Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-01-12
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-09-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1294343 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1289865 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1290024 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1321780 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1294206 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1294198 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1294380 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 II |
Issuance Date |
2018-07-09 |
Abatement Due Date |
2018-08-02 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-08-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: On or about January 12, 2018, at the above addressed jobsite, employees were observed operating a suspension scaffold, for the purpose of applying stucco, paint and water proofing to all four exterior walls of a new high-rise apartment building, during which the employees were not protected by both a personal fall arrest system and a guardrail system; therefore exposing the employees to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260454 B |
Issuance Date |
2018-07-09 |
Abatement Due Date |
2018-08-02 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-08-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: On or about January 12, 2018, at 120 NE 4th Street, The Whitney, (one20fourth), FORT LAUDERDALE, FL, 33301, employees were operating, assembling, dissembling and moving two-point suspended scaffolds without training by a Competent Person, so as to enable the employees to recognize any hazards associated with the work in question therefore exposing the employees to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2018-07-09 |
Abatement Due Date |
2018-08-02 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-08-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: On or about January 12, 2018, at the above addressed jobsite, employees were observed operating a suspension scaffold, for the purpose of applying stucco, paint and water proofing to all four exterior walls of a new high-rise apartment building, while wearing a PFAS, wherein the system was rigged such that during a fall, the employees may free fall more than 6 feet and/or the system was rigged such that the employee would have contacted the lower level; therefore exposing the employees to fall hazards. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260502 D20 |
Issuance Date |
2018-07-09 |
Abatement Due Date |
2018-08-02 |
Current Penalty |
249.0 |
Initial Penalty |
415.0 |
Final Order |
2018-08-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(20): The employer did not provide for prompt rescue of employees in the event of a fall or did not assure that employees were able to rescue themselves: On or about January 12, 2018, at the above addressed jobsite, employees were observed operating a suspension scaffold, for the purpose of applying stucco, paint and water proofing to all four exterior walls of a new high-rise apartment building, while wearing a PFAS, during which the employer did not provide for prompt rescue of employees in the event of a suspended-fall, nor did the employer assure that employees were able to rescue themselves in the event of a suspended-fall; therefore exposing the employees to fall hazards and post-fall injuries resulting from a fall. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
|