Search icon

G&T CONTRACTOR SERVICES, LLC - Florida Company Profile

Company Details

Entity Name: G&T CONTRACTOR SERVICES, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

G&T CONTRACTOR SERVICES, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 26 Aug 2008 (17 years ago)
Last Event: LC AMENDMENT
Event Date Filed: 23 Jul 2020 (5 years ago)
Document Number: L08000081222
FEI/EIN Number 263237902

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 8480 MANRESA AVENUE, JACKSONVILLE, FL, 32244, US
Mail Address: 8480 MANRESA AVENUE, JACKSONVILLE, FL, 32244, US
ZIP code: 32244
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LEMERAND GARY Manager 8480 MANRESA AVENUE, JACKSONVILLE, FL, 32244
LEMERAND GARY Agent 8480 MANRESA AVENUE, JACKSONVILLE, FL, 32244

Events

Event Type Filed Date Value Description
LC AMENDMENT 2020-07-23 - -
REGISTERED AGENT NAME CHANGED 2019-03-28 LEMERAND, GARY -
REGISTERED AGENT ADDRESS CHANGED 2019-03-28 8480 MANRESA AVENUE, JACKSONVILLE, FL 32244 -
CHANGE OF PRINCIPAL ADDRESS 2012-04-18 8480 MANRESA AVENUE, JACKSONVILLE, FL 32244 -
CHANGE OF MAILING ADDRESS 2012-04-18 8480 MANRESA AVENUE, JACKSONVILLE, FL 32244 -

Documents

Name Date
ANNUAL REPORT 2025-01-13
ANNUAL REPORT 2024-02-09
ANNUAL REPORT 2023-01-23
ANNUAL REPORT 2022-02-09
ANNUAL REPORT 2021-01-27
LC Amendment 2020-07-23
ANNUAL REPORT 2020-01-03
ANNUAL REPORT 2019-03-28
ANNUAL REPORT 2018-04-03
ANNUAL REPORT 2017-03-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339986200 0419700 2014-10-02 396 FOREST MEADOW LANE, JACKSONVILLE, FL, 32210
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-10-02
Emphasis L: FALL, P: FALL
Case Closed 2014-12-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-11-17
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-12-12
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about October 2, 2014, on the roof, an employee using a Ridgid pneumatic air stapler while installing vinyl components was not wearing safety glasses, exposing him to eye injuries. b. On or about October 2, 2014, on the ground floor, an employee was using a Ridgid skill saw while cutting vinyl components was not wearing safety glasses, exposing him to eye injuries.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-11-17
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-12-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about October 2, 2014, on the 7:12 pitch roof, an employee was installing vinyl along the soffit of the residential house without a fall protection system, exposing him to an 9 feet fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-11-17
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-12-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about October 2, 2014, the extension ladder used to access the roof did not extend 3 feet above the eave, exposing employees to a 9 feet fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-11-17
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-12-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about October 2, 2014, an employee on the roof, was using two 8-foot aluminum Louisiana stepladder with a plank stationed on the top rungs in order to install vinyl along the soffit of a residential house, exposing him to a 7 feet 8-inch fall hazard.
339487266 0419700 2013-11-13 6018 ROCKING HORSE COURT, JACKSONVILLE, FL, 32234
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-01-14
Emphasis L: FALL, P: FALL
Case Closed 2014-02-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-01-17
Current Penalty 1224.0
Initial Penalty 2040.0
Final Order 2014-01-28
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision of paragraph (b) of this section: a. On or about November 13, 2013, the second story window opening did not have a guardrail, exposing employees to a 13-foot fall hazard. b. On or about November 13, 2013, on a 4:12 pitch roof, an employee performing house wrap insulation work was not protected from a 9-foot, 6-inch fall hazard by the use of a fall protection system.

Date of last update: 01 Apr 2025

Sources: Florida Department of State