Entity Name: | A GOOD MAN AROUND THE HOUSE LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
A GOOD MAN AROUND THE HOUSE LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 20 Feb 2007 (18 years ago) |
Last Event: | CANCEL ADM DISS/REV |
Event Date Filed: | 13 Oct 2008 (17 years ago) |
Document Number: | L07000018998 |
FEI/EIN Number |
352362167
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 6730 NW 1ST AVE, OCALA, FL, 34475 |
Mail Address: | P.O. BOX 6510, OCALA, FL, 34478 |
ZIP code: | 34475 |
County: | Marion |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
LEA THOMAS RIII | President | 6730 NW 1ST AVE, OCALA, FL, 34475 |
LEA THOMAS RIII | Agent | 6730 NW 1ST AVE, OCALA, FL, 34475 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G12000101267 | AGM ROOFING | ACTIVE | 2012-10-17 | 2027-12-31 | - | 6730 NW 1ST AVE, OCALA, FL, 34475 |
G12000101277 | AGM TREE SERVICE | ACTIVE | 2012-10-17 | 2027-12-31 | - | 6730 NW 1ST AVE, OCALA, FL, 34475 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2015-04-20 | LEA, THOMAS R, III | - |
REGISTERED AGENT ADDRESS CHANGED | 2015-04-20 | 6730 NW 1ST AVE, OCALA, FL 34475 | - |
CHANGE OF PRINCIPAL ADDRESS | 2009-04-07 | 6730 NW 1ST AVE, OCALA, FL 34475 | - |
CANCEL ADM DISS/REV | 2008-10-13 | - | - |
CHANGE OF MAILING ADDRESS | 2008-10-13 | 6730 NW 1ST AVE, OCALA, FL 34475 | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2008-09-26 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-02 |
ANNUAL REPORT | 2023-04-28 |
ANNUAL REPORT | 2022-04-20 |
ANNUAL REPORT | 2021-04-07 |
ANNUAL REPORT | 2020-03-25 |
ANNUAL REPORT | 2019-04-11 |
ANNUAL REPORT | 2018-04-04 |
ANNUAL REPORT | 2017-02-22 |
ANNUAL REPORT | 2016-03-17 |
ANNUAL REPORT | 2015-04-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343777827 | 0419700 | 2019-02-12 | 710 HWY 98, MEXICO BEACH, FL, 32456 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2019-03-15 |
Current Penalty | 2652.0 |
Initial Penalty | 5304.0 |
Final Order | 2019-04-08 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On or about February 12, 2019, on the 5:12 pitch second-story roof, an employee re-installing roofing paper was exposed to 22 feet to 27 feet fall hazards from the eaves and raked edges of the roof in that he was not protected by a fall protection system. b. On or about February 12, 2019, on the 5:12 pitch roof above the front porch, three employees were exposed to an 11 feet fall hazard in that they were not protected by a fall protection system. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2019-03-15 |
Current Penalty | 1515.5 |
Initial Penalty | 3031.0 |
Final Order | 2019-04-08 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about February 12, 2019, at the front porch eave, the roof access ladder to the front porch roof was not extended 3 feet above the eave, exposing employees to an 11.7 feet fall hazard. b. On or about February 12, 2019, on the 5:12 pitch porch roof, the roof access ladder to the second-story roof was not extended 3 feet above the roof edge of the upper landing surface, exposing an employee to a 6 feet fall hazard to the lower roof. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2019-02-12 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2023-01-25 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-03-15 |
Current Penalty | 3182.4 |
Initial Penalty | 5304.0 |
Final Order | 2019-04-08 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about February 12, 2019, on the 4:12 roof over the garage, two roofing employees were exposed to an 8 feet to 12 feet fall hazard from the eaves and raked edges in that they were not protected by a fall protection system. b. On or about February 12, 2019, on the 6:12 pitch second floor roof, two roofing employees were exposed to an 18 feet fall hazard from the eaves in that they were not protected by a fall protection system. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6291357709 | 2020-05-01 | 0491 | PPP | 6730 NW 1ST AVE, OCALA, FL, 34475-1265 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|