Entity Name: | ATLANTIC COAST CONTRACTORS L.L.C. |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
ATLANTIC COAST CONTRACTORS L.L.C. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 20 Dec 2010 (14 years ago) |
Date of dissolution: | 23 Sep 2022 (3 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 23 Sep 2022 (3 years ago) |
Document Number: | L10000129469 |
FEI/EIN Number |
35-2457862
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2850 SW 16TH STREET, FORT LAUDERDALE, FL, 33312, US |
Mail Address: | 2850 SW 16TH STREET, FORT LAUDERDALE, FL, 33312, US |
ZIP code: | 33312 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
HARDY STEVEN C | Manager | 2850 SW 16TH STREET, FORT LAUDERDALE, FL, 33312 |
HARDY STEVEN C | Agent | 2850 SW 16TH STREET, FORT LAUDERDALE, FL, 33312 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2022-09-23 | - | - |
REINSTATEMENT | 2019-10-02 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
REGISTERED AGENT NAME CHANGED | 2015-10-22 | HARDY, STEVEN C | - |
REINSTATEMENT | 2015-10-22 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2015-09-25 | - | - |
REINSTATEMENT | 2013-10-05 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2013-09-27 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2012-10-22 | 2850 SW 16TH STREET, FORT LAUDERDALE, FL 33312 | - |
REINSTATEMENT | 2012-10-22 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2021-02-27 |
ANNUAL REPORT | 2020-06-07 |
REINSTATEMENT | 2019-10-02 |
ANNUAL REPORT | 2018-08-07 |
ANNUAL REPORT | 2017-04-25 |
ANNUAL REPORT | 2016-04-28 |
REINSTATEMENT | 2015-10-22 |
ANNUAL REPORT | 2014-08-30 |
REINSTATEMENT | 2013-10-05 |
REINSTATEMENT | 2012-10-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342576113 | 0418800 | 2017-08-18 | 2900 E. COMMERCIAL BLVD., FORT LAUDERDALE, FL, 33308 | |||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2017-10-02 |
Current Penalty | 2716.0 |
Initial Penalty | 2716.0 |
Final Order | 2017-11-01 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: On or about 18 August, 2017, at the above addressed job site, two employees were painting and waterproofing the roof of a building without the use of fall protection, exposing the employees to a fall hazard of up to approximately 20 feet. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State