Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-02-12
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2020-10-20
|
Related Activity
Type |
Referral |
Activity Nr |
1308529 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2018-02-14 |
Abatement Due Date |
2018-03-01 |
Current Penalty |
6468.0 |
Initial Penalty |
6468.0 |
Final Order |
2018-03-13 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a caught by hazard while working with a drill press (i.e. Jet, Model No. JDP-17MF) that lacked point of operation guarding. b. On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a caught by hazard while working with a drill press (i.e. Powermatic, Model No. 2000, Serial No. 020900019) that lacked point of operation guarding. c. On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a caught by hazard while working with a roll forming machine (i.e. aluminum panels, 24 gauge) that lacked a point of operation guard on its cutting area. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2018-02-14 |
Current Penalty |
3299.0 |
Initial Penalty |
3299.0 |
Final Order |
2018-03-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about February 12, 2018, at the manufacturing area of the above addressed worksite, employees were exposed to a struck by hazard while working with a drill press (i.e. Powermatic, Model No. 2000, Serial No. 020900019) that was not anchored. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100217 B04 I |
Issuance Date |
2018-02-14 |
Abatement Due Date |
2018-03-01 |
Current Penalty |
6468.0 |
Initial Penalty |
6468.0 |
Final Order |
2018-03-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: On or about February 12, 2018 at the manufacturing area of the above addressed worksite, an employee was exposed to a caught by hazard while working with a mechanical power press (i.e. Rouselle No. 3) whose pedal was not protected to prevent unintended operation. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100217 C02 I A |
Issuance Date |
2018-02-14 |
Abatement Due Date |
2018-03-01 |
Current Penalty |
6468.0 |
Initial Penalty |
6468.0 |
Final Order |
2018-03-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): On or about February 12, 2018 at the manufacturing area of the above addressed worksite, an employee was exposed to a caught by hazard while working with a mechanical power press (i.e. Rouselle No. 3) whose guard had openings at front, sides and over through which its point of operation could be accessed. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2018-02-14 |
Current Penalty |
3298.0 |
Initial Penalty |
3298.0 |
Final Order |
2018-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about February 12, 2018, at the manufacturing area the above addressed worksite, employees were exposed to a caught by hazard while working with a roll forming machine (i.e. aluminum panels, 24 gauge) which had sprocket wheels and chains which were not entirely enclosed. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2018-02-14 |
Abatement Due Date |
2018-02-22 |
Current Penalty |
5173.0 |
Initial Penalty |
5173.0 |
Final Order |
2018-03-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about February 12, 2018, at the manufacturing area, of the above addressed worksite, an electrical panelboard (i.e. GE Power Mark Plus Load Center) installed inside a cabinet had an unused opening which was not covered, exposing employees to an electrical hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100303 G02 I |
Issuance Date |
2018-02-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about February 12, 2018, at the manufacturing area of the above addressed worksite, a cabinet had energized electrical wires which were not guarded, exposing employees to an electrical fire hazard. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 II |
Issuance Date |
2018-02-14 |
Abatement Due Date |
2018-03-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: On or about February 12, 2018, at the manufacturing area of the above addressed worksite, an electrical cord for a pedal of a grommet machine (i.e. Edward Segal Inc. Model No. 926) had a splice covered with electrical tape, exposing an employee to an electrical fire hazard. |
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2017-08-15
|
Emphasis |
L: HINOISE, P: HINOISE
|
Case Closed |
2018-07-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
2018-02-08 |
Abatement Due Date |
2018-03-07 |
Current Penalty |
5432.4 |
Initial Penalty |
9054.0 |
Final Order |
2018-03-05 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: On or about January 30, 2018 at the above addressed job site, an employee performing manufacturing of metal storm shutters using a roller form machine was exposed to noise dose of 109.3% or an equivalent of 90.6 dBA which was capable of causing permanent hearing loss. Monitoring was performed for 440 minute sampling time and zero exposure for the remaining 40 minutes of the 8 hour shift. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2018-02-08 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-03-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about August 15, 2017, at the above addressed jobsite, employees were exposed to a struck by and air embolism hazards while performing cleaning of aluminum shavings using compressed air at 95 psi. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 L04 III |
Issuance Date |
2018-02-08 |
Abatement Due Date |
2018-03-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about August 15, 2017, at the above addressed jobsite, employees handling metal parts and metal shutters using Toyota lift trucks (Model 7FGGCU25 and Model 6FGCU25) were not evaluated every three years, exposing them to struck-by hazards. |
|
|