Entity Name: | TI-CON ROOFING, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
TI-CON ROOFING, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 07 Sep 2006 (19 years ago) |
Last Event: | LC AMENDMENT |
Event Date Filed: | 30 Mar 2009 (16 years ago) |
Document Number: | L06000088013 |
FEI/EIN Number |
205504888
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1965 TRANQUILITY LANE, TITUSVILLE, FL, 32796, UN |
Mail Address: | 1965 TRANQUILITY LANE, TITUSVILLE, FL, 32796, UN |
ZIP code: | 32796 |
County: | Brevard |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
HUMAN DON D | Manager | 1965 TRANQUILITY LANE, TITUSVILLE, FL, 32796 |
HUMAN KATHRYN J | Manager | 1965 TRANQUILITY LANE, TITUSVILLE, FL, 32796 |
HUMAN DON D | Agent | 1965 TRANQUILITY LANE, TITUSVILLE, FL, 32796 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2012-04-04 | 1965 TRANQUILITY LANE, TITUSVILLE, FL 32796 UN | - |
CHANGE OF MAILING ADDRESS | 2012-04-04 | 1965 TRANQUILITY LANE, TITUSVILLE, FL 32796 UN | - |
LC AMENDMENT | 2009-03-30 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-14 |
ANNUAL REPORT | 2024-01-16 |
ANNUAL REPORT | 2023-01-26 |
ANNUAL REPORT | 2022-01-23 |
ANNUAL REPORT | 2021-01-29 |
ANNUAL REPORT | 2020-06-07 |
ANNUAL REPORT | 2019-04-03 |
ANNUAL REPORT | 2018-04-10 |
ANNUAL REPORT | 2017-04-27 |
ANNUAL REPORT | 2016-04-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346951734 | 0419730 | 2023-08-31 | 1674 S PARK AVE., TITUSVILLE, FL, 32780 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1695157 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260020 B02 |
Issuance Date | 2024-02-07 |
Abatement Due Date | 2024-02-27 |
Current Penalty | 3387.3 |
Initial Penalty | 4839.0 |
Final Order | 2024-03-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 1926.20(b)(2) The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person (i.e., a person who is capable of identifying exis(a)(LOCATION)(IDENTIFY THE HAZARDOUS CONDITION AND THE DEFICIENT ACTION) a) On or about 8/29/2023, at 1674 S Park Ave, Titusville, FL: employees and subcontractor employees were exposed to fall hazards of up to approximately 18 feet when conducting roofing work on a flat roof of a two-story house without fall protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-02-07 |
Current Penalty | 2419.9 |
Initial Penalty | 3457.0 |
Final Order | 2024-03-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 8/29/2023, at 1674 S Park Ave, Titusville, FL: employees and subcontractor used an aluminum ladder that only extended approximately 18 inches past the landing surface to access the 18-foot-high roof, exposing employees to fall hazards. b) On or about 8/31/2023, at 1674 S Park Ave, Titusville, FL: subcontractor employees used an aluminum extension ladder that only extended approximately 28 inches past the landing surface to access the 18-foot-high roof, exposing employees to fall hazards. |
Date of last update: 01 Apr 2025
Sources: Florida Department of State