Search icon

J S M MASONRY, LLC - Florida Company Profile

Company Details

Entity Name: J S M MASONRY, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

J S M MASONRY, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 04 May 2007 (18 years ago)
Date of dissolution: 25 Sep 2009 (16 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2009 (16 years ago)
Document Number: L07000047756
FEI/EIN Number 770684391

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 107 POSEY LANE, CRESCENT CITY, FL, 32112
Mail Address: PO BOX 86, CRESCENT CITY, FL, 32112
ZIP code: 32112
County: Putnam
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MENDOZA JESUS S Manager 107 POSEY LANE, CRESCENT CITY, FL, 32112
HAENFLER JAMES A Agent 20 N SUMMIT STREET, CRESCENT CITY, FL, 32112

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2009-09-25 - -

Documents

Name Date
ANNUAL REPORT 2008-07-14
Florida Limited Liability 2007-05-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341293660 0419700 2016-03-02 1234 BEACH BLVD., JACKSONVILLE, FL, 32099
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-03-02
Emphasis L: FALL, P: FALL
Case Closed 2016-06-16

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C01
Issuance Date 2016-05-06
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-06-01
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph: a. On or about March 2, 2016, on the east side of the building, employees were working on a scaffold 20 feet 8 inches high that was not tied into the structure.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-05-06
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-06-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. On or about March 2, 2016, the scaffold platform was not fully planked or decked between the front uprights and the guardrail supports, exposing an employee to a 14 feet fall hazard.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-05-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a. On or about March 2, 2016, on the south side of the scaffold, an employee was climbing the rails of the scaffold being exposed to a 20.8 feet fall hazard.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-05-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about March 2, 2016, on the south side of the structure, an employee working on a scaffold 14 feet high was not protected by a guardrail, exposing employees to a 25 feet fall hazard
Citation ID 01005
Citaton Type Serious
Standard Cited 19260502 B02
Issuance Date 2016-05-06
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-06-01
Nr Instances 2
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. a. On or about March 2, 2016, on the north side of the structure, employees were working on a scaffold that was missing the mid-rail in two sections of the scaffold, exposing the employees to a 20.8 feet fall hazard.