Entity Name: | GENTRY PRINTING COMPANY LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
GENTRY PRINTING COMPANY LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 24 Mar 2008 (17 years ago) |
Document Number: | L08000029898 |
FEI/EIN Number |
262247900
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2070 GENTRY ST., CLEARWATER, FL, 33765 |
Mail Address: | 2070 GENTRY ST., CLEARWATER, FL, 33765 |
ZIP code: | 33765 |
County: | Pinellas |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
CLAAR KEITH | Managing Member | 2070 GENTRY ST., CLEARWATER, FL, 33765 |
KELLY JASON | Managing Member | 2070 GENTRY ST., CLEARWATER, FL, 33765 |
KELLY JASON | Agent | 1301 ARDEN AVE., CLEARWATER, FL, 33765 |
Name | Date |
---|---|
ANNUAL REPORT | 2024-03-25 |
ANNUAL REPORT | 2023-04-21 |
ANNUAL REPORT | 2022-04-20 |
ANNUAL REPORT | 2021-04-27 |
ANNUAL REPORT | 2020-06-24 |
ANNUAL REPORT | 2019-04-26 |
ANNUAL REPORT | 2018-04-16 |
ANNUAL REPORT | 2017-04-03 |
ANNUAL REPORT | 2016-04-25 |
ANNUAL REPORT | 2015-04-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339813347 | 0420600 | 2014-06-17 | 2070 GENTRY STREET, CLEARWATER, FL, 33765 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100147 C01 |
Issuance Date | 2014-08-11 |
Abatement Due Date | 2014-09-05 |
Current Penalty | 800.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-09-02 |
Nr Instances | 1 |
Nr Exposed | 19 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) For the Gentry Printers facility as observed on or about 06/17/2014, employees performed maintenance on equipment such as, but not limited to, printing presses, stitcher, and folders. Maintenance included replacing of rollers, greasing machines, and cleaning filters. Hazardous energy existed in the form of 240VAC/480VAC and mechanical moving parts. Lockout of energy sources was not accomplished prior to performing maintenance. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100178 L01 I |
Issuance Date | 2014-08-11 |
Abatement Due Date | 2014-09-05 |
Current Penalty | 600.0 |
Initial Penalty | 1200.0 |
Final Order | 2014-09-02 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) For the Gentry Printing Company facility as observed on or about 06/17/2014, employees operated a Komatsu forklift to load and unload trucks. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2014-08-11 |
Abatement Due Date | 2014-09-12 |
Current Penalty | 800.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-09-02 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: For the Gentry Printers facility as observed on or about 06/17/2014 and 07/11/2014, employees were exposed to ingoing nip points from unguarded rollers: a) On the Komori Lithrone L540 press b) On the Polly 466 Press |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100242 B |
Issuance Date | 2014-08-11 |
Current Penalty | 850.0 |
Initial Penalty | 1700.0 |
Final Order | 2014-09-02 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) For the Gentry Printers facility as observed on or about 06/17/2014, employees in the press room used compressed air for cleaning purposes at a dead front pressure of 80 p.s.i. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2177507203 | 2020-04-15 | 0455 | PPP | 2070 Gentry Street, Clearwater, FL, 33765 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 03 Apr 2025
Sources: Florida Department of State