Search icon

PARADISE BUILDERS, LLC - Florida Company Profile

Company Details

Entity Name: PARADISE BUILDERS, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

PARADISE BUILDERS, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 08 Nov 2006 (18 years ago)
Date of dissolution: 14 Sep 2007 (18 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 14 Sep 2007 (18 years ago)
Document Number: L06000108538
Address: 1351 SCARLET OAK CIR., VERO BEACH, FL, 32966
Mail Address: 1351 SCARLET OAK CIR., VERO BEACH, FL, 32966
ZIP code: 32966
County: Indian River
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CHARLIE HOSKINS Manager 1342 SCARLETT OAK CIR, VERO BEACH, FL, 32966
HOSKINS CHARLIE Agent 1342 SCARLETT OAK CIR, VERO BEACH, FL, 32966

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2007-09-14 - -
LC NAME CHANGE 2007-02-09 PARADISE BUILDERS, LLC -
CHANGE OF PRINCIPAL ADDRESS 2007-02-09 1351 SCARLET OAK CIR., VERO BEACH, FL 32966 -
CHANGE OF MAILING ADDRESS 2007-02-09 1351 SCARLET OAK CIR., VERO BEACH, FL 32966 -

Documents

Name Date
LC Name Change 2007-02-09
Florida Limited Liability 2006-11-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339509739 0419700 2013-12-02 11 BRIDGEWAY LANE LOT #1, WATERSOUND, FL, 32413
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-12-02
Emphasis L: FALL
Case Closed 2016-08-17

Related Activity

Type Complaint
Activity Nr 863371
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-02-25
Abatement Due Date 2014-03-03
Current Penalty 2000.0
Initial Penalty 2400.0
Final Order 2014-04-18
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about December 2, 2013, inside a house, employees working beneath employees installing trim were not wearing hard hats, exposing themselves to the hazard of being struck by falling debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260304 D
Issuance Date 2014-02-25
Abatement Due Date 2014-03-03
Current Penalty 700.0
Initial Penalty 1600.0
Final Order 2014-04-18
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe: a. On or about December 2, 2013, inside a house, employees installing trim to the ceilings and walls were using a 10 inch table saw that did not have an upper guard over the blade, exposing themselves to the hazard of an amputation.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-02-25
Abatement Due Date 2014-03-03
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as follows: a. On or about December 2, 2013, the south east side of the house, employees installing trim to the ceilings and walls were using a scaffold that was not fully planked leaving a 3 feet 2 inch opening, exposing themselves to an 18 feet fall hazard.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-02-25
Abatement Due Date 2014-03-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-18
Nr Instances 3
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a. On or about December 2, 2013, inside a house on the north west side employees installing trim to the ceilings and walls were using 2 by 8 inch wood planks as scaffold, exposing employees to a 19 feet 9 inch fall hazard. b. On or about December 2, 2013, inside a house on the second level on the north east side employees installing trim to the ceilings and walls were using 2 by 8 inch wood planks as scaffold, exposing employees to a 12 feet 6 inch fall hazard. c. On or about December 2, 2013, inside a house on the second level on the north east side employees installing trim to the ceilings and walls were using 2 by 8 inch wood planks as scaffold, exposing employees to a 12 feet 6 inch fall hazard.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260502 D06 I
Issuance Date 2014-02-25
Abatement Due Date 2014-03-03
Current Penalty 2000.0
Initial Penalty 7000.0
Final Order 2014-04-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(6)(i): Snaphooks were engaged directly to webbing or wire rope: a. On or about December 2, 2013, inside of the house, employees installing trim to the ceilings and walls were using a vertical line that was engaged directly with the snaphook, exposing themselves to a 19 feet 9 inch fall hazard.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260502 D11
Issuance Date 2014-02-25
Abatement Due Date 2014-03-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded: a. On or about December 2, 2013, inside of the house, employees installing trim to the ceilings and walls were using a vertical line that was not protected from sharp edges and abrasions, exposing themselves to a 19 feet 9 inch fall hazard.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2014-02-25
Abatement Due Date 2014-03-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee: a. On or about December 2, 2013, inside of the house, employees installing trim to the ceilings and walls were using a vertical line that was anchored to an upper vertical frame, exposing themselves to a 19 feet 9 inch fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2014-02-25
Abatement Due Date 2014-03-21
Current Penalty 0.0
Initial Penalty 400.0
Final Order 2014-04-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about December 2, 2013, inside of the house, employees installing trim to the ceilings and walls were using carpenter's scaffolding, mobil scafflods, and personal fall arrest equipment that was not adequate for the job, exposing themselves to fall hazards up to 19 feet 9 inch.