Entity Name: | TUUCI, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
TUUCI, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 14 Nov 2008 (16 years ago) |
Last Event: | LC AMENDMENT |
Event Date Filed: | 27 Jun 2023 (2 years ago) |
Document Number: | L08000106238 |
FEI/EIN Number |
371575679
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1000 SE 8TH STREET, HIALEAH, FL, 33010, US |
Mail Address: | 1000 SE 8TH STREET, HIALEAH, FL, 33010, US |
ZIP code: | 33010 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
LEI number | Registered As | Jurisdiction Of Formation | General Category | Entity Status | Entity created at | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
549300P9QE2EMBTW3Y79 | L08000106238 | US-FL | GENERAL | ACTIVE | 2008-11-14 | |||||||||||||||||||
|
Legal | C/O CLARKE, DOUGAN, 1000 SE 8TH STREET, HIALEAH, US-FL, US, 33010 |
Headquarters | C/O Free, John, 1000 SE 8TH STREET, HIALEAH, US-FL, US, 33010 |
Registration details
Registration Date | 2015-01-23 |
Last Update | 2023-11-01 |
Status | LAPSED |
Next Renewal | 2023-10-31 |
LEI Issuer | 5493001KJTIIGC8Y1R12 |
Corroboration Level | FULLY_CORROBORATED |
Data Validated As | L08000106238 |
Name | Role | Address |
---|---|---|
NORTHWEST REGISTERED AGENT LLC | Agent | - |
TUUCI WORLDWIDE, LLC | Managing Member | - |
CLARKE DOUGAN H | Chief Executive Officer | 1000 SE 8TH STREET, HIALEAH, FL, 33010 |
SCHUTTE DAVID | Officer | 1000 SE 8TH ST, HIALEAH, FL, 33010 |
FREE JOHN | Officer | 1000 SE 8TH STREET, HIALEAH, FL, 33010 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
LC AMENDMENT | 2023-06-27 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-04-04 | 7901 4 ST N STE 300, ST PETERSBURG, FL 33702 | - |
LC STMNT OF RA/RO CHG | 2023-04-04 | - | - |
REGISTERED AGENT NAME CHANGED | 2023-04-04 | NORTHWEST REGISTERED AGENT LLC | - |
LC STMNT OF RA/RO CHG | 2021-11-18 | - | - |
LC AMENDMENT | 2021-11-18 | - | - |
LC AMENDMENT | 2021-05-10 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2018-11-19 | 1000 SE 8TH STREET, HIALEAH, FL 33010 | - |
CHANGE OF MAILING ADDRESS | 2018-11-19 | 1000 SE 8TH STREET, HIALEAH, FL 33010 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-06 |
ANNUAL REPORT | 2024-02-06 |
LC Amendment | 2023-06-27 |
CORLCRACHG | 2023-04-04 |
ANNUAL REPORT | 2023-01-19 |
ANNUAL REPORT | 2022-01-03 |
LC Amendment | 2021-11-18 |
CORLCRACHG | 2021-11-18 |
LC Amendment | 2021-05-10 |
ANNUAL REPORT | 2021-01-04 |
Contract Type | Award or IDV Flag | PIID | Start Date | Current End Date | Potential End Date | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PURCHASE ORDER | AWARD | 191N6024P0521 | 2024-09-16 | 2025-02-27 | 2025-02-28 | |||||||||||||||||||||||||
|
Obligated Amount | 10415.00 |
Current Award Amount | 10415.00 |
Potential Award Amount | 10415.00 |
Description
Title | SUPPLY OF UMBRELLAS |
NAICS Code | 337127: INSTITUTIONAL FURNITURE MANUFACTURING |
Product and Service Codes | 7290: MISCELLANEOUS HOUSEHOLD AND COMMERCIAL FURNISHINGS AND APPLIANCES |
Recipient Details
Recipient | TUUCI, LLC |
UEI | YJXKHS5J2WN4 |
Recipient Address | UNITED STATES, 1000 SE 8TH ST, HIALEAH, MIAMI-DADE, FLORIDA, 330105780 |
Unique Award Key | CONT_AWD_19AQMM24P0866_1900_-NONE-_-NONE- |
Awarding Agency | Department of State |
Link | View Page |
Award Amounts
Obligated Amount | 39510.50 |
Current Award Amount | 39510.50 |
Potential Award Amount | 39510.50 |
Description
Title | FURNITURE. |
NAICS Code | 337127: INSTITUTIONAL FURNITURE MANUFACTURING |
Product and Service Codes | 7110: OFFICE FURNITURE |
Recipient Details
Recipient | TUUCI, LLC |
UEI | YJXKHS5J2WN4 |
Recipient Address | UNITED STATES, 1000 SE 8TH ST, HIALEAH, MIAMI-DADE, FLORIDA, 330105780 |
Unique Award Key | CONT_AWD_19AQMM21P1113_1900_-NONE-_-NONE- |
Awarding Agency | Department of State |
Link | View Page |
Award Amounts
Obligated Amount | 11340.00 |
Current Award Amount | 11680.00 |
Potential Award Amount | 11680.00 |
Description
Title | FURNITURE |
NAICS Code | 337214: OFFICE FURNITURE (EXCEPT WOOD) MANUFACTURING |
Product and Service Codes | 7110: OFFICE FURNITURE |
Recipient Details
Recipient | TUUCI, LLC |
UEI | YJXKHS5J2WN4 |
Recipient Address | UNITED STATES, 1000 SE 8TH ST, MIAMI, MIAMI-DADE, FLORIDA, 330105780 |
Unique Award Key | CONT_AWD_SAQMMA12M1193_1900_-NONE-_-NONE- |
Awarding Agency | Department of State |
Link | View Page |
Description
Title | THESE HOUSEHOLD ITEMS ARE FOR THE US EMBASSY IN THE COUNTRY AND/OR CITY OF: MONTEVIDEO |
NAICS Code | 337122: NONUPHOLSTERED WOOD HOUSEHOLD FURNITURE MANUFACTURING |
Product and Service Codes | 7105: HOUSEHOLD FURNITURE |
Recipient Details
Recipient | TUUCI, LLC |
UEI | YJXKHS5J2WN4 |
Legacy DUNS | 964967090 |
Recipient Address | 2900 NORTHWEST 35TH STREET, MIAMI, 331425240, UNITED STATES |
FAIN | Awarding Agency | Assistance Listings | Start Date | End Date | Description | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
09517514ST1001 | Export-Import Bank of the United States | 31.007 - EXPORT - LOAN GUARANTEE/INSURED LOANS | 2011-10-01 | 2012-10-01 | EXPORT INSURANCE COVERED PRODUCTS: METAL HOUSEHOLD FURNITURE MANUFACTURING | |||||||||||||||||||||
|
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346863590 | 0418800 | 2023-07-26 | 1000 SE 8 ST, HIALEAH, FL, 33010 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2054379 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1686559 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100184 C01 |
Issuance Date | 2023-09-01 |
Current Penalty | 4017.6 |
Initial Penalty | 6696.0 |
Final Order | 2023-09-21 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.184(c)(1): Sling(s) that were damaged or defective were used: On or about August 9, 2023, at 1000 SE 8th St, Hialeah, FL 33010, employer did not ensure slings were not defective or damaged, exposing employees to crush by hazards while pulling load with damaged sling. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100217 C02 I A |
Issuance Date | 2023-09-01 |
Abatement Due Date | 2023-09-28 |
Current Penalty | 4017.6 |
Initial Penalty | 6696.0 |
Final Order | 2023-09-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): On or about July 26, 2023, at 1000 SE 8th St, Hialeah, FL 33010, the employer did not ensure hands or fingers could not enter into the OTMT Gear Drive Mill/Drill Machine point of operation by reaching around the guard, exposing employees to amputation hazards. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100252 A02 XIII C |
Issuance Date | 2023-09-01 |
Current Penalty | 4017.6 |
Initial Penalty | 6696.0 |
Final Order | 2023-09-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.252(a)(2)(xiii)(C): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment, and did not insist that cutters or welders and their supervisors were suitably trained in the safe operation of their equipment: On or about August 9, 2023, at 1000 SE 8th St, Hialeah, FL 33010, employer did not ensure welders were efficiently trained in the safe operation of their equipment, exposing employees to electrocution and burn hazards. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100253 B04 III |
Issuance Date | 2023-09-01 |
Current Penalty | 4017.6 |
Initial Penalty | 6696.0 |
Final Order | 2023-09-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: On or about July 26, 2023, at 1000 SE 8th St, Hialeah, FL 33010, employer did not ensure oxygen cylinder were stored a minimum distance of 20 Feet from acetylene cylinder, exposing employees to injuries related fire hazards. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19100254 D09 III |
Issuance Date | 2023-09-01 |
Current Penalty | 4017.6 |
Initial Penalty | 6696.0 |
Final Order | 2023-09-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace: On or about August 8, 2023, at 1000 SE 8th St, Hialeah, FL 33010, the employer did not ensure a welding ground cable with damaged insulation and exposed bare conductors were replaced therefore, exposing employees to injuries related to electrical shock hazard. |
Citation ID | 01006 |
Citaton Type | Serious |
Standard Cited | 19100334 A02 II |
Issuance Date | 2023-09-01 |
Current Penalty | 4017.6 |
Initial Penalty | 6696.0 |
Final Order | 2023-09-21 |
Nr Instances | 2 |
Nr Exposed | 8 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: a) On or about August 8, 2023, at 1000 SE 8th St, Hialeah, FL 33010, the employer did not remove from service the GNB GTCIII8-750T1 Industrial Battery Charger where the outer Insulated portion was damaged with exposed wiring; therefore, exposing employees to injuries related to electrical shock hazard. b) On or about August 8, 2023, at 1000 SE 8th St, Hialeah, FL 33010, the employer did not remove from service the Applied Energy Solution 24R0750E3D Industrial Battery Charger where the outer Insulated portion was damaged therefore, exposing employees to injuries related to electrical shock hazard. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2023-07-26 |
Emphasis | N: HEATNEP |
Case Closed | 2023-10-05 |
Related Activity
Type | Complaint |
Activity Nr | 2054379 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1686359 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100132 A |
Issuance Date | 2023-09-01 |
Current Penalty | 5357.4 |
Initial Penalty | 8929.0 |
Final Order | 2023-09-21 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) On or about 07/26/2023 at 1000 SE 8th St, Hialeah, FL 33010, the employer did not ensure that employees use appropriate eye protection while performing quality control testing of Tank 1 containing Bulk Kleen 690RT a corrosive (with a pH of < 1) and Tank 3 containing E-CLPS 2100HD a corrosive (with a pH of pH 2.1) in the wash area. b) On or about 07/26/2023 at 1000 SE 8th St, Hialeah, FL 33010, the employer did not ensure that Black Stallion GM 1611 welding gloves were maintained in a reliable condition for employees performing welding operations. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19101450 E01 |
Issuance Date | 2023-09-01 |
Abatement Due Date | 2023-09-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-09-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1450(e)(1): Where hazardous chemicals were used in the workplace, the employer did not develop and carry out the provisions of a written Chemical Hygiene Plan which was capable of protecting employees from health hazards associated with hazardous chemicals: On or about 07/26/2023 at 1000 SE 8th St, Hialeah, FL 33010, the employer did not develop and carry out the provisions of a written Chemical Hygiene Plan which was capable of protecting employees from health hazards associated with hazardous chemicals including, but not limited to, Bulk Kleen 690RT a corrosive (with a pH < 1) and E-CLPS 2100HD a corrosive (with a pH 2.1), for employees performing quality control of wash tanks. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2012-10-04 |
Case Closed | 2013-02-14 |
Related Activity
Type | Inspection |
Activity Nr | 579318 |
Safety | Yes |
Type | Referral |
Activity Nr | 594211 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100095 C01 |
Issuance Date | 2012-10-12 |
Abatement Due Date | 2013-02-11 |
Current Penalty | 3780.0 |
Initial Penalty | 6300.0 |
Final Order | 2012-11-07 |
Nr Instances | 1 |
Nr Exposed | 10 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: On or about 10/4/12, at the Tuuci LLC. frame department, two frame cutting and assembly workers were exposed to continuos noise levels of 87.7 dBa (73% dose) and 86.9 dBa (66% dose) respectively during the 420 minutes sampling period. Zero exposure was assumed for the unsampled period of time (90 minutes). |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2012-08-10 |
Emphasis | L: FORKLIFT |
Case Closed | 2012-11-05 |
Related Activity
Type | Inspection |
Activity Nr | 667561 |
Health | Yes |
Type | Complaint |
Activity Nr | 485790 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100136 A |
Issuance Date | 2012-10-09 |
Current Penalty | 2524.0 |
Initial Penalty | 4590.0 |
Final Order | 2012-11-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.136(a): General requirements. The employer shall ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet are exposed to electrical hazards. On or about 08/04/2012, an employee who was not wearing protective foot wear was exposed to struck by / crushing hazards while pushing a forklift whose wheel ran over the foot of the employee at facility located at 2900 NW 35th Street, Miami FL. 33142. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100178 M05 I |
Issuance Date | 2012-10-09 |
Current Penalty | 2103.0 |
Initial Penalty | 3825.0 |
Final Order | 2012-11-01 |
Nr Exposed | 12 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means shall be fully lowered, controls shall be neutralized, power shall be shut off, and brakes set. Wheels shall be blocked if the truck is parked on an incline. On or about 08/10/2012, employees were exposed to struck by hazards while operating and working in proximity to a powered industrial truck that was left unattended with brake not set at facility located at 2900 NW 35th Street, Miami FL. 33142. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2012-10-09 |
Current Penalty | 2103.0 |
Initial Penalty | 3825.0 |
Final Order | 2012-11-01 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. On or about 08/10/2012, employees were exposed to struck and cut by hazards while operating a miter saw that had a defective guard that did not retract, while cutting fiberglass parts at facility located at 2900 NW 35th Street, Miami FL. 33142. |
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2064126 | Intrastate Non-Hazmat | 2020-07-30 | 212945 | 2020 | 1 | 1 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 1 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 1 |
Vehicle Maintenance BASIC Roadside Performance measure value | 11 |
Total Number of Vehicle Inspections for the measurement period | 1 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 1 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Inspections
Unique report number of the inspection | 3195008027 |
State abbreviation that indicates the state the inspector is from | FL |
The date of the inspection | 2024-01-24 |
ID that indicates the level of inspection | Walk-around |
State abbreviation that indicates where the inspection occurred | FL |
Time weight of the inspection | 2 |
Number of Out-Of-Service violations related to Driver | 0 |
Number of Out-Of-Service violations related to vehicle | 0 |
Number of violations related to Hazardous Materials | 0 |
Total number of Out-Of-Service violations | 0 |
Total number of Out-Of-Service violations related to Hazardous Materials | 0 |
Description of the type of the main unit | STRAIGHT TRUCK |
Description of the make of the main unit | INTERNATIO |
License plate of the main unit | HZWM06 |
License state of the main unit | FL |
Vehicle Identification Number of the main unit | 1HTMKAAL4BH330306 |
Unsafe Driving BASIC inspection | Y |
Hours-of-Service Compliance BASIC inspection | Y |
Driver Fitness BASIC inspection | Y |
Controlled Substances/Alcohol BASIC inspection | Y |
Vehicle Maintenance BASIC inspection | Y |
Total number of BASIC violations | 4 |
Number of Unsafe Driving BASIC violations | 0 |
Number of Hours-of-Service Compliance BASIC violations | 0 |
Number of Driver Fitness BASIC violations | 0 |
Number of Controlled Substances/Alcohol BASIC violations | 0 |
Number of Vehicle Maintenance BASIC violations | 4 |
Number of Hazardous Materials Compliance BASIC violations | 0 |
Violations
The date of the inspection | 2024-01-24 |
Code of the violation | 3939ALSML |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 2 |
The time weight that is assigned to a violation | 2 |
The description of a violation | Lighting - Side marker lamp(s) inoperative |
The description of the violation group | Clearance Identification Lamps/Other |
The unit a violation is cited against | Vehicle main unit |
The date of the inspection | 2024-01-24 |
Code of the violation | 3939ALHLI |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 6 |
The time weight that is assigned to a violation | 2 |
The description of a violation | Lighting - Headlamp(s) - Any inoperative |
The description of the violation group | Lighting |
The unit a violation is cited against | Vehicle main unit |
The date of the inspection | 2024-01-24 |
Code of the violation | 39378AWS |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 1 |
The time weight that is assigned to a violation | 2 |
The description of a violation | Washers - Inoperative washing system. |
The description of the violation group | Windshield/ Glass/ Markings |
The unit a violation is cited against | Vehicle main unit |
The date of the inspection | 2024-01-24 |
Code of the violation | 39311A1LSML |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 2 |
The time weight that is assigned to a violation | 2 |
The description of a violation | Lighting - Side marker lamp(s) missing |
The description of the violation group | Clearance Identification Lamps/Other |
The unit a violation is cited against | Vehicle main unit |
Date of last update: 02 Apr 2025