Search icon

CHRIS SAWDO CONSTRUCTION, LLC - Florida Company Profile

Company Details

Entity Name: CHRIS SAWDO CONSTRUCTION, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

CHRIS SAWDO CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 24 Apr 2009 (16 years ago)
Document Number: L09000039904
FEI/EIN Number 264758120

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1208 FOXMEADOW TRAIL, MIDDLEBURG, FL, 32068
Mail Address: 1208 FOXMEADOW TRAIL, MIDDLEBURG, FL, 32068
ZIP code: 32068
County: Clay
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SAWDO CHRIS L Managing Member 1208 FOXMEADOW TRAIL, MIDDLEBURG, FL, 32068
SAWDO CHRIS L Agent 1208 FOXMEADOW TRAIL, MIDDLEBURG, FL, 32068

Documents

Name Date
ANNUAL REPORT 2024-01-22
ANNUAL REPORT 2023-01-24
ANNUAL REPORT 2022-01-24
ANNUAL REPORT 2021-01-11
ANNUAL REPORT 2020-01-21
ANNUAL REPORT 2019-02-09
ANNUAL REPORT 2018-01-15
ANNUAL REPORT 2017-02-11
ANNUAL REPORT 2016-02-04
ANNUAL REPORT 2015-03-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345086979 0419700 2021-01-06 7827 ISLAND FOX ROD, JACKSONVILLE, FL, 32222
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2021-01-06
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1508943
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2021-02-05
Current Penalty 1200.0
Initial Penalty 22527.0
Contest Date 2021-06-15
Final Order 2021-11-19
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels are not protected by guardrail systems, safety net system, or personal fall arrest system, nor are employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Employees performing roofing work are not protected from fall hazards by the use of a fall protection system. The employer fails to assure effective protections against falls as required by the standard, as demonstrated on January 6, 2021, when employees are sheathing a residential roof with a 6:12 pitch at 7827 Island Fox Road Jacksonville, Florida, and are exposed to a 10 feet 1 inch and higher fall hazard to the ground in that they are not attached to a personal fall protection system. Chris Sawdo Construction LLC. was previously cited for a willful violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1140057, citation number 01, item number 001 and was affirmed as a final order on September 29, 2016, with respect to a workplace located at 478 Heron Landing Road, Lot 166, Saint Johns, FL 32259. Chris Sawdo Construction LLC. was previously cited for a willful violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1132824, citation number 02, item number 001 and was affirmed as a final order on September 29, 2016, with respect to a workplace located at 548 Colorado Springs Way, Saint Augustine, FL 32092.
341400570 0419700 2016-04-13 478 HERON LANDING ROAD LOT 166 - DURBIN CROSSING, SAINT JOHNS, FL, 32259
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-04-13
Emphasis L: FALL, P: FALL
Case Closed 2022-10-05

Violation Items

Citation ID 01001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2016-09-01
Abatement Due Date 2016-09-28
Current Penalty 96026.0
Initial Penalty 96026.0
Final Order 2016-09-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. Employees installing sheathing at elevations of six feet or more above the ground are not being protected from fall hazards by a fall protection system: The employer fails to assure effective protection against falls are required by the standard, as demonstrated on April 13, 2016, when employees installing sheathing on a 6:12 pitch roof of a house located at 478 Heron Landing Road, in St. Johns Florida were exposed to a 20 feet 7 inch fall hazard above lower level in that they were not protected by a fall protection system. Chris Sawdo Construction, LLC was previously cited for a Willful violation with 11B language of this occupational safety and health standard, which was contained in OSHA inspection number 978000, citation number 2, item number 1 and was affirmed as a final order on October 22, 2014, with respect to a workplace located at 153 South Twin Maple Road in Saint Augustine Florida. Chris Sawdo Construction, LLC was previously cited for a Repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 879783 citation number 2, item number 1 and was affirmed as a final order on March 5, 2013, with respect to a workplace located at 4668Karsten Creek Drive Jacksonville Florida. Chris Sawdo Construction, LLC was previously cited for a Willful violation of this occupational safety and health standard, which was contained in OSHA inspection number 315479832, citation number 1, item number 1 and was affirmed as a final order on January 23, 2012, with respect to a workplace located at 11096 Lothmore Road Jacksonville Florida.
341328243 0419700 2016-03-14 548 COLORADO SPRINGS WAY, SAINT AUGUSTINE, FL, 32092
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-03-14
Emphasis L: FALL, P: FALL
Case Closed 2023-08-09

Related Activity

Type Inspection
Activity Nr 1132829
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2016-09-01
Current Penalty 2352.0
Initial Penalty 2352.0
Final Order 2016-09-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder).: a. On or about March 14, 2016, at the right side of the house, the fiberglass extension ladder used for roof access was set up at a 57 degree angle with the horizontal distance set at 71 inches for a 131 inches of working length on the ladder, exposing employees to the hazard of a falling ladder.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2016-09-01
Abatement Due Date 2016-09-21
Current Penalty 96026.0
Initial Penalty 96026.0
Final Order 2016-09-29
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. Employees installing framing and sheathing at elevations of six feet or more above the ground are not being protected from fall hazards by a fall protection system: The employer fails to assure effective protection against falls as required by the standard, as demonstrated on March 14, 2016, when employees installing OSB board roof sheathing on the 6:12 pitch roof of a house at 548 Colorado Springs Way in Saint Augustine Florida were exposed to 9 to 18 feet fall hazards above lower levels in that they were not protected by a fall protection system. Chris Sawdo Construction, LLC was previously cited for a Willful violation of this occupational safety and health standard, which was contained in OSHA inspection number 978000, citation number 2, item number 1 and was affirmed as a final order on October 22, 2014, with respect to a workplace located at 153 South Twin Maple Road in Saint Augustine Florida. Chris Sawdo Construction, LLC was previously cited for a Repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 879783 citation number 2, item number 1 and was affirmed as a final order on March 5, 2013, with respect to a workplace located at 4668Karsten Creek Drive Jacksonville Florida. Chris Sawdo Construction, LLC was previously cited for a Willful violation of this occupational safety and health standard, which was contained in OSHA inspection number 315479832, citation number 1, item number 1 and was affirmed as a final order on January 23, 2012, with respect to a workplace located at 11096 Lothmore Road Jacksonville Florida.
Citation ID 03001
Citaton Type Repeat
Standard Cited 19261053 B01
Issuance Date 2016-09-01
Abatement Due Date 2016-09-21
Current Penalty 4703.0
Initial Penalty 4703.0
Final Order 2016-09-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about March 14, 2016, on the right side of the house, the fiberglass extension ladder used for roof access extended only 26 inches above the edge of the roof eave, exposing employees to a 9 feet fall hazard. Chris Sawdo Construction, LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 978000, citation number 1, item number 2 and was affirmed as a final order on October 22, 2014, with respect to a workplace located at 153 South Twin Maple Rd in Saint Augustine, Florida.
339780009 0419700 2014-05-23 153 S. TWIN MAPLE RD, SAINT AUGUSTINE, FL, 32084
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-05-23
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2014-09-26
Abatement Due Date 2014-10-16
Current Penalty 880.0
Initial Penalty 2200.0
Final Order 2014-10-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a. On or about May 23, 2014, on the back side of the house, employees descended from the top cords of trusses and the roof by climbing the interior framing of the structure, exposing themselves to a 14 feet fall hazard to a concrete slab.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-09-26
Abatement Due Date 2014-10-16
Current Penalty 880.0
Initial Penalty 2200.0
Final Order 2014-10-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: A. On or about May 23, 2014, the roof access ladder used by employees did not extend at least 36 inches above the edge of the eaves, exposing employees to a 9 feet fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B16
Issuance Date 2014-09-26
Abatement Due Date 2014-10-16
Current Penalty 880.0
Initial Penalty 2200.0
Final Order 2014-10-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(16): Portable ladders with structural defects were not immediately marked "Defective, Do not Use" and withdrawn from service: a. On or about May 23, 2014, the aluminum extension ladder used by employees for roof access ladder that had dented and cracked rungs, dented and cracked rails, and corroded and loose rung lock bolts was not withdrawn from service. Employees accessing the roof with the damaged ladder were exposed to a maximum 9 feet fall hazard from ladder collapse.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2014-09-26
Abatement Due Date 2014-10-16
Current Penalty 21560.0
Initial Penalty 53900.0
Final Order 2014-10-22
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a. Employees working from elevation of 8 to 18 feet while installing roof sheathing are not being protected from the hazard of falling from these elevations to the concrete slabs. The employer has not installed fall protection systems, nor required the use of personal fall protection systems. This violation was most recently observed on or about May 23, 2014, at a job site located at 153 Twin Maple Rd, Saint Augustine Florida. On the roof sheathing and top cords of trusses, employees installing roof sheathing were exposed to an 8 to 18 feet fall hazard in that they were not protected by a fall protection system. To abate this violation, the employer must ensure that all employees working at elevations of 6 feet or greater are protected from falls by a fall protection system. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the steps it is taking to ensure compliance, including and explanation of how these steps protect its employees from fall hazards.
338797830 0419700 2013-02-11 4668 KARSTEN CREEK DRIVE, JACKSONVILLE, FL, 32218
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-02-11
Emphasis P: FALL, L: FALL
Case Closed 2015-01-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2013-02-19
Current Penalty 400.0
Initial Penalty 2000.0
Final Order 2013-03-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a. On or about February 11, 2013, employees did not have safe access and egress from the second floor to the first floor, exposing them to an 8 feet fall hazard.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2013-02-19
Current Penalty 2000.0
Initial Penalty 4400.0
Final Order 2013-03-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line Chris Sawdo Construction, LLC was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection 313882425, Serious citation number 01, 002, issued on March 23, 2011, with respect to a workplace at 6089 Little Colt Court, Jacksonville, FL, with a Final Order date of May 3, 2011. 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about February 11, 2013, on the 5:12 pitch roof, employees installing OSB roofing material were not protected from a 10 feet fall hazard by the use of a fall protection system.
Citation ID 03001
Citaton Type Other
Standard Cited 19260050 D01
Issuance Date 2013-02-19
Abatement Due Date 2013-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-05
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required: a. On or about February 11, 2013, the employer did not provide employees with a first aid kit or supplies.
315479832 0419700 2011-09-14 11096 LOTHMORE RD, JACKSONVILLE, FL, 32221
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2011-09-15
Emphasis L: FALL, S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT
Case Closed 2012-01-30

Violation Items

Citation ID 01001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2011-10-25
Abatement Due Date 2011-10-28
Current Penalty 1500.0
Initial Penalty 8800.0
Nr Instances 1
Nr Exposed 2
Gravity 01
313882425 0419700 2011-03-15 6089 LITTLE COLT COURT, JACKSONVILLE, FL, 32234
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2011-03-15
Emphasis S: STRUCK-BY, S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR, L: FALL
Case Closed 2012-09-26

Related Activity

Type Complaint
Activity Nr 208248393
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2011-03-23
Abatement Due Date 2011-03-28
Current Penalty 250.0
Initial Penalty 1530.0
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2011-03-23
Abatement Due Date 2011-03-28
Current Penalty 250.0
Initial Penalty 2040.0
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 05
308431378 0419700 2005-06-07 LOT 273 - CANNON POINT, ORANGE PARK, FL, 32073
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2005-06-07
Emphasis L: FALL
Case Closed 2006-06-13

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260100 A
Issuance Date 2005-06-09
Abatement Due Date 2005-06-14
Current Penalty 500.0
Initial Penalty 1200.0
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2005-06-09
Abatement Due Date 2005-06-14
Current Penalty 500.0
Initial Penalty 1200.0
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01003
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2005-06-09
Abatement Due Date 2005-06-14
Current Penalty 900.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 3
Gravity 03
Citation ID 01004
Citaton Type Repeat
Standard Cited 19261051 A
Issuance Date 2005-06-09
Abatement Due Date 2005-06-14
Current Penalty 500.0
Initial Penalty 1200.0
Nr Instances 1
Nr Exposed 4
Gravity 01
306748922 0419700 2004-02-03 12351 TROPIC DRIVE, JACKSONVILLE, FL, 32225
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2004-02-03
Emphasis L: FALL
Case Closed 2005-02-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2004-03-03
Abatement Due Date 2004-03-11
Current Penalty 202.5
Initial Penalty 450.0
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2004-03-03
Abatement Due Date 2004-03-11
Current Penalty 202.5
Initial Penalty 450.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2004-03-03
Abatement Due Date 2004-03-15
Current Penalty 270.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 3
Gravity 02
Citation ID 01004
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2004-03-03
Abatement Due Date 2004-03-11
Current Penalty 202.5
Initial Penalty 450.0
Nr Instances 1
Nr Exposed 3
Gravity 01
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2004-03-03
Abatement Due Date 2004-03-29
Nr Instances 1
Nr Exposed 4
Gravity 01

Date of last update: 02 May 2025