Search icon

CISNEROS PLASTERING LLC - Florida Company Profile

Company Details

Entity Name: CISNEROS PLASTERING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

CISNEROS PLASTERING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 14 May 2010 (15 years ago)
Date of dissolution: 27 Sep 2024 (7 months ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2024 (7 months ago)
Document Number: L10000052402
FEI/EIN Number 272572641

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 398 Watercrest Street, SEBASTIAN, FL, 32958, US
Mail Address: 398 Watercrest Street, SEBASTIAN, FL, 32958, US
ZIP code: 32958
County: Indian River
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CISNEROS OSCAR Chief Executive Officer 398 Watercrest Street, SEBASTIAN, FL, 32958
CISNEROS OSCAR Agent 398 Watercrest Street, SEBASTIAN, FL, 32958

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
REINSTATEMENT 2023-11-20 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -
REINSTATEMENT 2022-11-30 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2022-09-23 - -
REINSTATEMENT 2021-12-11 - -
REGISTERED AGENT NAME CHANGED 2021-12-11 CISNEROS, OSCAR -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
REGISTERED AGENT ADDRESS CHANGED 2020-02-08 398 Watercrest Street, SEBASTIAN, FL 32958 -
CHANGE OF PRINCIPAL ADDRESS 2020-02-08 398 Watercrest Street, SEBASTIAN, FL 32958 -

Documents

Name Date
REINSTATEMENT 2023-11-20
REINSTATEMENT 2022-11-30
REINSTATEMENT 2021-12-11
ANNUAL REPORT 2020-02-08
ANNUAL REPORT 2019-04-26
ANNUAL REPORT 2018-04-25
ANNUAL REPORT 2017-05-09
ANNUAL REPORT 2016-03-30
ANNUAL REPORT 2015-03-19
REINSTATEMENT 2014-01-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342223906 0418800 2017-04-04 979 FLAMEVINE LANE, VERO BEACH, FL, 32963
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-04-04
Emphasis L: FALL, P: FALL
Case Closed 2018-09-05

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2017-04-27
Abatement Due Date 2017-05-30
Current Penalty 1629.6
Initial Penalty 2716.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about April 4, 2017, at the above addressed site, employees were exposed to fall hazards of approximately 7 foot 6 inches and 20 feet when performing masonry work on a fabricated frame scaffold that did not have the work level platforms fully planked.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2017-04-27
Abatement Due Date 2017-05-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about April 4, 2017, at the above addressed site, employees were exposed to fall hazards of approximately 7 feet 6 inches and 20 feet when performing masonry work on a fabricated frame scaffold prior to being provided with training for the hazards associated with scaffolds.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2017-04-27
Abatement Due Date 2017-05-30
Current Penalty 1629.6
Initial Penalty 2716.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about April 4, 2017, at the above addressed site, employees were exposed to fall hazards of approximately 7 feet 6 inches and 20 feet when performing masonry work on a fabricated frame scaffold that did not have the frame legs bearing on baseplates and/or mudsills.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2017-04-27
Abatement Due Date 2017-05-30
Current Penalty 1629.6
Initial Penalty 2716.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about April 4, 2017, at the above addressed site, employees were exposed to fall hazards of approximately 7 feet 6 inches and 20 feet when gaining access to and from the work level platform of a fabricated frame scaffold to perform masonry work while not having a safe means of egress.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2017-04-27
Abatement Due Date 2017-05-30
Current Penalty 1629.6
Initial Penalty 2716.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about April 4, 2017, at the above addressed site, an employee was exposed to a fall hazard of approximately 20 feet when performing masonry work on a fabricated frame scaffold while not being protected from falling to the lower level.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2017-04-27
Abatement Due Date 2017-05-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about April 4, 2017, at the above addressed site, employees were exposed to fall hazards of approximately 7 feet 6 inches and 20 feet when performing masonry work on a fabricated frame scaffold that was not erected by a competent person in scaffold erection.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2017-04-27
Abatement Due Date 2017-05-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about April 4, 2017, at the above addressed site, employees were to the hazards associated with chemicals including but not limited to Gasoline and Rinker Stucco Cement where the employer did not develop, implement or maintain a hazard communication program.