345086979
|
0419700
|
2021-01-06
|
7827 ISLAND FOX ROD, JACKSONVILLE, FL, 32222
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-01-06
|
Emphasis |
L: FALL, P: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1508943 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2021-02-05 |
Current Penalty |
1200.0 |
Initial Penalty |
22527.0 |
Contest Date |
2021-06-15 |
Final Order |
2021-11-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels are not protected by guardrail systems, safety net system, or personal fall arrest system, nor are employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Employees performing roofing work are not protected from fall hazards by the use of a fall protection system. The employer fails to assure effective protections against falls as required by the standard, as demonstrated on January 6, 2021, when employees are sheathing a residential roof with a 6:12 pitch at 7827 Island Fox Road Jacksonville, Florida, and are exposed to a 10 feet 1 inch and higher fall hazard to the ground in that they are not attached to a personal fall protection system. Chris Sawdo Construction LLC. was previously cited for a willful violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1140057, citation number 01, item number 001 and was affirmed as a final order on September 29, 2016, with respect to a workplace located at 478 Heron Landing Road, Lot 166, Saint Johns, FL 32259. Chris Sawdo Construction LLC. was previously cited for a willful violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1132824, citation number 02, item number 001 and was affirmed as a final order on September 29, 2016, with respect to a workplace located at 548 Colorado Springs Way, Saint Augustine, FL 32092. |
|
|
341400570
|
0419700
|
2016-04-13
|
478 HERON LANDING ROAD LOT 166 - DURBIN CROSSING, SAINT JOHNS, FL, 32259
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-04-13
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2022-10-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Willful |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-09-01 |
Abatement Due Date |
2016-09-28 |
Current Penalty |
96026.0 |
Initial Penalty |
96026.0 |
Final Order |
2016-09-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. Employees installing sheathing at elevations of six feet or more above the ground are not being protected from fall hazards by a fall protection system: The employer fails to assure effective protection against falls are required by the standard, as demonstrated on April 13, 2016, when employees installing sheathing on a 6:12 pitch roof of a house located at 478 Heron Landing Road, in St. Johns Florida were exposed to a 20 feet 7 inch fall hazard above lower level in that they were not protected by a fall protection system. Chris Sawdo Construction, LLC was previously cited for a Willful violation with 11B language of this occupational safety and health standard, which was contained in OSHA inspection number 978000, citation number 2, item number 1 and was affirmed as a final order on October 22, 2014, with respect to a workplace located at 153 South Twin Maple Road in Saint Augustine Florida. Chris Sawdo Construction, LLC was previously cited for a Repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 879783 citation number 2, item number 1 and was affirmed as a final order on March 5, 2013, with respect to a workplace located at 4668Karsten Creek Drive Jacksonville Florida. Chris Sawdo Construction, LLC was previously cited for a Willful violation of this occupational safety and health standard, which was contained in OSHA inspection number 315479832, citation number 1, item number 1 and was affirmed as a final order on January 23, 2012, with respect to a workplace located at 11096 Lothmore Road Jacksonville Florida. |
|
|
341328243
|
0419700
|
2016-03-14
|
548 COLORADO SPRINGS WAY, SAINT AUGUSTINE, FL, 32092
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-03-14
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-08-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1132829 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2016-09-01 |
Current Penalty |
2352.0 |
Initial Penalty |
2352.0 |
Final Order |
2016-09-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder).: a. On or about March 14, 2016, at the right side of the house, the fiberglass extension ladder used for roof access was set up at a 57 degree angle with the horizontal distance set at 71 inches for a 131 inches of working length on the ladder, exposing employees to the hazard of a falling ladder. |
|
Citation ID |
02001 |
Citaton Type |
Willful |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-09-01 |
Abatement Due Date |
2016-09-21 |
Current Penalty |
96026.0 |
Initial Penalty |
96026.0 |
Final Order |
2016-09-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. Employees installing framing and sheathing at elevations of six feet or more above the ground are not being protected from fall hazards by a fall protection system: The employer fails to assure effective protection against falls as required by the standard, as demonstrated on March 14, 2016, when employees installing OSB board roof sheathing on the 6:12 pitch roof of a house at 548 Colorado Springs Way in Saint Augustine Florida were exposed to 9 to 18 feet fall hazards above lower levels in that they were not protected by a fall protection system. Chris Sawdo Construction, LLC was previously cited for a Willful violation of this occupational safety and health standard, which was contained in OSHA inspection number 978000, citation number 2, item number 1 and was affirmed as a final order on October 22, 2014, with respect to a workplace located at 153 South Twin Maple Road in Saint Augustine Florida. Chris Sawdo Construction, LLC was previously cited for a Repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 879783 citation number 2, item number 1 and was affirmed as a final order on March 5, 2013, with respect to a workplace located at 4668Karsten Creek Drive Jacksonville Florida. Chris Sawdo Construction, LLC was previously cited for a Willful violation of this occupational safety and health standard, which was contained in OSHA inspection number 315479832, citation number 1, item number 1 and was affirmed as a final order on January 23, 2012, with respect to a workplace located at 11096 Lothmore Road Jacksonville Florida. |
|
Citation ID |
03001 |
Citaton Type |
Repeat |
Standard Cited |
19261053 B01 |
Issuance Date |
2016-09-01 |
Abatement Due Date |
2016-09-21 |
Current Penalty |
4703.0 |
Initial Penalty |
4703.0 |
Final Order |
2016-09-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about March 14, 2016, on the right side of the house, the fiberglass extension ladder used for roof access extended only 26 inches above the edge of the roof eave, exposing employees to a 9 feet fall hazard. Chris Sawdo Construction, LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 978000, citation number 1, item number 2 and was affirmed as a final order on October 22, 2014, with respect to a workplace located at 153 South Twin Maple Rd in Saint Augustine, Florida. |
|
|
339780009
|
0419700
|
2014-05-23
|
153 S. TWIN MAPLE RD, SAINT AUGUSTINE, FL, 32084
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-05-23
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-16 |
Current Penalty |
880.0 |
Initial Penalty |
2200.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a. On or about May 23, 2014, on the back side of the house, employees descended from the top cords of trusses and the roof by climbing the interior framing of the structure, exposing themselves to a 14 feet fall hazard to a concrete slab. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-16 |
Current Penalty |
880.0 |
Initial Penalty |
2200.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: A. On or about May 23, 2014, the roof access ladder used by employees did not extend at least 36 inches above the edge of the eaves, exposing employees to a 9 feet fall hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-16 |
Current Penalty |
880.0 |
Initial Penalty |
2200.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects were not immediately marked "Defective, Do not Use" and withdrawn from service: a. On or about May 23, 2014, the aluminum extension ladder used by employees for roof access ladder that had dented and cracked rungs, dented and cracked rails, and corroded and loose rung lock bolts was not withdrawn from service. Employees accessing the roof with the damaged ladder were exposed to a maximum 9 feet fall hazard from ladder collapse. |
|
Citation ID |
02001 |
Citaton Type |
Willful |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-16 |
Current Penalty |
21560.0 |
Initial Penalty |
53900.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a. Employees working from elevation of 8 to 18 feet while installing roof sheathing are not being protected from the hazard of falling from these elevations to the concrete slabs. The employer has not installed fall protection systems, nor required the use of personal fall protection systems. This violation was most recently observed on or about May 23, 2014, at a job site located at 153 Twin Maple Rd, Saint Augustine Florida. On the roof sheathing and top cords of trusses, employees installing roof sheathing were exposed to an 8 to 18 feet fall hazard in that they were not protected by a fall protection system. To abate this violation, the employer must ensure that all employees working at elevations of 6 feet or greater are protected from falls by a fall protection system. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the steps it is taking to ensure compliance, including and explanation of how these steps protect its employees from fall hazards. |
|
|
338797830
|
0419700
|
2013-02-11
|
4668 KARSTEN CREEK DRIVE, JACKSONVILLE, FL, 32218
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-02-11
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2015-01-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2013-02-19 |
Current Penalty |
400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-03-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a. On or about February 11, 2013, employees did not have safe access and egress from the second floor to the first floor, exposing them to an 8 feet fall hazard. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-02-19 |
Current Penalty |
2000.0 |
Initial Penalty |
4400.0 |
Final Order |
2013-03-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
Chris Sawdo Construction, LLC was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection 313882425, Serious citation number 01, 002, issued on March 23, 2011, with respect to a workplace at 6089 Little Colt Court, Jacksonville, FL, with a Final Order date of May 3, 2011. 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about February 11, 2013, on the 5:12 pitch roof, employees installing OSB roofing material were not protected from a 10 feet fall hazard by the use of a fall protection system. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260050 D01 |
Issuance Date |
2013-02-19 |
Abatement Due Date |
2013-02-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-03-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required: a. On or about February 11, 2013, the employer did not provide employees with a first aid kit or supplies. |
|
|
315479832
|
0419700
|
2011-09-14
|
11096 LOTHMORE RD, JACKSONVILLE, FL, 32221
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-09-15
|
Emphasis |
L: FALL, S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT
|
Case Closed |
2012-01-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Willful |
Standard Cited |
19260501 B13 |
Issuance Date |
2011-10-25 |
Abatement Due Date |
2011-10-28 |
Current Penalty |
1500.0 |
Initial Penalty |
8800.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
313882425
|
0419700
|
2011-03-15
|
6089 LITTLE COLT COURT, JACKSONVILLE, FL, 32234
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-03-15
|
Emphasis |
S: STRUCK-BY, S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR, L: FALL
|
Case Closed |
2012-09-26
|
Related Activity
Type |
Complaint |
Activity Nr |
208248393 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2011-03-23 |
Abatement Due Date |
2011-03-28 |
Current Penalty |
250.0 |
Initial Penalty |
1530.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2011-03-23 |
Abatement Due Date |
2011-03-28 |
Current Penalty |
250.0 |
Initial Penalty |
2040.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
05 |
|
|
308431378
|
0419700
|
2005-06-07
|
LOT 273 - CANNON POINT, ORANGE PARK, FL, 32073
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-06-07
|
Emphasis |
L: FALL
|
Case Closed |
2006-06-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260100 A |
Issuance Date |
2005-06-09 |
Abatement Due Date |
2005-06-14 |
Current Penalty |
500.0 |
Initial Penalty |
1200.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19260102 A01 |
Issuance Date |
2005-06-09 |
Abatement Due Date |
2005-06-14 |
Current Penalty |
500.0 |
Initial Penalty |
1200.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2005-06-09 |
Abatement Due Date |
2005-06-14 |
Current Penalty |
900.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Repeat |
Standard Cited |
19261051 A |
Issuance Date |
2005-06-09 |
Abatement Due Date |
2005-06-14 |
Current Penalty |
500.0 |
Initial Penalty |
1200.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
|
306748922
|
0419700
|
2004-02-03
|
12351 TROPIC DRIVE, JACKSONVILLE, FL, 32225
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2004-02-03
|
Emphasis |
L: FALL
|
Case Closed |
2005-02-25
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2004-03-03 |
Abatement Due Date |
2004-03-11 |
Current Penalty |
202.5 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2004-03-03 |
Abatement Due Date |
2004-03-11 |
Current Penalty |
202.5 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2004-03-03 |
Abatement Due Date |
2004-03-15 |
Current Penalty |
270.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2004-03-03 |
Abatement Due Date |
2004-03-11 |
Current Penalty |
202.5 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260020 B01 |
Issuance Date |
2004-03-03 |
Abatement Due Date |
2004-03-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
|