Search icon

M&W CONTRACTING LLC - Florida Company Profile

Company Details

Entity Name: M&W CONTRACTING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

M&W CONTRACTING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 14 Apr 2008 (17 years ago)
Date of dissolution: 25 Sep 2009 (15 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2009 (15 years ago)
Document Number: L08000037267
Address: 531 MANDALAY ROAD, JACKSONVILLE, FL, 32216
Mail Address: 531 MANDALAY ROAD, JACKSONVILLE, FL, 32216
ZIP code: 32216
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WILSON BRIAN Manager 2631 SETTLEMENT DRIVE, JACKSONVILLE, FL, 32226
MATHIS CAROL D Manager 531 MANDALAY RD, JACKSONVILLE, FL, 32216
MATHIS AARON D Manager 531 MANDALAY RD, JACKSONVILLE, FL, 32216
MATHIS AARON D Agent 531 MANDALAY RD, JACKSONVILLE, FL, 32216

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2009-09-25 - -

Documents

Name Date
Florida Limited Liability 2008-04-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340505437 0420600 2015-03-31 27270 SR56, WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-03-31
Emphasis L: FALL, P: FALL, L: FORKLIFT
Case Closed 2017-11-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2015-04-14
Abatement Due Date 2015-05-01
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-05-06
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a. In the man-basket, the safety guard on the Porter hand held grinder (Model PC60TAG) was missing, exposing employees to a struck-by hazard, on or about 3/31/2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02 IV
Issuance Date 2015-04-14
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-05-06
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use: a. On the forks of the Lull 6K-42 Telehandler Forklift, a fabricated man-basket was used to lift and support employees, on or about 3/31/2015. b. On the forks of the Lull 6K-42 Telehandler Forklift, a fabricated man-basket was used to lift and support employees, on or about 4/13/2015.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-04-14
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2015-05-06
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. In the man-basket, fall protection was not provided, exposing employees to a 15 foot fall hazard, on or about 3/31/2015.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260602 C01 VIII A
Issuance Date 2015-04-14
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2015-05-06
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(c)(1)(viii)(A): The safety platform was not firmly secured to the lifting carriage and/or forks: a. On the forks and lifting carriage of the Lull powered industrial truck, the man-basket was not secured, exposing employees to a 15 foot fall hazard, on or about 3/31/2015. b. On the forks and lifting carriage of the Lull powered industrial truck, the man-basket was not secured, exposing employees to a 15 foot fall hazard, on or about 4/13/2015.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2015-04-14
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-05-06
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a. On the top of the metal I-Beam framing, where a hole was being drilled, fall protection was not provided, exposing an employee to a 20 foot fall hazard, on or about 3/31/2015.
Citation ID 02001
Citaton Type Other
Standard Cited 19260102 A01
Issuance Date 2015-04-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-05-06
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On the top of the metal I-Beam framing, eye protection was not provided for an employee operating a hand held electric drill, exposing the employee to a struck by hazard, on or about 3/31/2015.
Citation ID 02002
Citaton Type Other
Standard Cited 19260403 B01
Issuance Date 2015-04-14
Abatement Due Date 2015-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-05-06
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a. In the man-basket, extension cords that were not inspected prior to use were worn and damaged, exposing employees to the hazard of contact with electrical current, on or about 3/31/2015.
Citation ID 02003
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2015-04-14
Abatement Due Date 2015-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-05-06
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a. In the man-basket, a flexible cord did not have a strain relief device connected at the female end of the extension cord, exposing employees to the hazard of contact with electrical current, on or about 3/31/2015.
Citation ID 02004
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2015-04-14
Abatement Due Date 2015-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-05-06
Nr Instances 5
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used: a. In the man-basket, damaged and worn flexible cords were used, exposing employees to the hazard of contact with electrical current, on or about 3/31/2015.

Date of last update: 02 Mar 2025

Sources: Florida Department of State