Entity Name: | BLOCKS 'R' US CONCRETE LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
BLOCKS 'R' US CONCRETE LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 13 Jul 2009 (16 years ago) |
Date of dissolution: | 29 Mar 2017 (8 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 29 Mar 2017 (8 years ago) |
Document Number: | L09000067393 |
FEI/EIN Number |
270532937
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1206 ESTER ST, GROVELAND, FL, 34736, US |
Mail Address: | 1206 ESTER ST, GROVELAND, FL, 34736, US |
ZIP code: | 34736 |
County: | Lake |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
LONG DONALD E | Manager | 1206 ESTHER ST, GROVELAND, FL, 34736 |
BUSINESS & TAX SERVICES BY LIZETTE INC | Agent | - |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2017-03-29 | - | - |
REGISTERED AGENT NAME CHANGED | 2012-04-24 | BUSINESS & TAX SERVICES BY LIZETTE, INC | - |
REGISTERED AGENT ADDRESS CHANGED | 2012-04-24 | 6845 S FORK RANCH DR, CLERMONT, FL 34714 | - |
CHANGE OF PRINCIPAL ADDRESS | 2010-02-26 | 1206 ESTER ST, GROVELAND, FL 34736 | - |
CHANGE OF MAILING ADDRESS | 2010-02-26 | 1206 ESTER ST, GROVELAND, FL 34736 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2017-01-25 |
ANNUAL REPORT | 2016-03-09 |
ANNUAL REPORT | 2015-03-18 |
ANNUAL REPORT | 2014-03-05 |
ANNUAL REPORT | 2013-04-06 |
ANNUAL REPORT | 2012-04-24 |
ANNUAL REPORT | 2011-04-26 |
ANNUAL REPORT | 2010-02-26 |
Florida Limited Liability | 2009-07-13 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341397396 | 0420600 | 2016-04-13 | 575PALMER AVE, WINTER PARK, FL, 32789 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2016-05-12 |
Abatement Due Date | 2016-05-18 |
Current Penalty | 1440.0 |
Initial Penalty | 2400.0 |
Final Order | 2016-06-06 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a. Scaffold south side - a ladder for access to the welded frame scaffold was not provided, in that, employees used end frames and railings for access and were exposed up to a 19 foot fall hazard. Violation observed on or about 4/13/16. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 F15 |
Issuance Date | 2016-05-12 |
Abatement Due Date | 2016-05-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-06-06 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees: without satisfying the criteria of subparagraphs (i) - (iv) of this paragraph: a. Scaffold south side - an A-frame ladder was used on the top scaffold platform to increase the working height and exposed employees to a 23 foot fall hazard. Violation observed on or about 4/13/16. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2016-05-12 |
Abatement Due Date | 2016-05-18 |
Current Penalty | 1440.0 |
Initial Penalty | 2400.0 |
Final Order | 2016-06-06 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. Scaffold south side - guardrails were not provided on the welded frame scaffold during stucco operations and exposed employees up to a 19 foot fall hazard. Violation observed on or about 4/13/16. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260454 A01 |
Issuance Date | 2016-05-12 |
Abatement Due Date | 2016-06-29 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-06-06 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area: a. Scaffold south side - employees who used a welded frame scaffold during masonry operations had not been trained in the safe use of the scaffold and the hazards associated with the use of the scaffold exposing employees to a 19 foot fall hazard. Violation observed on or about 4/13/16. |