Search icon

BLOCKS 'R' US CONCRETE LLC - Florida Company Profile

Company Details

Entity Name: BLOCKS 'R' US CONCRETE LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

BLOCKS 'R' US CONCRETE LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 13 Jul 2009 (16 years ago)
Date of dissolution: 29 Mar 2017 (8 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 29 Mar 2017 (8 years ago)
Document Number: L09000067393
FEI/EIN Number 270532937

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1206 ESTER ST, GROVELAND, FL, 34736, US
Mail Address: 1206 ESTER ST, GROVELAND, FL, 34736, US
ZIP code: 34736
County: Lake
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LONG DONALD E Manager 1206 ESTHER ST, GROVELAND, FL, 34736
BUSINESS & TAX SERVICES BY LIZETTE INC Agent -

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2017-03-29 - -
REGISTERED AGENT NAME CHANGED 2012-04-24 BUSINESS & TAX SERVICES BY LIZETTE, INC -
REGISTERED AGENT ADDRESS CHANGED 2012-04-24 6845 S FORK RANCH DR, CLERMONT, FL 34714 -
CHANGE OF PRINCIPAL ADDRESS 2010-02-26 1206 ESTER ST, GROVELAND, FL 34736 -
CHANGE OF MAILING ADDRESS 2010-02-26 1206 ESTER ST, GROVELAND, FL 34736 -

Documents

Name Date
ANNUAL REPORT 2017-01-25
ANNUAL REPORT 2016-03-09
ANNUAL REPORT 2015-03-18
ANNUAL REPORT 2014-03-05
ANNUAL REPORT 2013-04-06
ANNUAL REPORT 2012-04-24
ANNUAL REPORT 2011-04-26
ANNUAL REPORT 2010-02-26
Florida Limited Liability 2009-07-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341397396 0420600 2016-04-13 575PALMER AVE, WINTER PARK, FL, 32789
Inspection Type Prog Other
Scope Partial
Safety/Health Safety
Close Conference 2016-04-13
Emphasis L: FALL, P: FALL
Case Closed 2016-12-16

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-05-12
Abatement Due Date 2016-05-18
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2016-06-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a. Scaffold south side - a ladder for access to the welded frame scaffold was not provided, in that, employees used end frames and railings for access and were exposed up to a 19 foot fall hazard. Violation observed on or about 4/13/16.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F15
Issuance Date 2016-05-12
Abatement Due Date 2016-05-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-06
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees: without satisfying the criteria of subparagraphs (i) - (iv) of this paragraph: a. Scaffold south side - an A-frame ladder was used on the top scaffold platform to increase the working height and exposed employees to a 23 foot fall hazard. Violation observed on or about 4/13/16.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-05-12
Abatement Due Date 2016-05-18
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2016-06-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. Scaffold south side - guardrails were not provided on the welded frame scaffold during stucco operations and exposed employees up to a 19 foot fall hazard. Violation observed on or about 4/13/16.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260454 A01
Issuance Date 2016-05-12
Abatement Due Date 2016-06-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area: a. Scaffold south side - employees who used a welded frame scaffold during masonry operations had not been trained in the safe use of the scaffold and the hazards associated with the use of the scaffold exposing employees to a 19 foot fall hazard. Violation observed on or about 4/13/16.