Entity Name: | RD MASONRY, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
RD MASONRY, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 11 Dec 2007 (17 years ago) |
Date of dissolution: | 24 Sep 2021 (4 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 24 Sep 2021 (4 years ago) |
Document Number: | L07000123298 |
FEI/EIN Number |
261556624
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 13118 Wexford Hollow Rd N, JACKSONVILLE, FL, 32224, US |
Mail Address: | 13118 Wexford Hollow Rd N, JACKSONVILLE, FL, 32224, US |
ZIP code: | 32224 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role |
---|---|
GUNSTER, YOAKLEY & STEWART, P.A. | Agent |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2021-09-24 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2020-03-30 | 13118 Wexford Hollow Rd N, JACKSONVILLE, FL 32224 | - |
CHANGE OF MAILING ADDRESS | 2020-03-30 | 13118 Wexford Hollow Rd N, JACKSONVILLE, FL 32224 | - |
REGISTERED AGENT ADDRESS CHANGED | 2015-04-03 | ONE ENTERPRISE, 225 WATER STREET, #1750, JACKSONVILLE, FL 32202 | - |
LC STMNT OF RA/RO CHG | 2015-04-03 | - | - |
REGISTERED AGENT NAME CHANGED | 2015-04-03 | GUNSTER, YOAKLEY, & STEWART, P.A. | - |
LC AMENDMENT | 2013-07-15 | - | - |
LC AMENDMENT | 2013-06-19 | - | - |
Name | Date |
---|---|
AMENDED ANNUAL REPORT | 2020-03-30 |
ANNUAL REPORT | 2020-03-16 |
ANNUAL REPORT | 2019-02-15 |
ANNUAL REPORT | 2018-03-13 |
ANNUAL REPORT | 2017-03-31 |
ANNUAL REPORT | 2016-04-18 |
CORLCRACHG | 2015-04-03 |
ANNUAL REPORT | 2015-02-25 |
ANNUAL REPORT | 2014-01-15 |
LC Amendment | 2013-07-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343625240 | 0419700 | 2018-11-28 | 1525 KINGSLEY AVE, ORANGE PARK, FL, 32073 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1403690 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1362529 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260451 B01 |
Issuance Date | 2019-01-16 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-02-12 |
Nr Instances | 2 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): 1. On or about November 28, 2018, at the northeast corner of the building, around stairway 2, on the 5th level of the scaffold, the platform had a 4-inch gap between the outermost plank and the upright post for the guardrail. 2. On or about November 28, 2018, at the south side of stairway 2, on the 5th level of the scaffold, angle planking was missing from the platform where the scaffold wrapped the stairway structure from the east face to the south face of the stairway. |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19260701 B |
Issuance Date | 2019-01-16 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-02-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: a. On or about November 28, 2018, at the block wall for elevator shafts 1 and 2, vertical reinforcing steel rods were not capped. |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-04-11 |
Emphasis | L: FALL |
Case Closed | 2017-04-20 |
Related Activity
Type | Complaint |
Activity Nr | 1200121 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1224278 |
Safety | Yes |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2011-12-13 |
Emphasis | S: POWERED IND VEHICLE, L: EISAOF, L: FORKLIFT, S: COMMERCIAL CONSTR |
Case Closed | 2011-12-13 |
Inspection Type | Referral |
Scope | Complete |
Safety/Health | Health |
Close Conference | 2010-10-15 |
Emphasis | N: SILICA, S: COMMERCIAL CONSTR, S: SILICA |
Case Closed | 2010-12-08 |
Related Activity
Type | Referral |
Activity Nr | 201359056 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100134 C02 I |
Issuance Date | 2010-12-02 |
Abatement Due Date | 2011-01-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 01 |