Search icon

MIDSTATE CAULKING & CONSTRUCTION SERVICES, LLC - Florida Company Profile

Company Details

Entity Name: MIDSTATE CAULKING & CONSTRUCTION SERVICES, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

MIDSTATE CAULKING & CONSTRUCTION SERVICES, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 02 Jul 2007 (18 years ago)
Last Event: LC AMENDMENT
Event Date Filed: 26 Nov 2012 (12 years ago)
Document Number: L07000069331
FEI/EIN Number 510641180

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1600 Kelley Ave, KISSIMMEE, FL, 34744, US
Mail Address: 1600 Kelley Ave, KISSIMMEE, FL, 34744, US
ZIP code: 34744
County: Osceola
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CLEMENT BRENDA Manager 1600 Kelley Ave, KISSIMMEE, FL, 34744
CLEMENT LEON Manager 1600 Kelley Ave, KISSIMMEE, FL, 34744
CLEMENT LEON C Agent 4958 LAKE CECILE DR, KISSIMMEE, FL, 34746

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2017-02-15 1600 Kelley Ave, KISSIMMEE, FL 34744 -
CHANGE OF MAILING ADDRESS 2017-02-15 1600 Kelley Ave, KISSIMMEE, FL 34744 -
LC AMENDMENT 2012-11-26 - -
REGISTERED AGENT ADDRESS CHANGED 2012-01-13 4958 LAKE CECILE DR, KISSIMMEE, FL 34746 -
REGISTERED AGENT NAME CHANGED 2012-01-13 CLEMENT, LEON CJR -

Documents

Name Date
ANNUAL REPORT 2025-02-04
ANNUAL REPORT 2024-01-04
ANNUAL REPORT 2023-01-06
ANNUAL REPORT 2022-01-12
ANNUAL REPORT 2021-01-17
ANNUAL REPORT 2020-01-12
ANNUAL REPORT 2019-01-13
ANNUAL REPORT 2018-01-16
ANNUAL REPORT 2017-02-15
ANNUAL REPORT 2016-01-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347179848 0419730 2023-12-21 5447 ONATE LANE CVS STORE # 11516, MELBOURNE, FL, 32901
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-12-21
Emphasis N: CTARGET, P: FALL, N: FALL
Case Closed 2024-03-21

Related Activity

Type Inspection
Activity Nr 1727484
Safety Yes
346033970 0419730 2022-06-22 510 ORLANDO AVE, WINTER PARK, FL, 32789
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2022-06-22
Emphasis L: FALL, N: COVID-19
Case Closed 2022-12-14

Related Activity

Type Inspection
Activity Nr 1603389
Safety Yes
Type Inspection
Activity Nr 1603546
Safety Yes
Type Inspection
Activity Nr 1603410
Safety Yes
345694566 0420600 2021-12-10 10041 U.S. 441 N, LEESBURG, FL, 34788
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2021-12-10
Emphasis L: FALL
Case Closed 2022-03-01

Related Activity

Type Inspection
Activity Nr 1569455
Safety Yes
339370447 0419700 2013-08-21 1749 APALACHEE PARKWAY, TALLAHASSEE, FL, 32304
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-08-22
Emphasis L: FALL, P: FALL
Case Closed 2013-11-26

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-09-20
Current Penalty 2100.0
Initial Penalty 2800.0
Final Order 2013-10-18
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about August 21, 2013, northeast side of the buiding, the second and third levels of the scaffold were not fully planked, exposing employees of Avery Enterprises, Inc. to 20 feet fall hazard. b. On or about August 21, 2013, north side of the building, the second level of the scaffold was not fully planked, exposing employees of Midstate Caulking & Construction Services, Inc. to a 14 feet fall hazard. Abatement Certification and Documentation are not required
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 H02 II
Issuance Date 2013-09-20
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2013-10-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a. On or about August 21, 2013, toeboards were not erected along the edge of platforms when employees were working with a tile machine and tiles, exposing employees underneath to head injuries.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2013-09-20
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-10-18
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. On or about August 21, 2013, northeast side of the building, two employees of Avery Enterprises, Inc. were cutting and installing tile from the top level of a scaffold system. They were not protected from falling 20 feet by the use of a guardrail system, safety net system or personal fall arrest system. b. On or about August 21, 2013, north side of the building, employees of Midstate Caulking & Construction Services, Inc., were plastering the exterior of the building. They were not protected from falling 14 feet by the use of a guardrail system, safety net system or personal fall arrest system. Abatement Certification and Documentation are not required
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 G04 IV
Issuance Date 2013-09-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-10-18
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface: a. On or about August 21, 2013, northeast side of the building, the 3 buck high scaffold system were missing endrails and midrails along the top level of the scaffold system, exposing employees to a 20 feet fall hazard. Abatement Certification and Documentation are not required