Search icon

LABRAS CONSTRUCTION LLC - Florida Company Profile

Company Details

Entity Name: LABRAS CONSTRUCTION LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

LABRAS CONSTRUCTION LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 28 Mar 2007 (18 years ago)
Document Number: L07000033638
FEI/EIN Number 208679768

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1165 STANTON SHADOW LN, APOPKA, FL, 32712
Mail Address: 1165 STANTON SHADOW LN, APOPKA, FL, 32712
ZIP code: 32712
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LABRAS RIGOBERTO Managing Member 1165 STANTON SHADOW LN, APOPKA, FL, 32712
LABRAS RIGOBERTO Agent 1165 STANTON SHADOW LN, APOPKA, FL, 32712
LABRAS JOEL Manager 1165 STANTON SHADOW LN, APOPKA, FL, 32712

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2020-06-16 LABRAS, RIGOBERTO -
REGISTERED AGENT ADDRESS CHANGED 2008-06-12 1165 STANTON SHADOW LN, APOPKA, FL 32712 -

Documents

Name Date
ANNUAL REPORT 2024-04-23
ANNUAL REPORT 2023-04-25
ANNUAL REPORT 2022-02-23
ANNUAL REPORT 2021-04-21
ANNUAL REPORT 2020-06-16
ANNUAL REPORT 2019-04-15
ANNUAL REPORT 2018-04-18
ANNUAL REPORT 2017-04-25
ANNUAL REPORT 2016-03-09
ANNUAL REPORT 2015-04-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341302073 0419700 2016-03-03 73 APIAN WAY, ORMOND BEACH, FL, 32174
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-03-03
Emphasis L: FALL, P: FALL
Case Closed 2017-07-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-05-03
Current Penalty 3773.0
Initial Penalty 5390.0
Final Order 2016-05-25
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On or about March 3, 2016, employees setting trusses were not protected from falling up to 17 feet 4 inches by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection method.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2016-05-03
Abatement Due Date 2016-05-11
Current Penalty 2695.0
Initial Penalty 3850.0
Final Order 2016-05-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about March 3, 2016, employees were using the top step of a 6-foot step ladder to gain access and exit from the trusses. They were being exposed to a 6 feet fall hazard.
340212893 0420600 2015-01-28 425 FOUNTAIN PARK BLVD, LAKE MARY, FL, 32746
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-01-28
Emphasis P: CTARGET, N: CTARGET, L: EISAX, L: EISAOF
Case Closed 2015-07-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 A08
Issuance Date 2015-02-27
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2015-03-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(a)(8): A metal spreader or locking device was not provided on each stepladder to hold the front and back sections in an open position when the ladder was being used: (a). At Lot-105 on Trapani Loop the stepladder that was being used by an employee securing a subfloor was not opened and locked to prevent a fall hazard, on or about January 28, 2015.
335703385 0420600 2012-08-10 FOUNTAIN PARKE BOULVARD, LAKE MARY, FL, 32746
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-08-13
Emphasis L: EISAOF, L: EISAX, L: FALL
Case Closed 2013-11-26

Related Activity

Type Inspection
Activity Nr 570121
Safety Yes
Type Inspection
Activity Nr 570078
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2012-09-21
Current Penalty 734.4
Initial Penalty 1224.0
Final Order 2012-09-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a. On or about August 13, 2012, an employee using a pneumatic nail gun to install floor joists was not wearing safety glasses or face shield to protect against being struck-by debris or projectiles.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2012-09-21
Current Penalty 918.0
Initial Penalty 1530.0
Final Order 2012-09-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a. On or about August 13, 2012, reinforced steel rod was not capped or guarded to protect employees working overhead from impalement.

Date of last update: 03 Apr 2025

Sources: Florida Department of State