Entity Name: | COMPLETE ROOFING OF BREVARD LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
COMPLETE ROOFING OF BREVARD LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 13 Aug 2008 (17 years ago) |
Date of dissolution: | 22 Sep 2023 (a year ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 22 Sep 2023 (a year ago) |
Document Number: | L08000078080 |
FEI/EIN Number |
263178758
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 3545 N COURTENAY PARKWAY, MERRITT ISLAND, FL, 32954 |
Mail Address: | P.O. Box 542413, MERRITT ISLAND, FL, 32954, US |
ZIP code: | 32954 |
County: | Brevard |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SADOWSKY WALTER F | Managing Member | 3545 N COURTENAY PARKWAY, MERRITT ISLAND, FL, 32954 |
SADOWSKY WALTER F | Agent | 3545 N COURTENAY PARKWAY, MERRITT ISLAND, FL, 32954 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2023-09-22 | - | - |
REGISTERED AGENT NAME CHANGED | 2016-01-19 | SADOWSKY, WALTER FJR. | - |
REINSTATEMENT | 2016-01-19 | - | - |
CHANGE OF MAILING ADDRESS | 2016-01-19 | 3545 N COURTENAY PARKWAY, MERRITT ISLAND, FL 32954 | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2015-09-25 | - | - |
CANCEL ADM DISS/REV | 2009-10-14 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2009-09-25 | - | - |
CONVERSION | 2008-08-13 | - | CORPORATION WAS A CONVERSION RESULT. CONVERTING CORPORATION WAS P00000040675. CONVERSION NUMBER 500000089575 |
Name | Date |
---|---|
ANNUAL REPORT | 2022-03-20 |
ANNUAL REPORT | 2021-04-21 |
ANNUAL REPORT | 2020-01-16 |
ANNUAL REPORT | 2019-02-11 |
ANNUAL REPORT | 2018-01-30 |
ANNUAL REPORT | 2017-01-10 |
AMENDED ANNUAL REPORT | 2016-01-25 |
REINSTATEMENT | 2016-01-19 |
ANNUAL REPORT | 2014-04-25 |
ANNUAL REPORT | 2013-04-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339062069 | 0420600 | 2013-05-07 | 1377 OTTER AVE, MERRITT ISLAND, FL, 32952 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-05-30 |
Abatement Due Date | 2013-05-30 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-06-24 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) back of the house - employees were exposed to a fall of 11 feet while installing wood and installing peel and stick on a roof with a 8/12 slope, on or about 5/7/13. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2013-05-30 |
Abatement Due Date | 2013-07-17 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-06-24 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) back of the house - the employees were exposed to a fall of 11 feet while installing plywood and peel and stick on a roof with a 8/12 slope. The employer did not train the employees to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards, on or about 5/7/13. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-05-30 |
Abatement Due Date | 2013-05-30 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-06-24 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) back of the house - the employees were exposed to a fall of 11 feet, in that, they were using an extension ladder to access and egress the roof and the ladder extended approximately 1 1/2 feet above the landing, on or about 5/7/13. |