the forklifts.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100243 C01
Issuance Date 2022-08-03
Current Penalty 2175.5
Initial Penalty 4351.0
Final Order 2022-08-30
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.243(c)(1):Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a): a) For the shop location, on or about 06/28/2022 and at times prior to, the employer exposed employees to contact/shrapnel hazards, in that, portable grinders were used without safety guards to grind material on site.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2022-08-03
Current Penalty 1243.0
Initial Penalty 2486.0
Final Order 2022-08-30
Nr Instances 2
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For electrical extension cords in service at the shop, on or about 06/28/2022, the employer exposed employees to potential electric shock and burn hazards, in that, the outer insulation of the cords were damaged, exposing the cords inner wiring.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2022-08-03
Current Penalty 1554.0
Initial Penalty 3108.0
Final Order 2022-08-30
Nr Instances 2
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) For the compressor on the east side of the shop, on or about 06/28/2022 and at times prior to, the employer exposed employees to electrical shock hazards, in that, 220 VAC wiring was exposed at a junction box for the compressor. b) For the compressor on the west side of the shop, on or about 06/28/2022 and at times prior to, the employer exposed employees to electrical shock hazards, in that, 220 VAC wiring was exposed at a junction box for the compressor.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2022-08-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-08-30
Nr Instances 2
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) For the compressor on the east side of the shop, on or about 06/28/2022 and at times prior to, the employer exposed employees to electrical shock hazards, in that, 220 VAC wiring was exposed at a junction box for the compressor which had a cover that did not close. b) For the compressor on the west side of the shop, on or about 06/28/2022 and at times prior to, the employer exposed employees to electrical shock hazards, in that, 220 VAC wiring was exposed at a junction box for the compressor which was missing a cover.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100305 G02 II
Issuance Date 2022-08-03
Current Penalty 1243.0
Initial Penalty 2486.0
Final Order 2022-08-30
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(ii):Flexible cords were not used only in continuous lengths without splice or tap: a) For the shop area where the portable fan was located, on or about 06/28/2022 and at times prior to, the employer exposed employees to potential electric shock hazards, in that, the power cord to a fan was damaged and spliced with wire nuts and tape.
Citation ID 01008
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2022-08-03
Current Penalty 1243.0
Initial Penalty 2486.0
Final Order 2022-08-30
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) For the Uni-Hydro 120-24 Ironworker, on or about 06/28/2022 and at times prior to, the employer exposed employees to potential shock hazards, in that, the power cord for its foot pedal was lacking strain relief. b) For extension cords used with power tools at the shop, on or about 06/28/2022 and at times prior to, the employer exposed employees to potential shock/burn hazards, in that, strain relief was not provided at the cord's plug due to the outer insulation being pulled away at the plug.
Citation ID 02001
Citaton Type Other
Standard Cited 19030002 A01
Issuance Date 2022-08-03
Current Penalty 174.5
Initial Penalty 349.0
Final Order 2022-08-30
Nr Instances 1
Nr Exposed 8
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.2(a)(1):The employer did not ensure that a notice describing employee rights under the OSH Act was posted in a conspicuous place: a) For the shop location, on or about 06/28/2022, the required OSHA poster was not posted in a conspicuous place for employees to see.

Date of last update: 01 May 2025

Sources: Florida Department of State