Search icon

TECH-ROCK LLC - Florida Company Profile

Company Details

Entity Name: TECH-ROCK LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

TECH-ROCK LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 21 Nov 2007 (17 years ago)
Document Number: L07000117224
FEI/EIN Number 331192424

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 22674 NE 117TH WAY, RAIFORD, FL, 32083
Mail Address: 22674 NE 117TH WAY, RAIFORD, FL, 32083
ZIP code: 32083
County: Union
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RUNNION ROBERT M Managing Member 22674 NE 117TH WAY, RAIFORD, FL, 32083
RUNNION DEBHILYN B Managing Member 22674 NE 117TH WAY, RAIFORD, FL, 32083
RUNNION ROBERT M Agent 22674 NE 117TH WAY, RAIFORD, FL, 32083

Documents

Name Date
ANNUAL REPORT 2025-01-11
ANNUAL REPORT 2024-01-12
ANNUAL REPORT 2023-01-24
ANNUAL REPORT 2022-01-11
ANNUAL REPORT 2021-04-16
ANNUAL REPORT 2020-02-12
ANNUAL REPORT 2019-02-11
ANNUAL REPORT 2018-01-15
ANNUAL REPORT 2017-02-11
ANNUAL REPORT 2016-03-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345107445 0419700 2021-01-20 16050 SHARK ROAD WEST, JACKSONVILLE, FL, 32226
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2021-05-24
Emphasis L: FALL
Case Closed 2023-07-18

Related Activity

Type Accident
Activity Nr 1722018

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2021-05-27
Current Penalty 3820.0
Initial Penalty 5461.0
Final Order 2021-06-14
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. At 16050 Shark Road West, Jacksonville, Florida: On or about January 19, 2021, and at times prior, an employee was exposed to an 11 feet, 9- inch fall hazard, in that; there were only two 19-inch wide planks installed between the end frame uprights of a 58-inch wide MetalTech scaffold.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2021-05-27
Current Penalty 11605.0
Initial Penalty 13653.0
Final Order 2021-06-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a. At 16050 Shark Road West, Jacksonville, Florida: On or about January 19, 2021, and at times prior, an employee was exposed to an 11 feet, 9-inch fall hazard, in that; the scaffold platform did not have guardrails installed or a personal fall arrest system in use.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2021-05-27
Abatement Due Date 2021-07-23
Current Penalty 2730.0
Initial Penalty 3901.0
Final Order 2021-06-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7):Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a. At 16050 Shark Road West, Jacksonville, Florida: On or about January 19, 2021, and at times prior, employees were exposed to fall and struck-by hazards from a scaffold system, in that; the scaffold system was erected without the supervision of a competent person, resulting in guardrails, cross-bracing, and diagonal bracing components not being installed on the equipment.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2021-05-27
Current Penalty 2730.0
Initial Penalty 3901.0
Final Order 2021-06-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2):Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. At 16050 Shark Road West, Jacksonville, Florida: On or about January 19, 2021, and at times prior, employees were exposed to fall and struck-by hazards, in that; a scaffold system was missing one set of vertical cross bracing on each level and a horizontal diagonal brace across the bottom.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2021-05-27
Abatement Due Date 2021-07-23
Current Penalty 2730.0
Initial Penalty 3901.0
Final Order 2021-06-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a):The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a. At 16050 Shark Road West, Jacksonville, Florida: On or about January 19, 2021, and at times prior, employees working from the scaffold platforms did not receive training from a person qualified to recognize hazards, such as, but not limited to, incomplete planking, bracing, guard rails and the procedures to minimize these hazards.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2021-05-27
Abatement Due Date 2021-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-06-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b):The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a. At 16050 Shark Road West, Jacksonville, Florida: On or about January 19, 2021, and at times prior, employees working from the scaffold platforms, did not receive training from a person who is qualified in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold system, to recognize hazards associated with scaffolds.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2021-05-27
Abatement Due Date 2021-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-06-14
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part: a. On or about January 19, 2021 the employer did not initiate and maintain a safety and health program which addressed the following basic elements: 1. Management Commitment and Leadership 2. Assignment of Responsibility 3. Identification and Control of Hazards 4. Training and Education 5. Hazard Analysis

Date of last update: 02 Apr 2025