342269917
|
0420600
|
2017-04-24
|
12901 STARKEY ROAD SUITE 1900, LARGO, FL, 33773
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-06-23
|
Case Closed |
2017-06-28
|
Related Activity
Type |
Complaint |
Activity Nr |
1204462 |
Health |
Yes |
|
|
342043767
|
0420600
|
2017-01-23
|
12901 STARKEY ROAD SUITE 1900, LARGO, FL, 33773
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-03-08
|
Case Closed |
2017-08-28
|
Related Activity
Type |
Complaint |
Activity Nr |
1171970 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2017-06-28 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
6338.0 |
Initial Penalty |
6338.0 |
Final Order |
2017-07-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Processing Room - 3M air-purifying respirators were required to be worn and no medical evaluations were conducted, on or about January 23, 2017. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2017-06-28 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Processing Room - 3M air-purifying respirators were required to be worn and no fit testing was conducted, on or about January 23, 2017. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 K01 |
Issuance Date |
2017-06-28 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(1): The employer did not provide respirator training that ensured that each employee could demonstrate knowledge of at least the following elements: Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator; What the limitations and capabilities of the respirator are; How to use the respirator effectively in emergency situations, including situations in which the respirator malfunctions; How to inspect, put on and remove, use, and check the seals of the respirator; What the procedures are for maintenance and storage of the respirator, and How to recognize medical signs and symptoms that may limit or prevent the effective use of respirators: (a) Processing Room - 3M air-purifying respirators were required to be worn and no training was conducted, on or about January 23, 2017. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19101048 L01 I |
Issuance Date |
2017-06-28 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
6338.0 |
Initial Penalty |
6338.0 |
Final Order |
2017-07-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1048(l)(1)(i): The employer did not institute medical surveillance programs for all employees exposed to formaldehyde at concentrations at or exceeding the action level or exceeding the STEL: (a) Processing Room - The employer did not institute medical surveillance programs for employees exposed to formaldehyde above the OSHA Permissible Exposure Level as documented in June 2016 and August 8, 2016 while working in the processing room. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19101048 N03 V |
Issuance Date |
2017-06-28 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-07-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1048(n)(3)(v): The training program for formaldehyde did not include instructions for the handling of spills, emergencies, and cleanup procedures: (a) Processing Room - Training on the procedures and methods for clean up and decontamination after a spill of formaldehyde were not conducted, on or about April 20, 2017. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101048 E01 I |
Issuance Date |
2017-06-28 |
Abatement Due Date |
2017-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-07-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1048(e)(1)(i): The employer did not establish regulated areas where the concentration of airborne formaldehyde exceeds either the TWA or the STEL and post all entrances and access ways with signs bearing the following legend: DANGER FORMALDEHYDE MAY CAUSE CANCER CAUSES SKIN, EYE, AND RESPIRATORY IRRITATION AUTHORIZED PERSONNEL ONLY (a) Processing Room - The employer posted the entrance with outdated verbiage, on or about April 20, 2017. |
|
|
341378198
|
0420600
|
2016-04-06
|
12901 STARKEY ROAD SUITE 1900, LARGO, FL, 33773
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-04-06
|
Case Closed |
2016-08-05
|
Related Activity
Type |
Complaint |
Activity Nr |
1067565 |
Health |
Yes |
|
|
340474659
|
0420600
|
2015-03-19
|
12901 STARKEY ROAD SUITE 1900, LARGO, FL, 33773
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-03-19
|
Emphasis |
L: FORMHYDE
|
Case Closed |
2015-05-21
|
Related Activity
Type |
Complaint |
Activity Nr |
968407 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101048 N02 |
Issuance Date |
2015-04-01 |
Abatement Due Date |
2015-04-27 |
Current Penalty |
3000.0 |
Initial Penalty |
3000.0 |
Final Order |
2015-04-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1048(n)(2): The employer did not provide employees with information and training on formaldehyde at the time of their initial assignment and/or wherever a new hazard from formaldehyde was introduced into their work area: a) Histology - An employee working at the facility for 2 months had not been trained, on or about March 19, 2015. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19101450 F01 |
Issuance Date |
2015-04-01 |
Abatement Due Date |
2015-04-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1450(f)(1): The employer did not provide laboratory employees with information and training to ensure that they were apprised of the hazards of chemicals present in their work area: a) Histology - An employee working at the facility for 2 months had not been trained on the hazards of chemicals including, but not limited to, xylene and alcohols, on or about March 19, 2015. |
|
|