Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-04
|
Emphasis |
L: EISAOF, L: EISAX
|
Case Closed |
2016-06-29
|
Related Activity
Type |
Complaint |
Activity Nr |
988778 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2015-08-10 |
Current Penalty |
612.0 |
Initial Penalty |
1020.0 |
Final Order |
2015-09-03 |
Nr Instances |
3 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a) In the fabrication area, on top of, in between and underneath equipment as well as the floor, a wood dusting and accumulated saw dust piles were observed, on or about June 04, 2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100213 D01 |
Issuance Date |
2015-08-10 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-09-03 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) by employees in the fabrication who were using a Delta and/or Powermatic table saws without guarding, on or about June 04, 2015. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2015-08-10 |
Current Penalty |
1224.0 |
Initial Penalty |
2040.0 |
Final Order |
2015-09-03 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) In the fabrication area, employees used compress air for cleaning cut wood and equipment with a reading of 70 p.s.i. , on or about June 4, 2015. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2015-08-10 |
Abatement Due Date |
2015-08-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-03 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) In the fabrication area, employees were using 3M Tekk Protection 8210 Plus, two straps disposable N95 respirators, while performing cutting, sanding or applying adhesives, on or about June 4, 2015. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100304 B03 II C 3 |
Issuance Date |
2015-08-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug were not visually inspected before use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage, and equipment found damaged or defective was not removed from use until repaired: a) In the fabrication area, a damage extension cord was being used to provide power to the dust collection system for the Delta Slider 3200 table saw, as observed on June 4, 2015. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2015-08-10 |
Abatement Due Date |
2015-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-03 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) In the fabrication area, employees used chemicals, such as but not limited to, Bostic GlideCote , contact cements, glues and paints, on or about June 4, 2015. |
|
|